본문 바로가기
KERD
논문KCI 등재

Pilot Study – 고관절 각도 및 각속도 기반 기립(Sit-To-Stand) 및 착석(Stand-To-Sit) 근력 지원 웨어러블 로봇 알고리즘 개발

Pilot Study – Development of Sit-To-Stand and Stand-To-Sit Muscle-Assisted Wearable Robot Algorithms in Elderly Patients with Hip Angle and Angular Velocity

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

In the elderly population, sarcopenia occurs due to physical aging, leading to movement restrictions and loss of function. This results in dependence on daily activities and limitations in participation, ultimately decreasing the overall quality of life. In this study, we propose an algorithm designed to enable patients with sarcopenia to perform sit-to-stand and stand-to-sit movements seamlessly in their daily lives. The algorithm incorporates a wearable robot for muscle support and includes algorithms for standing and seated muscle strength support. To validate the algorithm’s performance, EMG sensors were attached to the Rectus Femoris and Biceps Femoris muscles. The participants underwent two scenarios: one without wearing the device and one with the device providing muscle strength support, performing sit-to-stand and stand-to-sit motions for one minute in each case. The results showed a 16% increase in the EMG peak value of the Rectus Femoris muscle during standing motion (p=0.009). On the right side, there was a roughly 20% decrease (p=0.018) during standing and a 21% decrease (p=0.014) during sitting motion. In the future, we aim to gather additional data to further refine the algorithm. Our goal is to develop an optimal muscle strength support algorithm based on this data, making it applicable for real-life use by patients with sarcopenia.

Abstract

In the elderly population, sarcopenia occurs due to physical aging, leading to movement restrictions and loss of function. This results in dependence on daily activities and limitations in participation, ultimately decreasing the overall quality of life. In this study, we propose an algorithm designed to enable patients with sarcopenia to perform sit-to-stand and stand-to-sit movements seamlessly in their daily lives. The algorithm incorporates a wearable robot for muscle support and includes algorithms for standing and seated muscle strength support. To validate the algorithm’s performance, EMG sensors were attached to the Rectus Femoris and Biceps Femoris muscles. The participants underwent two scenarios: one without wearing the device and one with the device providing muscle strength support, performing sit-to-stand and stand-to-sit motions for one minute in each case. The results showed a 16% increase in the EMG peak value of the Rectus Femoris muscle during standing motion (p=0.009). On the right side, there was a roughly 20% decrease (p=0.018) during standing and a 21% decrease (p=0.014) during sitting motion. In the future, we aim to gather additional data to further refine the algorithm. Our goal is to develop an optimal muscle strength support algorithm based on this data, making it applicable for real-life use by patients with sarcopenia.

참고문헌 (13)

  1. di E. De L, "Aging populations: the health and quality of life of the elderly", La Clinica terapeutica, 162(1), pp.e13~e18 (2011)
  2. 장윤희, "근감소증 노인의 앉은 상태에서 일어서기 동작 시 체간 및 체중심 특성분석: 사례연구", 재활복지공학회논문지, 13(1), pp.85~91 (2019), 한국재활복지공학회[DOI]
  3. Eylem Tütün Yümin, "The effect of functional mobility and balance on health-related quality of life (HRQoL) among elderly people living at home and those living in nursing home", Archives of Gerontology and Geriatrics, 52(3), pp.e180~e184 (2011), Elsevier BV[DOI]
  4. N. B. Alexander, "Rising From a Chair: Effects of Age and Functional Ability on Performance Biomechanics", Journal of Gerontology, 46(3), pp.M91~M98 (1991), Oxford University Press (OUP)[DOI]
  5. L. Wolfson, "Strength is a major factor in balance, gait, and the occurrence of falls", The journals of gerontology. Series A, Biological sciences and medical sciences, 50, pp.64~67 (1995)[DOI]
  6. P. J. Millington, "Biomechanical analysis of the sit-to-stand motion in elderly persons", Archives of physical medicine and rehabilitation, 73(7), pp.609~617 (1992)
  7. Akim Kapsalyamov, "State of the Art Lower Limb Robotic Exoskeletons for Elderly Assistance", IEEE Access, 7, pp.95075~95086 (2019), Institute of Electrical and Electronics Engineers (IEEE)[DOI]
  8. Byungiune Choi, "Development of Adjustable Knee Assist Device for Wearable Robot based on Linkage and Rolling Joint", 2019 IEEE, 2019, 4043~4050[DOI]
  9. Taufiq Nashrulloh, "Pattern of Muscle Activation During Sit to Stand Task in Feet Forward with 80° Knee Flexion using Surface EMG", Proceedings of the 11th National Congress and the 18th Annual Scientific Meeting of Indonesian Physical Medicine and Rehabilitation Association, pp.82~87 (2019), SCITEPRESS - Science and Technology Publications
  10. Siddharth Bhardwaj, "Lower limb rehabilitation using multimodal measurement of sit-to-stand and stand-to-sit task", Disability and Rehabilitation: Assistive Technology, 16(5), pp.438~445 (2019), Informa UK Limited[DOI]
  11. 이미선, "근전도를 이용한 Sorensen 검사시 성인남녀등 근육의 근피로도 분석", 한국전문물리치료학회지, 5(3), pp.63~71 (1998), 한국전문물리치료학회
  12. Denis Brunt, "The effect of foot placement on sit to stand in healthy young subjects and patients with hemiplegia", Archives of Physical Medicine and Rehabilitation, 83(7), pp.924~929 (2002), Elsevier BV[DOI]
  13. 김수민, "앉은 자세에서 일어서기(Sit to stand)과제의 동작시간과 지면반발력 분석", PNF and Movement, 9(1), pp.31~38 (2011), 대한고유수용성신경근촉진법학회

관련 논문AI추천

이 간행물의 다른 논문 (16건)