열저항 네트워크 모델을 이용한 LNG 화물창 Scale Effect 분석
Scale Effect Analysis of LNG Cargo Containment System Using a Thermal Resistance Network Model
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
In the present work, the scale effect on the Boil-Off Rate (BOR) was investigated based on an analytical method to systematically evaluate the thermal performance of a Liquefied Natural Gas (LNG) Cargo Containment System (CCS). A two-dimensional thermal resistance network model was developed to accurately estimate the heat ingress into the CCS from the outside. The analysis was performed for the KC-1 LNG membrane tank under the IGC and USCG design conditions. The ballast compartment of both the LNG tank and cofferdam was divided into six sections and a thermal resistance network model was made for each section. To check the validity of the developed model, the analysis results were compared with those from existing literature. It was shown that the BOR values under the IGC and USCG design conditions were agreed well with previous numerical results with a maximum error of 1.03% and 0.60%, respectively. A SDR, the scale factor of the LNG CCS was introduced and the BOR, air temperature of the ballast compartment, and the surface temperature of the inner hull were obtained to examine the influence of the SDR on the thermal performance. Finally, a correlation for the BOR was proposed, which could be expressed as a simple formula inversely proportional to the SDR. The proposed correlation could be utilized for predicting the BOR of a full-scale LNG tank based on the BOR measurement data of lab-scale model tanks.
Abstract
In the present work, the scale effect on the Boil-Off Rate (BOR) was investigated based on an analytical method to systematically evaluate the thermal performance of a Liquefied Natural Gas (LNG) Cargo Containment System (CCS). A two-dimensional thermal resistance network model was developed to accurately estimate the heat ingress into the CCS from the outside. The analysis was performed for the KC-1 LNG membrane tank under the IGC and USCG design conditions. The ballast compartment of both the LNG tank and cofferdam was divided into six sections and a thermal resistance network model was made for each section. To check the validity of the developed model, the analysis results were compared with those from existing literature. It was shown that the BOR values under the IGC and USCG design conditions were agreed well with previous numerical results with a maximum error of 1.03% and 0.60%, respectively. A SDR, the scale factor of the LNG CCS was introduced and the BOR, air temperature of the ballast compartment, and the surface temperature of the inner hull were obtained to examine the influence of the SDR on the thermal performance. Finally, a correlation for the BOR was proposed, which could be expressed as a simple formula inversely proportional to the SDR. The proposed correlation could be utilized for predicting the BOR of a full-scale LNG tank based on the BOR measurement data of lab-scale model tanks.
참고문헌 (16)
- Churchill, S.W., "Correlating equations for laminar and turbulent free convection from a vertical plate", International Journal of Heat and Mass Transfer, 18(11), pp.1323~1329 (1975)
- Colburn, A. P., "A method of correlating forced convection heat-transfer data and a comparison with fluid friction", International Journal of Heat and Mass Transfer, 7(12), pp.1359~1384 (1964)
- World LNG Report 2022, "International Gas Union (IGU)", International Gas Union, ~ (2022)
- The International Code for the Construction and Equipment of Ships Carrying Liquefied Gases in Bulk, "International Maritime Organization(IMO)", International Maritime Organization, ~ (2014)
- 허진욱, "멤브레인형 LNG선 Cargo의 만선항해시 열전달 해석 및 BOG 평가", 대한기계학회논문집 A, 27(3), pp.393~400 (2003), 대한기계학회
- 정현원, "KC-1 Membrane LNG 탱크 단열시스템의 열해석에 관한 연구", 한국해양공학회지, 31(2), pp.91~102 (2017), 한국해양공학회
- Jeong, H., "Calculation of Boil-off Gas(BOG)generation of KC-1 membrane LNG tank with high density rigid polyurethane foam by numerical analysis", Polish Maritime Research, 24(1), pp.100~114 (2017)
- 진교국, "슬로싱 하중을 받는 한국형 LNG선 화물창(KC-1)의 보냉 판넬에 대한 구조 안전성 평가", 한국가스학회지, 17(2), pp.85~89 (2013), 한국가스학회[DOI]
- 이정혜, "급냉각기간에서 멤브레인형 LNGC의 분무냉각 열해석에 관한 연구", 대한기계학회논문집 B, 27(1), pp.117~124 (2003), 대한기계학회
- Martynenko, O.G., "Freeconvective heat transfer : with many photographs of flows and heat exchange" (2005), Springer Science and Business Media
- McAdams, W. H., "Heat transfer", pp.3~ (1954), McGraw-Hill
- Miana, M., "Calculation of boil-off rate of liquefied natural gas in mark III tanks of ship carriers by numerical analysis", Applied Thermal Engineering, 93, pp.279~296 (2016)
- Qu, Y., "A thermal and thermodynamic code for the computation of boil-off gas–industrial applications of LNG carrier", Cryogenics, 99, pp.105~113 (2019)
- Sharqawy, M. H., "Thermophysical properties of seawater: a review of existing correlations and data", Desalination and Water Treatment, 16(1-3), pp.354~380 (2010)
- Song, S. O., "A study on the three-dimensional steady state temperature distributions and BOR calculation program deveolpment for the membrane type LNG carrier", Journal of Korean Society of Marine Engineering, 23(2), pp.140~149 (1999)
- Hazard of LNG spillage in marine transportation, "United States Coast-Guard(USCG)", Department of Transportation, U.S. Coast Guard Hazardous Materials Division, ~, pp.MIPR No. Z-700099-9-92317 (1970)