Previous shape sensors including bend sensors and optic fiber based sensors are widely used in various applications including goniometer and surgical robots. But theses sensors have large nonlinearity, limited in the range of sensing curvature, and sometimes are expensive. This study suggests a new concept of bend sensor using cable-conduit which consists of the outer sheath and the inner wire. The outer sheath is made of helical coil whose length of the central line changes as the sheath bends. This length change of the central line can be measured with the length change of the inner cable. The modeling and the experimental results show that the output signal of the proposed sensor is linearly related with the bend angle of the sheath with root mean square error of 5.3% of 450° sensing range. Also the polynomial calibration of the sensor can decrease the root mean square error to 2.1% of the full sensing range.

Abstract

Previous shape sensors including bend sensors and optic fiber based sensors are widely used in various applications including goniometer and surgical robots. But theses sensors have large nonlinearity, limited in the range of sensing curvature, and sometimes are expensive. This study suggests a new concept of bend sensor using cable-conduit which consists of the outer sheath and the inner wire. The outer sheath is made of helical coil whose length of the central line changes as the sheath bends. This length change of the central line can be measured with the length change of the inner cable. The modeling and the experimental results show that the output signal of the proposed sensor is linearly related with the bend angle of the sheath with root mean square error of 5.3% of 450° sensing range. Also the polynomial calibration of the sensor can decrease the root mean square error to 2.1% of the full sensing range.

참고문헌 (23)

  1. C.T. Gentile, "Angular displacement sensors, US5086785 A", ~ (1992)
  2. J. Jurgens, "Development and evaluation of an inexpensive sensor system for use in measuring relative finger positions", Medical Engineering & Physics, 19(1), pp.1~6 (1997)
  3. L. K. Simone, "Design considerations for a wearable monitor to measure finger posture", Journal of NeuroEngineering and Rehabilitation, 2, pp.5~ (2005)
  4. L.E. Dunne, "A Comparative Evaluation of Bend Sensors for Wearable Applications", IEEE International Symposium on Wearable Computers, pp.121~122 (2007)
  5. R. Gentner, "Development and evaluation of a low-cost sensor glove for assessment of human finger movements in neurophysiological settings", Journal of Neuroscience Methods, 178(1), pp.138~147 (2009)
  6. G. Saggio, "Electrical Resistance Profiling of Bend Sensors Adopted to Measure Spatial Arrangement of the Human Body", 4th International Symposium on Applied Sciences in Biomedical and Communication Technologies (2011)
  7. G. Saggio, "Mechanical model of flex sensors used to sense finger movements", Sensors and Actuators A : Physical, 185, pp.53~58 (2012)
  8. Y. Qi, "Highly sensitive bending sensor based on multimodemultimodecoreoffset fiber structure", Optics & Laser Technology, 75, pp.52~56 (2015)
  9. K. S. C. Kuang, "An evaluation of a novel plastic optical fibre sensor for axial strain and bend measurements", Measurement Science and Technology, 13(10), pp.1523~1534 (2002)
  10. T.G. Zimmerman, "Optical flex sensor, US4542291A", ~ (1985)
  11. Y.L. Harvill, "Motion sensor which produces an asymmetrical signal in response to symmetrical movement, US5097252A", ~ (1992)
  12. Y. Liu, "Optical bend sensor based on measurement of resonance mode splitting of long-period fiber grating", IEEE Photonics Technology Letters, 12(5), pp.531~533 (2000)
  13. S. Chen, "A smart bending sensor with a novel temperature-and strain-insensitive long-period grating", Sensors and Actuators A : Physical, 116(1), pp.103~106 (2004)
  14. Y. Dong, "Novel bending sensor based on a meniscus shaped beam with LPG", Optik-International Journal for Light and Electron Optics, 124(24), pp.6737~6739 (2013)
  15. A. Taghipour, "Comparative study between LPFG-and FBG-based bending sensors", Optics Communications, 312, pp.99105~ (2014)
  16. A. Tognetti, "Wearable Goniometer and Accelerometer Sensory Fusion for Knee Joint Angle Measurement in Daily Life", Sensors, 15(11), pp.28435~28455 (2015)
  17. M. Stoppa, "Wearable Electronics and Smart Textiles : A Critical Review", Sensors, 14(7), pp.1957~11992 (2014)
  18. C. -T. Huang, "A wearable yarn-based piezo-resistive sensor", Sensors and Actuators A : Physical, 141(2), pp.396~403 (2008)
  19. U. Jeong, "Modeling and Design of the Large Deflection Bend Sensor using Length Change of Bowdencable", 31st ICROS Annual Conference, pp.120~121 (2016)
  20. S. J. Phee, "Tendon sheath analysis for estimation of distal end force and elongation for sensorless distal end", Robotica, 28(7), pp.1073~1083 (2010)
  21. B. Bardou, "Improvements in the control of a flexible endoscopic system", IEEE International Conference on Robotics and Automation (ICRA), pp.3725~3732 (2012)
  22. T.N. Do, "Adaptive Control of Position Compensation for CableConduit Mechanisms Used in Flexible Surgical Robots", International Conference on Informatics in Control, Automation and Robotics, pp.110~117 (2014)
  23. S. B. Kesner, "Robotic catheter cardiac ablation combining ultrasound guidance and force control", The International Journal of Robotics Research, 33(4), pp.631~644 (2014)

관련 논문AI추천

이 간행물의 다른 논문 (10건)