Experimental and CFD Study on the Exhaust Efficiency of a Smoke Control Fan in Blind Entry Development Sites
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
The ventilation system plays a crucial role in underground mine safety. The main objective of the ventilation system is to supply sufficient air to dilute the contaminated air at working places and consequently provide tenable environment during the normal operation, while it also should be capable of controlling the fire propagation and facilitate rescue conditions in case of fire in mines. In this study, a smoke control fan was developed for the auxiliary ventilation as well as the fire smoke exhaust. It works as a free-standing auxiliary fan without tubing to dilute or exhaust the contaminated air from the working places. At the same time, it can be employed to extract the fire smoke. This paper aims to examine the smoke control efficiency of the fan when combined with the current ventilation system in mines. A series of the site experiments and numerical simulations were made to evaluate the fan performance in blind entry development sites. The tracer gas method with SF6 was applied to investigate the contaminant behavior at the study sites. The results of the site study at a large-opening limestone mine were compared with the CFD analysis results with respect to the airflow pattern and the gas concentration. This study shows that in blind development entry, the most polluted and risky place, the smoke fan can exhaust toxic gases or fire smoke effectively if it is properly combined with an additional common auxiliary fan. The venturi effect for smoke exhaust from the blind entry was also observed by the numerical analysis. The overall smoke control efficiency was found to be dependent on the fan location and operating method.
Abstract
The ventilation system plays a crucial role in underground mine safety. The main objective of the ventilation system is to supply sufficient air to dilute the contaminated air at working places and consequently provide tenable environment during the normal operation, while it also should be capable of controlling the fire propagation and facilitate rescue conditions in case of fire in mines. In this study, a smoke control fan was developed for the auxiliary ventilation as well as the fire smoke exhaust. It works as a free-standing auxiliary fan without tubing to dilute or exhaust the contaminated air from the working places. At the same time, it can be employed to extract the fire smoke. This paper aims to examine the smoke control efficiency of the fan when combined with the current ventilation system in mines. A series of the site experiments and numerical simulations were made to evaluate the fan performance in blind entry development sites. The tracer gas method with SF6 was applied to investigate the contaminant behavior at the study sites. The results of the site study at a large-opening limestone mine were compared with the CFD analysis results with respect to the airflow pattern and the gas concentration. This study shows that in blind development entry, the most polluted and risky place, the smoke fan can exhaust toxic gases or fire smoke effectively if it is properly combined with an additional common auxiliary fan. The venturi effect for smoke exhaust from the blind entry was also observed by the numerical analysis. The overall smoke control efficiency was found to be dependent on the fan location and operating method.
참고문헌 (20)
- ANSYS, Inc., "FLUENT User's Guide, Version 17.0", ANSYS, Inc, ~ (2017)
- Bickel, KL., "Analysis of diesel-powered mine equipment", Proceedings of the Bureau of Mines Technology Transfer Seminar: Diesels in Underground Mines. Information Circular 9141 (1987), US Bureau of Mines
- Chekan, G. J., "Impact of fan type for reducing respirable dust at an underground limestone crushing facility", 11th US, North American Mine Ventilation Symposium, pp.2006[DOI]
- Analysis of mine fires for all US metal, "non-metal mining categories, 1990-2001", De Rosa M.I., 2004
- CFD analysis of mine fire smoke spread and reverse flow conditions, "Edwards J.C.", NIOSH, ~ (1999)
- Experimental and modelling investigation of the effect of ventilation on smoke rollback in a mine entry, "Edwards J.C.", NIOSH, ~ (2006)
- Foster - Miller's development of dry coal feed systems, "FOSTER - MILLER associates, Inc.", Waltham, ~ (1980)
- Jet fan ventilation in very deep cuts: a preliminary analysis, "Goodman G.V.", US Department of the Interior, US Bureau of Mines, ~ (1992)
- GRAMKO annual report 2005, , SVEMIN, ~ (2005)
- Grau III, R. H., "Practical techniques to improve the air quality in underground stone mines", Ninth North American, 2002, 123~129
- Grau III, R.H., "Maximizing the ventilation of large-opening mines", Proceedings of the 11th US, 2006, 53~59
- Graul III, R. H., "Using mine planning and other techniques to improve ventilation in large-opening mines", Mining Engineering, 61(2), pp.46~ (2009)
- 이창우, "Development of a Low Pressure Auxiliary Fan for Local Large-opening Limestone Mines", 터널과 지하공간, 25(6), pp.543~555 (2015), 한국암반공학회
- Changwoo Lee, "A study on the fire propagation characteristics in large-opening multi-level limestone mines in Korea", Geosystem Engineering, 19(6), pp.317~336 (2016), 한국자원공학회
- 박동준, "대단면 석회석 광산 갱도 내 국부선풍기 승압력 및 통기효과 비교 연구", 터널과 지하공간, 27(1), pp.1~11 (2017), 한국암반공학회[DOI]
- Development of a fire and explosion risk assessment methodology for underground mines, "Thyer A.M.", Health and Safety Laboratory, ~ (2002)
- Yuan L., "The effects of ventilation and preburn time on water mist extinguishing of diesel fuel pool fires", Journal of Fire Sciences, 22, pp.379~404 (2004)
- Experimental study of flame spread on conveyor belts in a small-scale tunnel, "Yuan L.", NIOSH, ~ (2007)
- Ignition of hydraulic fluid sprays by open flames and hot surfaces, "Yuan L.", NIOSH, ~ (2006)
- Zhou F., "Backdraft in descensionally ventilated mine fire", Journal of Fire Sciences, 23, pp.261~271 (2005)
