본문 바로가기
KERD
논문KCI 등재

Potential Efficacy of Multiple-shot Long-pulsed 1,064-nm Nd:YAG in Nonablative Skin Rejuvenation: A Pilot Study

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류의학일반

초록

Medical Lasers; Engineering, Basic Research, and Clinical Application 159 Original Article Potential Efficacy of Multiple-shot Long-pulsed 1,064-nm Nd:YAG in Nonablative Skin Rejuvenation: A Pilot Study Background and Objectives The ultimate goal in current skin rejuvenation practice is to achieve a good result with minimal pain and downtime. Nonablative skin rejuvenation (NSR) is one technique. The efficacy of the long-pulsed 1064 nm Nd:YAG laser (LPNDY) has not been assessed in NSR. Materials and Methods Three target areas were selected (bilateral cheeks and glabellar region) in six volunteer subjects. A LPNDY with an integral skin temperature monitor delivered three stacked shots to each target area (1064 nm, 12 mm spot, 13 J/cm2, 1 Hz) without any skin cooling or anesthesia. The skin temperature was recorded before, during, and after each set of shots using the system monitor and in real-time using a high-sensitivity (±0.001°C) near-infrared video camera. The skin reaction was observed with the naked eye, and pain and discomfort were assessed by the subjects during and after treatment. Results The subjects reported a mild feeling of heat with no discomfort during or after the test treatments. Mild erythema was observed around the treatment areas, without noticeable edema. A series of three ascending skin temperature stepwise peaks, with a decrease in skin temperature towards the baseline after the third shot, was observed consistently. The mean temperatures for shots 1, 2, and 3 for the cheeks were 39.5°C, 42.0°C, and 44.4°C, respectively, and for the glabella, 40.8°C, 43.9°C, and 46.2°C, respectively. Similar ranges were indicated on the system integral temperature monitor. Conclusion A set of three stacked pulses with the LPNDY at a low fluence achieved ideal dermal temperatures to achieve some dermal remodeling but without any downtime or adverse events. The temperature data from the integral thermal sensor matched the video camera measurements with practical accuracy for skin rejuvenation requirements. These data suggest that LPNDY would satisfy the necessary criteria to achieve effective NSR, but further studies will be needed to assess the actual results in clinical practice.

Abstract

Medical Lasers; Engineering, Basic Research, and Clinical Application 159 Original Article Potential Efficacy of Multiple-shot Long-pulsed 1,064-nm Nd:YAG in Nonablative Skin Rejuvenation: A Pilot Study Background and Objectives The ultimate goal in current skin rejuvenation practice is to achieve a good result with minimal pain and downtime. Nonablative skin rejuvenation (NSR) is one technique. The efficacy of the long-pulsed 1064 nm Nd:YAG laser (LPNDY) has not been assessed in NSR. Materials and Methods Three target areas were selected (bilateral cheeks and glabellar region) in six volunteer subjects. A LPNDY with an integral skin temperature monitor delivered three stacked shots to each target area (1064 nm, 12 mm spot, 13 J/cm2, 1 Hz) without any skin cooling or anesthesia. The skin temperature was recorded before, during, and after each set of shots using the system monitor and in real-time using a high-sensitivity (±0.001°C) near-infrared video camera. The skin reaction was observed with the naked eye, and pain and discomfort were assessed by the subjects during and after treatment. Results The subjects reported a mild feeling of heat with no discomfort during or after the test treatments. Mild erythema was observed around the treatment areas, without noticeable edema. A series of three ascending skin temperature stepwise peaks, with a decrease in skin temperature towards the baseline after the third shot, was observed consistently. The mean temperatures for shots 1, 2, and 3 for the cheeks were 39.5°C, 42.0°C, and 44.4°C, respectively, and for the glabella, 40.8°C, 43.9°C, and 46.2°C, respectively. Similar ranges were indicated on the system integral temperature monitor. Conclusion A set of three stacked pulses with the LPNDY at a low fluence achieved ideal dermal temperatures to achieve some dermal remodeling but without any downtime or adverse events. The temperature data from the integral thermal sensor matched the video camera measurements with practical accuracy for skin rejuvenation requirements. These data suggest that LPNDY would satisfy the necessary criteria to achieve effective NSR, but further studies will be needed to assess the actual results in clinical practice.

