초록
Purpose: To compare the efficacy of the transconjunctival releasable suture technique for pars plana vitrectomy using 23-gauge (23G) instruments versus the conventional 20-gauge (20G) technique. Methods: A retrospective and interventional case series was consecutively performed for 199 eyes of the 192 patients that were a part of this study. Clinical data were reviewed retrospectively regarding the operation time, preoperative and postoperative intraocular pressure, visual acuity and astigmatism for 54 consecutive patients who received a 23G releasable suture vitrectomy and for 98 consecutive patients who received a 20G conventional vitrectomy during the period between April 2007 and September 2010. Results: Mean operation time based on the operation record was 88.5 ± 20.1 minutes in the 23G releasable suture vitrectomy group and 102.1 ± 23.1 minutes in the 20G conventional vitrectomy group, respectively (p = 0.01). The last best-corrected visual acuity (BCVA) was significantly better than the preoperative BCVA in both patient groups (p = 0.01, p = 0.01). The 23G releasable suture group showed less surgically induced astigmatism than the 20G conventional vitrectomy group. Vitreous bleeding was observed to be in 6 eyes (5.9%) in the 23G group, and in 8 eyes (8.2%) in the 20G group. In addition, ocular hypertension was noted to be in 3 eyes (3.0%) in the 23G group, and 6 eyes (6.1%) in the 20G group. No serious complications such as postoperative hypotony or endophthalmitis were observed in either group. Conclusions: The 23G releasable suture technique is as effective as the 20G conventional technique and offers several advantages.
Abstract
Purpose: To compare the efficacy of the transconjunctival releasable suture technique for pars plana vitrectomy using 23-gauge (23G) instruments versus the conventional 20-gauge (20G) technique. Methods: A retrospective and interventional case series was consecutively performed for 199 eyes of the 192 patients that were a part of this study. Clinical data were reviewed retrospectively regarding the operation time, preoperative and postoperative intraocular pressure, visual acuity and astigmatism for 54 consecutive patients who received a 23G releasable suture vitrectomy and for 98 consecutive patients who received a 20G conventional vitrectomy during the period between April 2007 and September 2010. Results: Mean operation time based on the operation record was 88.5 ± 20.1 minutes in the 23G releasable suture vitrectomy group and 102.1 ± 23.1 minutes in the 20G conventional vitrectomy group, respectively (p = 0.01). The last best-corrected visual acuity (BCVA) was significantly better than the preoperative BCVA in both patient groups (p = 0.01, p = 0.01). The 23G releasable suture group showed less surgically induced astigmatism than the 20G conventional vitrectomy group. Vitreous bleeding was observed to be in 6 eyes (5.9%) in the 23G group, and in 8 eyes (8.2%) in the 20G group. In addition, ocular hypertension was noted to be in 3 eyes (3.0%) in the 23G group, and 6 eyes (6.1%) in the 20G group. No serious complications such as postoperative hypotony or endophthalmitis were observed in either group. Conclusions: The 23G releasable suture technique is as effective as the 20G conventional technique and offers several advantages.
참고문헌 (24)
- Eckardt C., "Transconjunctival sutureless 23-gauge vitrectomy", Retina, 25, pp.208~211 (2005)
- Jackson T., "Modified sutureless sclerotomies in pars plana vitrectomy", Am J Ophthalmol, 129, pp.116~117 (2000)
- Assi AC, "Reversed self-sealing pars plana sclerotomies", Retina, 20, pp.689~692 (2000)
- Morlet N, "Astigmatism and the analysis of its surgical correction", Br J Ophthalmol, 85, pp.1127~1138 (2001)
- Chen JC., "Sutureless pars plana vitrectomy through self-sealing sclerotomies", Arch Ophthalmol, 114, pp.1273~1275 (1996)
- Milibak T, "Complications of sutureless pars plana vitrectomy through self-sealing sclerotomies", Arch Ophthalmol, 116, pp.119~ (1998)
- Kwok AK, "Modified sutureless sclerotomies in pars plana vitrectomy", Am J Ophthalmol, 127, pp.731~733 (1999)
- Wimpissinger B, "23-Gauge versus 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial", Br J Ophthalmol, 92, pp.1483~1487 (2008)
- Kadonosono K, "Comparison of visual function after epiretinal membrane removal by 20-gauge and 25-gauge vitrectomy", Am J Ophthalmol, 142, pp.513~515 (2006)
- Weinberger D, "Corneal topographic changes after retinal and vitreous surgery", Ophthalmology, 106, pp.1521~1524 (1999)
- Azar-Arevalo O, "Corneal topography changes after vitreoretinal surgery", Ophthalmic Surg Lasers, 32, pp.168~172 (2001)
- Slusher MM, "Clinically significant corneal astigmatism and pars plana vitrectomy", Ophthalmic Surg Lasers, 33, pp.5~8 (2002)
- Bergmann MT, "The effect of scleral cautery on corneal astigmatism in cadaver eyes", Ophthalmic Surg, 19, pp.259~262 (1988)
- Wirbelauer C, "Corneal shape changes after pars plana vitrectomy", Graefes Arch Clin Exp Ophthalmol, 236, pp.822~828 (1998)
- Gupta OP, "The competency of pars plana vitrectomy incisions: a comparative histologic and spectrophotometric analysis", Am J Ophthalmol, 147, pp.243~250 (2009)
- Ooto S, "Suprachoroidal fluid as a complication of 23-gauge vitreous surgery", Br J Ophthalmol, 92, pp.1433~1434 (2008)
- Sabti K, "Ultrasound biomicroscopy of sclerotomy sites: the effect of vitreous shaving around sclerotomy sites during pars plana vitrectomy", Retina, 21, pp.464~468 (2001)
- Taban M, "Evaluation of wound closure in oblique 23-gauge sutureless sclerotomies with visante optical coherence tomography", Am J Ophthalmol, 147, pp.101~107 (2009)
- Chen D, "Sutureless vitrectomy incision architecture in the immediate postoperative period evaluated in vivo using optical coherence tomography", Ophthalmology, 117, pp.2003~2009 (2010)
- Song Y, "Adjunctive use of a novel releasable suture technique in transconjunctival vitrectomy", Retina, 31, pp.243~249 (2011)
- Parolini B, "Postoperative complications and intraocular pressure in 943 consecutive cases of 23-gauge transconjunctival pars plana vitrectomy with 1-year follow-up", Retina, 30, pp.107~111 (2010)
- Lee BR, "Releasable suture technique for the prevention of incompetent wound closure in transconjunctival vitrectomy", Retina, 28, pp.1163~1165 (2008)
- Woo SJ, "Risk factors associated with sclerotomy leakage and postoperative hypotony after 23-gauge transconjunctival sutureless vitrectomy", Retina, 29, pp.456~463 (2009)
- Gupta OP, "Postoperative complications associated with 25-gauge pars plana vitrectomy", Ophthalmic Surg Lasers Imaging, 38, pp.270~275 (2007)