Purpose: To describe cases of exposed hydroxyapatite (HA) implants wrapped with the synthetic dura substituteNeuro-Patch treated via simple Neuro-Patch removal. Methods: The medical records of seven patients who experienced exposure of their HA implant were reviewed. All patients had been enucleated and implanted with HA wrapped with Neuro-Patch. For treatment, Neuro-Patch was removed to the greatest extent possible. After applying local anesthesia with lidocaine, bluntdissection was performed to separate the conjunctiva and Neuro-Patch via the site of exposure. Pressure wasapplied to the remaining Neuro-Patch with forceps and removed with scissors. Results: Neuro-Patch was visible at the area of exposure in all patients. No surgery beyond initial Neuro-Patchremoval was necessary in six of the seven patients. In five cases, the exposed area began to heal rapidly afterNeuro-patch removal without primary closure of the defect. In one case, the Neuro-Patch material and allnecrotic tissue was removed aggressively due to inflammation around the orbital implant. Lastly, an infectionwas noted in one case, prompting complete removal of the Neuro-Patch–wrapped HA implant. Conclusions: Wrapping material may hinder implant vascularization. Exposure of HA in wrapped implants canbe successfully treated by a simple removal procedure if detected and managed early.

Abstract

Purpose: To describe cases of exposed hydroxyapatite (HA) implants wrapped with the synthetic dura substituteNeuro-Patch treated via simple Neuro-Patch removal. Methods: The medical records of seven patients who experienced exposure of their HA implant were reviewed. All patients had been enucleated and implanted with HA wrapped with Neuro-Patch. For treatment, Neuro-Patch was removed to the greatest extent possible. After applying local anesthesia with lidocaine, bluntdissection was performed to separate the conjunctiva and Neuro-Patch via the site of exposure. Pressure wasapplied to the remaining Neuro-Patch with forceps and removed with scissors. Results: Neuro-Patch was visible at the area of exposure in all patients. No surgery beyond initial Neuro-Patchremoval was necessary in six of the seven patients. In five cases, the exposed area began to heal rapidly afterNeuro-patch removal without primary closure of the defect. In one case, the Neuro-Patch material and allnecrotic tissue was removed aggressively due to inflammation around the orbital implant. Lastly, an infectionwas noted in one case, prompting complete removal of the Neuro-Patch–wrapped HA implant. Conclusions: Wrapping material may hinder implant vascularization. Exposure of HA in wrapped implants canbe successfully treated by a simple removal procedure if detected and managed early.

참고문헌 (19)

  1. Dutton JJ, "Coralline hydroxyapatite as an ocular implant", Ophthalmology, 98, pp.370~377 (1991)
  2. Perry AC, "Integrated orbital implants", Adv Ophthalmic Plast Reconstr Surg, 8, pp.75~81 (1990)
  3. Jordan DR, "Wrapping hydroxyapatite implants", Ophthalmic Surg Lasers, 30, pp.403~407 (1999)
  4. Lee V, "Exposure of primary orbital implants in postenucleation retinoblastoma patients", Ophthalmology, 107, pp.940~945 (2000)
  5. Shields CL, "Hydroxyapatite orbital implant after enucleation. Experience with initial 100 consecutive cases", Arch Ophthalmol, 110, pp.333~338 (1992)
  6. Shields JA, "Enucleation technique for children with retinoblastoma", J Pediatr Ophthalmol Strabismus, 29, pp.213~215 (1992)
  7. Yamada S, "Creutzfeldt-Jakob disease transmitted by a cadaveric dura mater graft", Neurosurgery, 34, pp.740~743 (1994)
  8. Mehta JS, "The sclera, the prion, and the ophthalmologist", Br J Ophthalmol, 86, pp.587~592 (2002)
  9. Raul JS, "Use of polyester urethane (Neuro-Patch) as a dural substitute. Prospective study of 70 cases", Neurochirurgie, 49(2-3 Pt 1), pp.83~89 (2003)
  10. Seiff SR, "Polymerase chain reaction identification of human immunodeficiency virus-1 in preserved human sclera", Am J Ophthalmol, 118, pp.528~530 (1994)
  11. Simonds RJ, "Transmission of human immunodeficiency virus type 1 from a seronegative organ and tissue donor", N Engl J Med, 326, pp.726~732 (1992)
  12. Jordan DR, "Vicryl-mesh wrap for the implantation of hydroxyapatite orbital implants : an animal model", Can J Ophthalmol, 30, pp.241~246 (1995)
  13. Jordan DR, "The use of Vicryl mesh(polyglactin 910)for implantation of hydroxyapatite orbital implants", Ophthalmic Plast Reconstr Surg, 11, pp.95~99 (1995)
  14. Oestreicher JH, "Complications of hydroxyapatite orbital implants. A review of 100 consecutive cases and a comparison of Dexon mesh (polyglycolic acid)with scleral wrapping", Ophthalmology, 104, pp.324~329 (1997)
  15. Gudmundsson G, "Complications to the use of vicryl-collagen dural substitute", Acta Neurochir(Wien), 132, pp.145~147 (1995)
  16. Malliti M, "Comparison of deep wound infection rates using a synthetic dural substitute(neuro-patch)or pericranium graft for dural closure : a clinical review of 1 year", Neurosurgery, 54, pp.599~603 (2004)
  17. El Majdoub F, "Transmigration of fibrino-purulent inflammation and malignant cells into an artificial dura substitute (Neuro-Patch): report of two cases", Acta Neurochir(Wien), 151, pp.833~835 (2009)
  18. Heimann H, "Exposure of orbital implants wrapped with polyester-urethane after enucleation for advanced retinoblastoma", Ophthalmic Plast Reconstr Surg, 21, pp.123~128 (2005)
  19. Kaltreider SA, "Prevention and management of complications associated with the hydroxyapatite implant", Ophthalmic Plast Reconstr Surg, 12, pp.18~31 (1996)

관련 논문AI추천

이 간행물의 다른 논문 (14건)