Purpose: To evaluate the changes in anterior chamber depth (ACD) and angle width induced by phacoemulsification and intraocular lens (IOL) implantation in normal eyes using anterior segment optical coherence tomography (AS-OCT). Methods: Forty-five eyes (45 patients) underwent AS-OCT imaging to evaluate anterior chamber configuration before and 2 days after phacoemulsification and IOL implantation. We analyzed the central ACD and angle width using different methods: anterior chamber angle (ACA), trabecular-iris angle (TIA), angle opening distance (AOD), and trabecular iris surface area (TISA) in the nasal and temporal quadrants. Comparison between preoperative and postoperative measurement was done using paired t-tests and each of the angle parameters was analyzed with Pearson correlation testing. Subgroup analyses according to the IOL and axial length were performed with a general multivariate linear model adjusted for age. Results: Before surgery, the mean anterior chamber angle widths were 23.21 ± 6.70° in the nasal quadrant and 24.89 ± 7.66° in the temporal quadrant. The mean central ACD was 2.75 ± 0.43 mm. After phacoemulsification and IOL implantation, the anterior chamber angle width increased significantly to 35.16 ± 4.65° in the nasal quadrant (p = 0.001) and 36.03 ± 4.86° in the temporal quadrant (p = 0.001). Also, central ACD increased to 4.14 ±0.31 mm (p = 0.001). AOD, TISA, and TIA increased significantly after cataract surgery and showed positive correlation with ACA. Conclusions: After cataract surgery, the ACD and angle width significantly increased in eyes with cataract. AS-OCT is a good method for obtaining quantitative data regarding anterior chamber configuration.

Abstract

Purpose: To evaluate the changes in anterior chamber depth (ACD) and angle width induced by phacoemulsification and intraocular lens (IOL) implantation in normal eyes using anterior segment optical coherence tomography (AS-OCT). Methods: Forty-five eyes (45 patients) underwent AS-OCT imaging to evaluate anterior chamber configuration before and 2 days after phacoemulsification and IOL implantation. We analyzed the central ACD and angle width using different methods: anterior chamber angle (ACA), trabecular-iris angle (TIA), angle opening distance (AOD), and trabecular iris surface area (TISA) in the nasal and temporal quadrants. Comparison between preoperative and postoperative measurement was done using paired t-tests and each of the angle parameters was analyzed with Pearson correlation testing. Subgroup analyses according to the IOL and axial length were performed with a general multivariate linear model adjusted for age. Results: Before surgery, the mean anterior chamber angle widths were 23.21 ± 6.70° in the nasal quadrant and 24.89 ± 7.66° in the temporal quadrant. The mean central ACD was 2.75 ± 0.43 mm. After phacoemulsification and IOL implantation, the anterior chamber angle width increased significantly to 35.16 ± 4.65° in the nasal quadrant (p = 0.001) and 36.03 ± 4.86° in the temporal quadrant (p = 0.001). Also, central ACD increased to 4.14 ±0.31 mm (p = 0.001). AOD, TISA, and TIA increased significantly after cataract surgery and showed positive correlation with ACA. Conclusions: After cataract surgery, the ACD and angle width significantly increased in eyes with cataract. AS-OCT is a good method for obtaining quantitative data regarding anterior chamber configuration.

참고문헌 (36)

