본문 바로가기
KERD
논문KCI 등재

Anterior Chamber Measurements by Pentacam and AS-OCT in Eyes With Normal Open Angles

2

조회

0

다운로드

6

인용

0

참고문헌

키워드

주제분류안과학

초록

Purpose: To assess the reproducibility and agreement of anterior chamber measurements between the Pentacam (PTC) and the Anterior segment optical coherence tomography (AOCT) in normal healthy eyes with open angle. Methods: Prospective cross-sectional comparative case series. A total of 162 eyes of 81 healthy volunteers with normal open angle were included in this study. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Intra-observer variability and inter-methods agreement of both instruments for ACA and ACD were evaluated. Results: Values of temporal and nasal ACA measured by two instruments were similar, and the results of ACD were also not significantly different between modalities (p>0.01). ACA and ACD measurements by PTC and AOCT showed good intra-observer and inter-method agreements (all >0.9). Conclusions: PTC and AOCT are presumed to be very useful for the anterior chamber angle examination. They may provide good images and quantitative data about the angle structures including ACA and ACD.

Abstract

Purpose: To assess the reproducibility and agreement of anterior chamber measurements between the Pentacam (PTC) and the Anterior segment optical coherence tomography (AOCT) in normal healthy eyes with open angle. Methods: Prospective cross-sectional comparative case series. A total of 162 eyes of 81 healthy volunteers with normal open angle were included in this study. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Intra-observer variability and inter-methods agreement of both instruments for ACA and ACD were evaluated. Results: Values of temporal and nasal ACA measured by two instruments were similar, and the results of ACD were also not significantly different between modalities (p>0.01). ACA and ACD measurements by PTC and AOCT showed good intra-observer and inter-method agreements (all >0.9). Conclusions: PTC and AOCT are presumed to be very useful for the anterior chamber angle examination. They may provide good images and quantitative data about the angle structures including ACA and ACD.

참고문헌 (15)

  1. Bonomi L, "Epidemiology of Angle-closure Glaucoma; Prevalence, Clinical Types, and Association with Peripheral Anterior Chamber Depth in the Egna-Neumarkt Galucoma Study", Opthalmology, 107, pp.998~1003 (2000)
  2. Foster PJ, "Glaucoma in China-how big is the problem?", Br J Ophthalmol, 85, pp.1271~1272 (2001)
  3. Alsbrik PH, "Anterior chamber depth and primary angle-closure glaucoma. I. An epidemiologic study in Greenland Eskimos", Acta Ophthalmol (Copenh), 53, pp.89~104 (1975)
  4. Chew PT, "Primary angle-closure glaucoma in Asia", J Glaucoma, 10, pp.S7~8 (2001)
  5. Dandona L, "Angle-closure glaucoma in an urban population in southern India. The Andhra Pradesh eye disease study", Ophthalmology, 107, pp.1710~6 (2000)
  6. Radhakrishnan S, "Comparison of Optical Coherence Tomography and Ultrasound Biomicroscopy for Detection of Narrow Anterior Chamber Angles", Arch Ophthalmol, 123, pp.1053~9 (2005)
  7. Radhakrishnan S, "Optical coherence tomography imaging of the anterior chamber angle", Ophthalmol Clin N Am, 18, pp.375~81 (2005)
  8. Foster PJ, "Detection of gonioscopically occludable angles and primary angle closure glaucoma by estimation of limbal chamber depth in Asians: modified grading scheme", Br J Ophthalmol, 84, pp.186~92 (2000)
  9. Foster PJ, "The definition and classification of glaucoma in prevalence surveys", Br J Ophthalmol, 86, pp.238~42 (2002)
  10. Friedman DS, "Who needs an iridotomy?", Br J Ophthalmol, 85, pp.1019~21 (2001)
  11. Lackner B, "Validity and Repeatability of Anterior Chamber Depth Measurements With Pentacam and Orbscan", Optom Vis Sci, 82, pp.858~61 (2005)
  12. Bland JM, "Statistical methods for assessing agreement between two methods of clinical measurement", Lancet, 1, pp.307~10 (1986)
  13. Reddy AR, "Comparative estimation of anterior chamber depth by ultrasonography, Orbscan II, and IOLMaster", J Cataract Refract Surg, 30, pp.1268~71 (2004)
  14. Koranyi G, "Anterior chamber depth measurement: a-scan versus optical methods", J Cataract Refract Surg, 28, pp.243~7 (2002)
  15. Buehl W, "Comparison of three methods of measuring corneal thickness and anterior chamber depth", Am J Ophthalmol, 141, pp.7~12 (2006)

관련 논문AI추천

Changes in Anterior Chamber Configuration after Cataract Surgery as Measured by Anterior Segment Optical Coherence Tomography김동명, 김태우, Ki Ho Park, Martha Kim대한안과학회 · Korean Journal of Ophthalmology2011 · 제25권 제2호Anterior Chamber Configuration Changes after Cataract Surgery in Eyes with Glaucoma김동명, 김태우, 박기호, 김마르다대한안과학회 · Korean Journal of Ophthalmology2012 · 제26권 제2호Laser Peripheral Iridotomy with Iridoplasty in Primary Angle Closure Suspect: Anterior Chamber Analysis by PentacamJaewan Choi, Jin Young Choi, Jong Rak Lee,, Yeon-Deok Kim대한안과학회 · Korean Journal of Ophthalmology2011 · 제25권 제4호Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography김응권, 김태임, 류소영, 서경률, 윤숙현, 전익현대한안과학회 · Korean Journal of Ophthalmology2022 · 제36권 제3호Clinical and Anterior Segment Anatomical Features in Primary Angle Closure Subgroups Based on Configurations of Iris Root InsertionJi Wook Hong, Jong Eun Lee, Kyung Rim Sung, Sung Cheol Yun대한안과학회 · Korean Journal of Ophthalmology2016 · 제30권 제3호Anterior Segment Parameters Using Pentacam and Prediction of Corneal Endothelial Cell Loss after Cataract Surgery김만수, 나태윤, 장화석, 조양경, 지동현, 최진아, Hyunkyung Kim대한안과학회 · Korean Journal of Ophthalmology2010 · 제24권 제5호

이 간행물의 다른 논문 (14건)