Clinical Performance Comparison of Ultrahigh-speed Dual Pneumatic Vitrectomy Probes: Is Faster and Smaller Better?

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류안과학

초록

Purpose: Various vitrectomy probes are currently being used commercially, and there are ongoing efforts toward developing probes with higher cutting rates and smaller gauges. This study aimed to compare the efficiency and safety of various commercially available small gauge ultrahigh-speed dual pneumatic vitrectomy probes. Methods: We retrospectively analyzed the medical records of patients and recorded intraoperative videos while they underwent microincision three-port vitrectomy surgery for idiopathic epiretinal membrane at Soonchunhyang University Seoul Hospital. The patients were categorized into four groups based on the vitrectomy probe used during surgery: 23-7500 (UltraVit 23-gauge 7,500 cuts per minute [CPM]), 23-7500 (UltraVit 25-gauge 7,500 CPM), 25-10K (Advanced UltraVit 25-gauge 10,000 CPM), and 27-10K (Advanced UltraVit 27-gauge 10,000 CPM). Results: In total, 82 eyes from 82 patients were included in this work, with 16, 11, 26, and 29 eyes in groups 23-7500, 25- 7500, 25-10K, and 27-10K, respectively. The corresponding vitrectomy times were 295.56 ± 53.55, 293.09 ± 50.28, 299.92 ± 59.42, and 349.38 ± 67.23 seconds, respectively. There was a significant difference in the vitrectomy time between the groups (p = 0.004). The mean number of sutures was 3, 3, 2.96, and 0.83, respectively. In the 23-7500 group, there was one case of iatrogenic retinal break, while in the 27-10K group, there was one case of postoperative hypotony. Conclusions: Although advancements have been made in the 27-gauge vitrectomy probe, it still takes more vitrectomy time than it does when using the 23- and 25-gauge probes. However, the delay was within an average of 1 minute, and considering the significantly reduced need for sutures, there is a substantial benefit in terms of postoperative discomfort. Therefore, when choosing a probe for epiretinal membrane surgery among the four options, it is reasonable to select the 27-gauge probe according to the surgeon’s preference.

Abstract

Purpose: Various vitrectomy probes are currently being used commercially, and there are ongoing efforts toward developing probes with higher cutting rates and smaller gauges. This study aimed to compare the efficiency and safety of various commercially available small gauge ultrahigh-speed dual pneumatic vitrectomy probes. Methods: We retrospectively analyzed the medical records of patients and recorded intraoperative videos while they underwent microincision three-port vitrectomy surgery for idiopathic epiretinal membrane at Soonchunhyang University Seoul Hospital. The patients were categorized into four groups based on the vitrectomy probe used during surgery: 23-7500 (UltraVit 23-gauge 7,500 cuts per minute [CPM]), 23-7500 (UltraVit 25-gauge 7,500 CPM), 25-10K (Advanced UltraVit 25-gauge 10,000 CPM), and 27-10K (Advanced UltraVit 27-gauge 10,000 CPM). Results: In total, 82 eyes from 82 patients were included in this work, with 16, 11, 26, and 29 eyes in groups 23-7500, 25- 7500, 25-10K, and 27-10K, respectively. The corresponding vitrectomy times were 295.56 ± 53.55, 293.09 ± 50.28, 299.92 ± 59.42, and 349.38 ± 67.23 seconds, respectively. There was a significant difference in the vitrectomy time between the groups (p = 0.004). The mean number of sutures was 3, 3, 2.96, and 0.83, respectively. In the 23-7500 group, there was one case of iatrogenic retinal break, while in the 27-10K group, there was one case of postoperative hypotony. Conclusions: Although advancements have been made in the 27-gauge vitrectomy probe, it still takes more vitrectomy time than it does when using the 23- and 25-gauge probes. However, the delay was within an average of 1 minute, and considering the significantly reduced need for sutures, there is a substantial benefit in terms of postoperative discomfort. Therefore, when choosing a probe for epiretinal membrane surgery among the four options, it is reasonable to select the 27-gauge probe according to the surgeon’s preference.

