The purpose of this study was to compare surface hardness between titanium-nitride coated crowns (TiNCs) and stainless steel crowns (SSCs), and to evaluate the corrosion resistance and color sustainability of TiNCs. Ten TiNCs and 10 SSCs were used for the hardness test. Measurement was performed 30 times for each type of crowns, and the mean values were compared. Metallic raw material plates (before being processed into crowns) of TiNCs and SSCs were prepared for the corrosion resistance test. The total amounts of metal ion releases in the test solution were detected by inductively coupled plasma-optical emission spectrometry. Five TiNCs were subjected to the color sustainability test by applying repetitive brushing forces. The mean hardness values of TiNC group and SSC group were 395.53 ± 105.90 Hv and 278.70 ± 31.45 Hv respectively. Hardness of TiNCs were significantly higher than that of SSCs. The total amounts of metal ion releases from the materials of TiNCs and SSCs satisfied the criterion in International Organization for Standardization 22674. The results mean that TiNCs and SSCs were not harmful in an acidic environment. The golden coating was stable against the repetitive physical stimulations for a given period time.
Abstract
The purpose of this study was to compare surface hardness between titanium-nitride coated crowns (TiNCs) and stainless steel crowns (SSCs), and to evaluate the corrosion resistance and color sustainability of TiNCs. Ten TiNCs and 10 SSCs were used for the hardness test. Measurement was performed 30 times for each type of crowns, and the mean values were compared. Metallic raw material plates (before being processed into crowns) of TiNCs and SSCs were prepared for the corrosion resistance test. The total amounts of metal ion releases in the test solution were detected by inductively coupled plasma-optical emission spectrometry. Five TiNCs were subjected to the color sustainability test by applying repetitive brushing forces. The mean hardness values of TiNC group and SSC group were 395.53 ± 105.90 Hv and 278.70 ± 31.45 Hv respectively. Hardness of TiNCs were significantly higher than that of SSCs. The total amounts of metal ion releases from the materials of TiNCs and SSCs satisfied the criterion in International Organization for Standardization 22674. The results mean that TiNCs and SSCs were not harmful in an acidic environment. The golden coating was stable against the repetitive physical stimulations for a given period time.
참고문헌 (25)
- Berg JH, "The continuum of restorative materials in pediatric dentistry-a review for the clinician", Pediatr Dent, 20, pp.93~100 (1998)
- Croll TP, "Zinc oxide-eugenol pulpotomy and stainless steel crown restoration of a primary molar", Quintessence Int, 23, pp.383~388 (1992)
- Holan G, "Success rate of formocresol pulpotomy in primary molars restored with stainless steel crown vs amalgam", Pediatr Dent, 24, pp.212~216 (2002)
- Kim KC, "Pediatric Dentistry", pp.274~277 (2014), Dental Wisdom
- Fieldman BS, "A simple efficient method for utilizing the stainless steel crown", ASDC J Dent Child, 46, pp.464~469 (1979)
- Puckett SD, "The relationship between the nanostructure of titanium surfaces and bacterial attachment", Biomaterials, 31, pp.706~713 (2010)
- Sterzenbach T, "Bioadhesion in the oral cavity and approaches for biofilm management by surface modifications", Clin Oral Invest, 24, pp.4237~4260 (2020)
- Schaldach M, "Titanium nitride cardiac pacemaker electrodes", Biomed Tech(Berl), 34, pp.185~190 (1989)
- Sin DC, "Surface coatings for ventricular assist devices", Expert Rev Med Devices, 6, pp.51~60 (2009)
- Mezger PR, "Titanium nitride coatings in clinical dentistry", J Dent, 20, pp.342~344 (1992)
- Wisbey A, "Application of PVD TiN coating to Co-Cr-Mo based surgical implants", Biomaterials, 8, pp.477~480 (1987)
- van Hove RP, "Titanium-Nitride Coating of Orthopaedic Implants : A Review of the Literature", BioMed Res Int, 2015, pp.1~9 (2015)
- Attar F, "Hardness evaluation of thin ceramic coatings on tool steel", Surf Coat Technol, 78, pp.78~86 (1996)
- O’Quigley DGF, "New results on the relationship between hardness and fracturetoughness of WC-Co hard metal", Mater Sci Eng, 209, pp.228~230 (1996)
- Behrmann LA, "Effect of Perforations on Fracture Initiation", J Pet Technol, 43, pp.608~615 (1991)
- Roberts JF, "The survival of resin modified glass ionomer and stainless steel crown restorations in primary molars, placed in a specialist paediatric dental practice", Br Dent J, 198, pp.427~431 (2005)
- International Organization for Standardization, "International Standard ISO 22674", ISO, 8~22 (2016)
- Jonsson B, "Hardness measurement of thin films", Thin Solid Films, 114, pp.257~269 (1984)
- Bahrololoomi Z, "Effect of Diode Laser Irradiation Combined with Topical Fluoride on Enamel Microhardness of Primary Teeth", J Dent(Tehran), 12, pp.85~89 (2015)
- Guitierrez MN, "In vitro evaluation of microhardness of amalgam and stainless-steel crowns", Rev Odotopediatr Latinoam, 8, pp.123~130 (2018)
- Owais AI, "Changes in occlusal bite force following placement of preformed metal crowns on primary molars in 4-6 years old children : a 6months' follow-up pilot study", Eur Arch Paediatr Dent, 20, pp.9~14 (2019)
- Wiltshire WA, "Allergies to dental materials", Quintessence Int, 27, pp.513~520 (1996)
- Messer LB, "The durability of primary molar restorations: II. Observations and predictions of success of stainless steel crowns", Pediatr Dent, 10, pp.81~85 (1988)
- "Brushing Your Teeth"[URL]
- Karibe H, "Relation between clenching strength and occlusal force distribution in primary dentition", J Oral Rehabil, 30, pp.307~311 (2003)