In local underground mines heavily depending on the natural ventilation, ducted fan auxiliary ventilation system is strongly recommended instead of the total mine ventilation system requiring large capital and operating costs. Optimizing the installation of ducted fans in series in long large-opening mines is required to assure the economy and efficiency of the ventilation system. The two most critical design parameters for optimization are the wall separation distance and gap length between adjoining ducts. This study aims at deriving the optimal values for those two parameters concerning the economic and environmental aspects through the extensive CFD analysis, which minimizes pressure loss, leakage and entrainment of the contaminated air in the gap space. The ranges of the wall separation distance and gap length for study are selected by taking into consideration the existing recommendations and guidelines. The ultimate goal is to optimize the auxiliary ventilation system using ducted fans in series to provide a reliable and efficient solution to maintain clean and safe workplace environment in local long underground mines.
Abstract
In local underground mines heavily depending on the natural ventilation, ducted fan auxiliary ventilation system is strongly recommended instead of the total mine ventilation system requiring large capital and operating costs. Optimizing the installation of ducted fans in series in long large-opening mines is required to assure the economy and efficiency of the ventilation system. The two most critical design parameters for optimization are the wall separation distance and gap length between adjoining ducts. This study aims at deriving the optimal values for those two parameters concerning the economic and environmental aspects through the extensive CFD analysis, which minimizes pressure loss, leakage and entrainment of the contaminated air in the gap space. The ranges of the wall separation distance and gap length for study are selected by taking into consideration the existing recommendations and guidelines. The ultimate goal is to optimize the auxiliary ventilation system using ducted fans in series to provide a reliable and efficient solution to maintain clean and safe workplace environment in local long underground mines.
참고문헌 (14)
- De Souza, E., "Mine Ventilation", pp.341~349 (2004), Taylor & Francis Routledge
- Khanna, R.K., "Ventilation of long tunnels", World tunnel congress 2008 – Underground facilities for better environmental and safety – India, pp.1898~1910 (2008)
- 조형제, "초장대 해저터널의 공사중 환기 특성에 관한 기초연구 - 현황 및 개선필요사항 중심", 한국터널지하공간학회 논문집, 17(2), pp.153~166 (2015), 사단법인 한국터널지하공간학회
- MOLIT (Korean Ministry of Land, Infrastructure and Transportation), "The sixth section, Tunnel, in The guideline for the vehicle tunnel design", ~ (2010)
- ANSYS, Inc., "FLUENT User’s Guide. Version 15.0", ANSYS, Inc, ~ (2015)
- Anisdahl, L. M., "Study on the performance of ventiflex ducting and couplings", Proceedings of 12th US, 2008, 609~613
- Vutukuri, V. S., "Uncontrolled recirculation in auxiliary ventilation with fans in series along the duct", Mining Science and Technology, 5(3), pp.287~297 (1987)
- Gillies A. D. S., "A Comparison of Air Leakage Prediction Techniques for Auxiliary Ventilation Ducting Systems", Proceedings of the 8th US Mine Ventilation Symposium, pp.681~690 (1999), University of Missouri-Rolla Press
- Schweizerishcher Ingenieur – und Architekten – Verein (SIA), "SIA 196 Bauluftung im Unteragabau", SIA, ~ (1998)
- Using sulfur hexafluoride as a gaseous tracer to study ventilation systems in mines, "Thimons, R. J. B.", Bureau of Mines, ~, pp.No.BM-RI-7916 (1974)
- Hartman, H. L., "Mine ventilation and air conditioning", pp.730~ (2012), John Wiley & Sons
- Rivers Carbon Technologies, "Australian Mine Safety Technology Center", ~ (2010)
- Brake, D. J., "Design and operational aspects in the use of booster, circuit and auxiliary fan systems", Proceedings of the 11th US, 2006, 543~553
- "ANSI", UL 181, Standard for Safety Factory-Made Air Ducts and Air Connectors, 2013