참고문헌 (24)

  1. Fujii GY, "A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery", Ophthalmology, 109, pp.1807~1813 (2002)
  2. Recchia FM, "Small-gauge pars plana v itrectomy : a report by t he A merican Academy of Ophthalmology", Ophthalmology, 117, pp.1851~1857 (2010)
  3. Thompson JT, "Advantages and limitations of small gauge vitrectomy", Surv Ophthalmol, 56, pp.162~172 (2011)
  4. Diniz B, "Fluidics in a dual pneumatic ultra high-speed vitreous cutter system", Ophthalmologica, 229, pp.15~20 (2013)
  5. Scott MN, "The evolution of pars plana vitrectomy to 27-G microincision vitrectomy surgery", Int Ophthalmol Clin, 56, pp.97~111 (2016)
  6. Mohamed S, "Review of small gauge vitrectomy : progress and innovations", J Ophthalmol, 2017, pp.6285869~ (2017)
  7. Sato T, "Analyses of cutting and aspirating properties of vitreous cutters with highspeed camera", Retina, 28, pp.749~754 (2008)
  8. Matsuoka N, "Performance analysis of millennium vitreous enhancer™ system", Ophthalmic Surg Lasers Imaging, 42, pp.162~167 (2011)
  9. Inoue M, "Flow dynamics of beveled-tip and flat-tip vitreous cutters", Retina, 41, pp.445~453 (2021)
  10. Ribeiro R M, "Performance analysis of ultrahigh-speed vitreous cutter system", Retina, 33, pp.928~932 (2013)
  11. Rossi T, "Fluid dynamics of vitrectomy probes", Retina, 34, pp.558~567 (2014)
  12. Saleh OA, "Comparison of characteristics and clinical outcomes in 27-gauge versus 23-gauge vitrectomy surgery", Clin Ophthalmol, 14, pp.1553~1558 (2020)
  13. Downey JM, "Essential medical physiology", pp.157~174 (2003), Elsevier
  14. Silva AF, "Rheological behaviour of vitreous humour", Rheol Acta, 56, pp.377~386 (2017)
  15. Abulon D, "Fluidics behavior during vitrectomy", Retina Today, pp.74~80 (2010)
  16. Dugel PU, "Comparison of attraction capabilities associated with high-speed, dual-pneumatic vitrectomy probes", Retina, 35, pp.915~920 (2015)
  17. Dugel PU, "Tissue attraction associated with 20-gauge, 23-gauge, and enhanced 25-gauge dual-pneumatic vitrectomy probes", Retina, 32, pp.1761~1766 (2012)
  18. Patel S, "High-speed beveled tip versus standard tip vitrectomy probe : a prospective randomized clinical trial", J Ophthalmic Vis Res, 18, pp.405~409 (2023)
  19. Mariotti C, "Standard cut rate 25-gauge vitrectomy versus ultrahigh-speed 25-gauge system in core vitrectomy : a randomized clinical trial", Retina, 36, pp.1271~1274 (2016)
  20. Azhdam AM, "In vivo measurement of the human vitreous chamber volume using computed tomography imaging of 100 eyes", Transl Vis Sci Technol, 9, pp.2~ (2020)
  21. de Santana JM, "Use of axial length to estimate the vitreous chamber volume in pseudophakic", Graefes Arch Clin Exp Ophthalmol, 259, pp.1471~1475 (2021)
  22. Tanaka H, "Measurement of volume of vitreous space during vitrectomy", Invest Ophthalmol Vis Sci, 50, pp.3169~ (2009)
  23. Woo SJ, "Risk factors associated with sclerotomy leakage and postoperative hypotony after 23-gauge transconjunctival sutureless vitrectomy", Retina, 29, pp.456~463 (2009)
  24. Acar N, "Early postoperative hypotony after 25-gauge sutureless vitrectomy with straight incisions", Retina, 28, pp.545~552 (2008)

관련 논문AI추천

이 간행물의 다른 논문 (13건)