  1. Boker T, "Anterior chamber angle biometry:a comparison of Scheimpflug photography and ultrasound biomicroscopy", Ophthalmic Res,27 Suppl, 1, pp.104~109 (1995)
  2. Dada T, "Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment", J Cataract Refract Surg, 33, pp.837~840 (2007)
  3. Kucumen RB, "Anterior segment optical coherence tomography measurement of anterior chamber depth and angle changes after phacoemulsification and intraocular lens implantation", J Cataract Refract Surg, 34, pp.1694~1698 (2008)
  4. Lam AK, "Intra-observer and inter-observer repeatability of anterior eye segment analysis system(EAS-1000)in anterior chamber configuration", Ophthalmic Physiol Opt, 22, pp.552~559 (2002)
  5. Memarzadeh F, "Optical coherence tomography assessment of angle anatomy changes after cataract surgery", Am J Ophthalmol, 144, pp.464~465 (2007)
  6. Pavlin CJ, "Plateau iris syndrome:changes in angle opening associated with dark,light,and pilocarpine administration", Am J Ophthalmol, 128, pp.288~291 (1999)
  7. Pavlin CJ, "Ultrasound biomicroscopy in plateau iris syndrome", Am J Ophthalmol, 113, pp.390~395 (1992)
  8. Pavlin CJ, "Subsurface ultrasound microscopic imaging of the intact eye", Ophthalmology, 97, pp.244~250 (1990)
  9. Richards DW, "A method for improved biometry of the anterior chamber with a Scheimpflug technique", Invest Ophthalmol Vis Sci, 29, pp.1826~1835 (1988)
  10. Sakuma T, "Appositional angle closure in eyes with narrow angles:an ultrasound biomicroscopic study", J Glaucoma, 6, pp.165~169 (1997)
  11. Shibata T, "Quantitative chamber angle measurement utilizing image-processing techniques", Ophthalmic Res,22 Suppl, 1, pp.81~84 (1990)
  12. Nolan W, "Anterior segment imaging:ultrasound biomicroscopy and anterior segment optical coherence tomography", Curr Opin Ophthalmol, 19, pp.115~121 (2008)
  13. Radhakrishnan S, "Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles", Arch Ophthalmol, 123, pp.1053~1059 (2005)
  14. Radhakrishnan S, "Optical coherence tomography imaging of the anterior chamber angle", Ophthalmol Clin North Am, 18, pp.375~381 (2005)
  15. Nolan W, "Anterior segment imaging:identifying the landmarks", Br J Ophthalmol, 92, pp.1575~1576 (2008)
  16. Radhakrishnan S, "Real-time optical coherence tomography of the anterior segment at 1310 nm", Arch Ophthalmol, 119, pp.1179~1185 (2001)
  17. Lee R, "Anterior segment optical coherence tomography:non-contact high resolution imaging of the anterior chamber", Tech Ophthalmol, 4, pp.120~127 (2006)
  18. Li H, "Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography", Br J Ophthalmol, 91, pp.1490~1492 (2007)
  19. Mohamed S, "Repeatability and reproducibility of pachymetric mapping with Visante anterior segment-optical coherence tomography", Invest Ophthalmol Vis Sci, 48, pp.5499~5504 (2007)
  20. Muller M, "Anterior chamber angle measurement with optical coherence tomography:intraobserver and interobserver variability", J Cataract Refract Surg, 32, pp.1803~1808 (2006)
  21. Radhakrishnan S, "Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography", Invest Ophthalmol Vis Sci, 48, pp.3683~3688 (2007)
  22. Hayashi K, "Changes in anterior chamber angle width and depth after intraocular lens implantation in eyes with glaucoma", Ophthalmology, 107, pp.698~703 (2000)
  23. Nolan WP, "Changes in angle configuration after phacoemulsification measured by anterior segment optical coherence tomography", J Glaucoma, 17, pp.455~459 (2008)
  24. Nonaka A, "Angle widening and alteration of ciliary process configuration after cataract surgery for primary angle closure", Ophthalmology, 113, pp.437~441 (2006)
  25. Pereira FA, "Ultrasound biomicroscopic study of anterior segment changes after phacoemulsification and foldable intraocular lens implantation", Ophthalmology, 110, pp.1799~1806 (2003)
  26. Dawczynski J, "Anterior segment optical coherence tomography for evaluation of changes in anterior chamber angle and depth after intraocular lens implantation in eyes with glaucoma", Eur J Ophthalmol, 17, pp.363~367 (2007)
  27. 장동호, "전안부 빛간섭단층촬영을 이용한 백내장 수술 후 앞방깊이와 앞방각의 변화 측정", 대한안과학회지, 49(9), pp.1443~1452 (2008), 대한안과학회
  28. Leung CK, "Visualization of anterior chamber angle dynamics using optical coherence tomography", Ophthalmology, 112, pp.980~984 (2005)
  29. Leung CK, "Dynamic analysis of dark-light changes of the anterior chamber angle with anterior segment OCT", Invest Ophthalmol Vis Sci, 48, pp.4116~4122 (2007)
  30. Nemeth G, "Assessment and reproducibility of anterior chamber depth measurement with anterior segment optical coherence tomography compared with immersion ultrasonography", J Cataract Refract Surg, 33, pp.443~447 (2007)
  31. Jeong-Ho Yi, "Anterior Chamber Measurements by Pentacam and AS-OCT in Eyes With Normal Open Angles", Korean Journal of Ophthalmology, 22(4), pp.242~245 (2008), 대한안과학회
  32. Dubbelman M, "The thickness of the aging human lens obtained from corrected Scheimpflug images", Optom Vis Sci, 78, pp.411~416 (2001)
  33. Williams DL, "Lens morphometry determined by B-mode ultrasonography of the normal and cataractous canine lens", Vet Ophthalmol, 7, pp.91~95 (2004)
  34. Kim JS, "Periodic biometry in three types of posteriorly implanted IOLs:PMMA,silicone,and acrylic soft,by EAS-1000 Scheimpflug photography", J Korean Ophthalmol Soc, 41, pp.2205~2210 (2000)
  35. Hosny M, "Relationship between anterior chamber depth,refractive state,corneal diameter,and axial length", J Refract Surg, 16, pp.336~340 (2000)
  36. Pavlin CJ, "Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes", Am J Ophthalmol, 113, pp.381~389 (1992)

관련 논문AI추천

이 간행물의 다른 논문 (14건)