부분 손 절단자를 위한 프로토 타입의 손목 회전 모듈 디자인 제안과 상지 움직임의 영향 분석
Design and Analysis of a Wrist Rotation Module Prototype for Partial Hand Amputees: Effects on Upper Limb Movement
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Most partial hand amputees experience limited wrist movement, which hinders the efficient functioning of upper limb, affecting hand-to-use coordination and the usability of the prosthetic hand. This limitation can lead to secondary musculoskeletal issues due to repetitive compensatory movement patterns. However, current partial hand prosthetic lack rotational wrist movement due to challenges in accommodating various hand shapes and limited space. In our study, we proposed a prosthetic hand with a wrist rotation module for partial hand amputees, aiming to reduce compensatory movement. To validate the proposed wrist rotation module, we conducted motion analysis during reach-to-grasp task. Furthermore, during the Jebsen-Taylor hand function test, we evaluated both the effect on upper limb movement and the usability of the prosthetic hand, comparing configurations with and without the wrist rotation module. The results showed that the prosthetic hand equipped with rotational wrist movements reduces compensatory movements and promotes efficient upper limb movement patterns. This finding highlights the value of incorporating a wrist rotation module in prosthetic hands to improve upper limb movement for partial hand amputees.
Abstract
Most partial hand amputees experience limited wrist movement, which hinders the efficient functioning of upper limb, affecting hand-to-use coordination and the usability of the prosthetic hand. This limitation can lead to secondary musculoskeletal issues due to repetitive compensatory movement patterns. However, current partial hand prosthetic lack rotational wrist movement due to challenges in accommodating various hand shapes and limited space. In our study, we proposed a prosthetic hand with a wrist rotation module for partial hand amputees, aiming to reduce compensatory movement. To validate the proposed wrist rotation module, we conducted motion analysis during reach-to-grasp task. Furthermore, during the Jebsen-Taylor hand function test, we evaluated both the effect on upper limb movement and the usability of the prosthetic hand, comparing configurations with and without the wrist rotation module. The results showed that the prosthetic hand equipped with rotational wrist movements reduces compensatory movements and promotes efficient upper limb movement patterns. This finding highlights the value of incorporating a wrist rotation module in prosthetic hands to improve upper limb movement for partial hand amputees.
참고문헌 (24)
- Aviram M. Giladi, "Surgical principles and perspectives on upper extremity amputations", Prosthetic Restoration and Rehabilitation of the Upper and Lower Extremity, Springer Publishing Company[DOI]
- "Oct., Kinesiology of the musculoskeletal system" (2016)[URL]
- Kathryn Ziegler-Graham, "Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050", Archives of Physical Medicine and Rehabilitation, 89(3), pp.422~429 (2008), Elsevier BV[DOI]
- Bartjan Maat, "Passive prosthetic hands and tools", Prosthetics and orthotics international, 42(1), pp.66~74 (2018), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Francesca Cordella, "Literature Review on Needs of Upper Limb Prosthesis Users", Frontiers in Neuroscience, 10 (2016), Frontiers Media SA[DOI]
- N. Dechev, "Multiple finger, passive adaptive grasp prosthetic hand", Mechanism and machine theory, 36(10), pp.1157~1173 (2001)[DOI]
- B. Massa, "Design and development of an underactuated prosthetic hand", Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292), pp.3374~3379 (2002), IEEE
- R. Doshi, "The design and development of a gloveless endoskeletal prosthetic hand", Journal of rehabilitation research and development, 35(4), pp.388~395 (1998)
- A. Kargov, "Development of a Multifunctional Cosmetic Prosthetic Hand", 2007 IEEE 10th International Conference on Rehabilitation Robotics, pp.550~553 (2007), IEEE
- C. Cipriani, "On the Shared Control of an EMG-Controlled Prosthetic Hand: Analysis of User–Prosthesis Interaction", IEEE Transactions on Robotics, 24(1), pp.170~184 (2008), Institute of Electrical and Electronics Engineers (IEEE)[DOI]
- Reza Boostani, "Evaluation of the forearm EMG signal features for the control of a prosthetic hand", Physiological Measurement, 24(2), pp.309~319 (2003), IOP Publishing[DOI]
- Purushothaman Geethanjali, "Myoelectric control of prosthetic hands: state-of-the-art review", Medical Devices: Evidence and Research, Volume 9, pp.247~255 (2016), Informa UK Limited[DOI]
- Sietke G. Postema, "Musculoskeletal Complaints in Transverse Upper Limb Reduction Deficiency and Amputation in The Netherlands: Prevalence, Predictors, and Effect on Health", Archives of Physical Medicine and Rehabilitation, 97(7), pp.1137~1145 (2016), Elsevier BV[DOI]
- Marisol A. Hanley, "Chronic Pain Associated with Upper-Limb Loss", American Journal of Physical Medicine & Rehabilitation, 88(9), pp.742~751 (2009), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Helena Burger, "A survey of overuse problems in patients with acquired or congenital upper limb deficiency", Prosthetics & Orthotics International, 40(4), pp.497~502 (2016), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Federico Montagnani, "Is it Finger or Wrist Dexterity That is Missing in Current Hand Prostheses?", IEEE Transactions on Neural Systems and Rehabilitation Engineering, 23(4), pp.600~609 (2015), Institute of Electrical and Electronics Engineers (IEEE)[DOI]
- Heather E. Williams, "Myoelectric prosthesis users and non-disabled individuals wearing a simulated prosthesis exhibit similar compensatory movement strategies", Journal of NeuroEngineering and Rehabilitation, 18(1) (2021), Springer Science and Business Media LLC[DOI]
- J. ten Kate, "3D-printed upper limb prostheses : a review", Disabil Rehabil Assist Technol, 12(3), pp.300~314 (2017)[DOI]
- Conor Bloomer, "Comparison of DEKA Arm and Body-Powered Upper Limb Prosthesis Joint Kinematics", Archives of Rehabilitation Research and Clinical Translation, 2(3), pp.100057~ (2020), Elsevier BV[DOI]
- Neil M. Bajaj, "State of the Art in Artificial Wrists: A Review of Prosthetic and Robotic Wrist Design", IEEE Transactions on Robotics, 35(1), pp.261~277 (2019), Institute of Electrical and Electronics Engineers (IEEE)[DOI]
- Gu-Cheol Jeong, "On the Design of a Novel Underactuated Robotic Finger Prosthesis for Partial Hand Amputation", 2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR), pp.861~867 (2019), IEEE
- Simon Christensen, "A Novel Shoulder Mechanism with a Double Parallelogram Linkage for Upper-Body Exoskeletons", Wearable Robotics: Challenges and Trends: Proceedings of the 2nd International Symposium on Wearable Robotics, 16, pp.51~56 (2016), Springer International Publishing
- Kimberly L. Kontson, "Assessing kinematic variability during performance of Jebsen-Taylor Hand Function Test", Journal of Hand Therapy, 33(1), pp.34~44 (2020), Elsevier BV[DOI]
- Adam J. Spiers, "Examining the Impact of Wrist Mobility on Reaching Motion Compensation Across a Discretely Sampled Workspace", 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob), pp.819~826 (2018), IEEE