본문 바로가기
KERD
논문KCI 등재

A Comparative Evaluation of Absorbable and Nonabsorbable Sutures for Open Repair of Achilles Tendon Rupture - A Pilot Study

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류해부학

초록

This pilot study was performed to compare the functional and clinical results including complications after surgery in the open repair of Achilles tendon rupture with regard to the type of suture material. A consecutive series of twenty patients with acute Achilles tendon rupture who underwent open repair were enrolled in this pilot study. The patients were divided equally into 2 groups according to suture type. In the nonabsorbable suture group, No. 2 braided nonabsorbable polyethylene terephthalate sutures were used, and in the absorbable suture group, braided absorbable polyglactin sutures were used. The Korean version of the Foot and Ankle Outcome Score (FAOS) and complications were assessed to evaluate functional and clinical result. Mean total Foot and Ankle Outcome Score (FAOS) was 89.8 (range, 71.1~100) in the nonabsorbable suture group and 82.7 (range, 61.9~92.5) in the absorbable suture group (p=0.22). All patients returned to their previous life activity. The absorbable suture group had fewer postoperative complications (10%) than the nonabsorbable suture group (20%), but there was no significant difference between two groups (p=0.45). This pilot study showed that use of an absorbable suture for Achilles tendon repair had functional and clinical results comparable to those of the nonabsorbable suture. However, a use of an absorbable suture was associated with a lower incidence of complications than the use of nonabsorbable suture. Therefore, these results have to be confirmed in a randomized controlled cohort trial with larger population.

Abstract

This pilot study was performed to compare the functional and clinical results including complications after surgery in the open repair of Achilles tendon rupture with regard to the type of suture material. A consecutive series of twenty patients with acute Achilles tendon rupture who underwent open repair were enrolled in this pilot study. The patients were divided equally into 2 groups according to suture type. In the nonabsorbable suture group, No. 2 braided nonabsorbable polyethylene terephthalate sutures were used, and in the absorbable suture group, braided absorbable polyglactin sutures were used. The Korean version of the Foot and Ankle Outcome Score (FAOS) and complications were assessed to evaluate functional and clinical result. Mean total Foot and Ankle Outcome Score (FAOS) was 89.8 (range, 71.1~100) in the nonabsorbable suture group and 82.7 (range, 61.9~92.5) in the absorbable suture group (p=0.22). All patients returned to their previous life activity. The absorbable suture group had fewer postoperative complications (10%) than the nonabsorbable suture group (20%), but there was no significant difference between two groups (p=0.45). This pilot study showed that use of an absorbable suture for Achilles tendon repair had functional and clinical results comparable to those of the nonabsorbable suture. However, a use of an absorbable suture was associated with a lower incidence of complications than the use of nonabsorbable suture. Therefore, these results have to be confirmed in a randomized controlled cohort trial with larger population.

참고문헌 (19)

  1. Leppilahti J, "Incidence of Achilles tendon rupture", Acta Orthop Scand, 67, pp.277~279 (1996)
  2. Dalton GP, "Complications of achilles and posterior tibial tendon surgeries", Clin Orthop Relat Res, 391, pp.133~139 (2001)
  3. Pajala A, "Rerupture and deep infection following treatment of total Achilles tendon rupture", J Bone Joint Surg Am, 84(A), pp.2016~2021 (2002)
  4. Esenyel CZ, "Evaluation of soft tissue reactions to three nonabsorbable suture materials in a rabbit model", Acta Orthop Traumatol Turc, 43, pp.366~372 (2009)
  5. Carr BJ, "Biologic response to orthopedic sutures: a histologic study in a rabbit model", Orthopedics, 32, pp.828~ (2009)
  6. Wada A, "Effect of absorbable polydioxanone flexor tendon repair and restricted active mobilization in a canine model", J Hand Surg Am, 26, pp.398~406 (2001)
  7. Yildirim Y, "Tendon holding capacities of the suture materials used in repairing Achilles tendon rupture", Acta Orthop Traumatol Turc, 40, pp.164~168 (2006)
  8. Lee KM, "Transcultural adaptation and testing psychometric properties of the Korean version of the Foot and Ankle Outcome Score (FAOS)", Clin Rheumatol, 32, pp.1443~1450 (2013)
  9. Roos EM, "Validation of the foot and ankle outcome score for ankle ligament reconstruction", Foot Ankle Int, 22, pp.788~794 (2001)
  10. Trail IA, "An evaluation of suture materials used in tendon surgery", J Hand Surg Br, 14, pp.422~427 (1989)
  11. Bourne RB, "In-vivo comparison of four absorbable sutures:Vicryl, Dexon Plus, Maxon and PDS", Can J Surg, 31, pp.43~45 (1988)
  12. O’Broin ES, "Absorbable sutures in tendon repair. A comparison of PDS with prolene in rabbit tendon repair", J Hand Surg Br, 20, pp.505~508 (1995)
  13. Hyung Joo Kang, "Flexor Tenorrhaphy using Absorbable Suture Materials", Archives of Plastic Surgery, 39(4), pp.397~403 (2012), 대한성형외과학회[DOI]
  14. Bruggeman NB, "Wound complications after open Achilles tendon repair: an analysis of risk factors", Clin Orthop Relat Res, 427, pp.63~66 (2004)
  15. Ollivere BJ, "Foreign body granulomatous reaction associated with polyethelene ‘Fiberwire((R))’ suture material used in Achilles tendon repair", Foot Ankle Surg, 20, pp.e27~e29 (2014)
  16. Kara A, "Granuloma formation secondary to Achilles tendon repair with nonabsorbable suture", Int J Surg Case Rep, 5, pp.720~722 (2014)
  17. Najibi S, "Material properties of common suture materials in orthopaedic surgery", Iowa Orthop J, 30, pp.84~88 (2010)
  18. 김도연, "급성 아킬레스건 파열의 수술적 치료: 경피적 봉합술과 관혈적 봉합술의 비교", 대한족부족관절학회지, 15(2), pp.79~85 (2011), 대한족부족관절학회
  19. Ahluwalia R, "Chronic sinus formation using non absorbable braided suture following open repair of Achilles tendon", Foot Ankle Surg, 19, pp.e7~e9 (2013)

관련 논문AI추천