In this study, sloshing effects on the heat transfer coefficient of the vertical walls in a membrane type LNG cargo containment system (CCS) were analyzed. To develop correlations of the heat transfer coefficient incorporating sloshing effects, experiments were conducted to measure the heat transfer coefficient of an oscillating vertical plate. Based on experiments, two different correlations were developed which are each applicable to vertical and horizontal oscillations. Using the developed correlations, the heat flow rate penetrated into the vertical walls in KC-1 CCS was investigated under sloshing conditions. The results showed that the penetrated heat flow rate increases with the sloshing speed, which is defined as the product of the sloshing amplitude and the frequency. The maximum increase ratio of the heat flow rate was found to be about 7.5% at the sloshing speed of 10m/s. Also, it was found that the penetrated heat flow rate more increases when the CCS oscillates in the perpendicular direction to the vertical walls, than the parallel direction to the vertical walls. This study suggests that the increase in wall heat transfer coefficients has to be considered when evaluating the boil-off rate of CCSs that are shaking due to sloshing.

Abstract

In this study, sloshing effects on the heat transfer coefficient of the vertical walls in a membrane type LNG cargo containment system (CCS) were analyzed. To develop correlations of the heat transfer coefficient incorporating sloshing effects, experiments were conducted to measure the heat transfer coefficient of an oscillating vertical plate. Based on experiments, two different correlations were developed which are each applicable to vertical and horizontal oscillations. Using the developed correlations, the heat flow rate penetrated into the vertical walls in KC-1 CCS was investigated under sloshing conditions. The results showed that the penetrated heat flow rate increases with the sloshing speed, which is defined as the product of the sloshing amplitude and the frequency. The maximum increase ratio of the heat flow rate was found to be about 7.5% at the sloshing speed of 10m/s. Also, it was found that the penetrated heat flow rate more increases when the CCS oscillates in the perpendicular direction to the vertical walls, than the parallel direction to the vertical walls. This study suggests that the increase in wall heat transfer coefficients has to be considered when evaluating the boil-off rate of CCSs that are shaking due to sloshing.

참고문헌 (11)

  1. Churchill, S. W., "Correlating equations for laminar and turbulent free convection from a vertical plate", International Journal of Heat and Mass Transfer, 18, pp.1323~ (1975)
  2. Eckert, E. R. G., "Die Berechnung des Warmeuberganges in der laminaren gren-zschicht um stromter korper", VDI-Forschungsheft, 416, pp.1~24 (1942)
  3. Tables of similar solutions to the equations of momentum, heat and mass transfer in laminar boundary layer flow, "Elzy, E.", Engineering Experiment Station, Oregon State University, ~ (1967)
  4. Jeon, G. M., "A numerical study on multiphase-thermal flow considering phase change and sloshing effect in cryogenic tank", Ph.D, pp.2021
  5. Jung, S. M., "Multiphase-thermal analysis for efficient transportation and long-term storage of liquid hydrogen energy", Ph.D, pp.2023
  6. Lee, J. H., "Numerical study of heat flux and BOG in C-type liquefied hydrogen tank under sloshing excitation at the saturated state", Journal of the Computational Structural Engineering Institute of Korea, 35(5), pp.299~308 (2022)
  7. Lee, Y., "Numerical study of producing BOG in a LNG-tank with sloshing effect", The Korean Society of Mechanical Engineers (2020)
  8. Lemlich, R., "Effect of vibration on natural convective heat transfer", Industrial & Engineering Chemistry, 47(6), pp.1175~1180 (1955)
  9. Park, S., "Analysis of droplet breakup and boil off rate due to sloshing phenomena inside liquid fuel tank", The Korean Society of Mechanical Engineers (2023)
  10. Prasad, K. K., "Heat transfer by free convection from a longitudinally vibrating vertical plate", International Journal of Heat and Mass Transfer, 15, pp.1213~1223 (2007)
  11. You, H., "Scale effect analysis of LNG cargo containment system using a thermal resistance network model", Journal of the Society of Naval Architects of Korea, 60(4), pp.222~230 (2023)

관련 논문AI추천

이 간행물의 다른 논문 (11건)