참고문헌 (17)

  1. Trelles MA, "Laser ablative resurfacing for photorejuvenation based on more than a decade's experience and 1200 patients : personal observations", J Cosmet Dermatol, 2, pp.2~13 (2003)
  2. Sapijaszko MJ, "Er : YAG laser skin resurfacing", Dermatol Clin, 20, pp.87~96 (2002)
  3. Bernstein LJ, "The short-and long-term side effects of carbon dioxide laser resurfacing", Dermatol Surg, 23, pp.519~525 (1997)
  4. Zdinak LA, "Nonablative skin therapies", Ophthalmol Clin North Am, 18, pp.237~248 (2005)
  5. Trelles MA, "Assessment of the efficacy of nonablative longpulsed 1064-nm Nd : YAG laser treatment of wrinkles compared at 2, 4, and 6 months", Facial Plast Surg, 21, pp.145~153 (2005)
  6. Trelles MA, "Combined nonablative skin rejuvenation with the 595-and 1450-nm lasers", Dermatol Surg, 30, pp.1292~1298 (2004)
  7. Hantash BM, "Fractional photothermolysis : a novel aesthetic laser surgery modality", Dermatol Surg, 33, pp.525~534 (2007)
  8. Geronemus RG, "Fractional photothermolysis : current and future applications", Lasers Surg Med, 38, pp.169~176 (2006)
  9. Nelson JS, "What is nonablative photorejuvenation of human skin?", Semin Cutan Med Surg, 21, pp.238~250 (2002)
  10. Levy AS, "Radiofrequency physics for minimally invasive aesthetic surgery", Clin Plast Surg, 43, pp.551~556 (2016)
  11. Fitzpatrick RE, "Depth of vaporization and the effect of pulse stacking with a high-energy, pulsed carbon dioxide laser", J Am Acad Dermatol, 40, pp.615~622 (1999)
  12. Oni G, "An in vivo histopathological comparison of single and double pulsed modes of a fractionated CO2 laser", Lasers Surg Med, 44, pp.4~10 (2012)
  13. Berge U, "Hormetic modulation of dif-ferentiation of normal human epidermal keratinocytes undergoing replicative senescence in vitro", Exp Gerontol, 43, pp.658~662 (2008)
  14. Dierickx CC, "The role of deep heating for noninvasive skin rejuvenation", Lasers Surg Med, 38, pp.799~807 (2006)
  15. Verrico AK, "Expression of the collagen-related heat shock protein HSP47 in fibroblasts treated with hyperthermia or photodynamic therapy", Br J Cancer, 76, pp.719~724 (1997)
  16. Motta MM, "Lower energy and pulse stacking. A safer alternative for skin tightening using fractional CO2 laser", Acta Cir Bras, 31, pp.28~35 (2016)
  17. Lee MS, "Treatment of vaginal relaxation syndrome with an erbium : YAG laser using 90° and 360° scanning scopes : a pilot study & short-term results", Laser Ther, 23, pp.129~138 (2014)

관련 논문AI추천

A randomized, prospective, split-face pilot study to evaluate the safety and efficacy of 532-nm and 1064-nm picosecond-domain neodymium:yttrium-aluminum-garnet lasers using a diffractive optical element for non-ablative skin rejuvenation: clinical and histological evaluation박귀영, 박병철, 박수정, 한혜성, 홍준기대한피부과학회 · Annals of Dermatology2023 · 제35권 제1호In Vivo and Ex Vivo Skin Reactions after Multiple Pulses of 1,064-nm, Microlens Array-type, Picosecond Laser Treatment이상주, Hee Chul Lee, Herin Lyu, Jinyoung Park, Sung Bin Cho, Young Koo Kim대한의학레이저학회 · Medical Lasers2020 · 제9권 제2호Pore and Acne Scar Treatment with a Q-switched Laser Using a Novel Fractional MDF (Multi-depth Focusing) Handpiece: A Pilot StudyHeeChul Lee, Jewan Kaiser Hwang, JinYoung Park대한의학레이저학회 · Medical Lasers2022 · 제11권 제1호Efficacy and Safety of Treatment with Fractional 1,064-nm Picosecond Laser with Diffractive Optic Element for Wrinkles and Acne Scars: A Clinical Study류태의, 서희석, 이충혁, 진은미, 홍승필대한피부과학회 · Annals of Dermatology2021 · 제33권 제3호Novel small spot-high fluence 1,064 nm Q-switched neodymium-doped yttrium aluminum garnet (Q-Nd:YAG) laser toning approach using quadruple pulsing clears epidermal pigmented lesions safely and effectively: case reportsJewan Kaiser Hwang대한의학레이저학회 · Medical Lasers2024 · 제13권 제4호Safety and efficacy of a novel nonablative 1,550 nm fractional laser for the treatment of facial dermatological conditions in Republic of Korea: retrospective clinical studyJewan Kaiser Hwang대한의학레이저학회 · Medical Lasers2025 · 제14권 제4호

이 간행물의 다른 논문 (15건)