초록

The purpose was to reduce the distortion of the image that occurs in the temporal bone area due to the very strong differences in susceptibility. A new SS-TSE technique was applied when examining the diffusion-weighted image of the temporal bone, where the auditory and facial nerves to be imaged were very thin and were adjacent to the cranial base including bone and air. This study was conducted from March 2020 to August of the same year, targeting 32 subjects who underwent the diffusion-weighted imaging of the temporal bone. To compare the distortion, existing SS-EPI technique and the new SS-TSE technique were both applied on the temporal bone area. As a result of the study, applying the new SS-TSE technique appeared to lower the distortion of images by 87.44, 46.13 and 42.35 % on the b-value 0, 800 and the ADC images, respectively. In conclusion, when using the new SS-TSE technique on the temporal bone DWI, distortion can be reduced, and thus images with high diagnostic value can be obtained.

Abstract

The purpose was to reduce the distortion of the image that occurs in the temporal bone area due to the very strong differences in susceptibility. A new SS-TSE technique was applied when examining the diffusion-weighted image of the temporal bone, where the auditory and facial nerves to be imaged were very thin and were adjacent to the cranial base including bone and air. This study was conducted from March 2020 to August of the same year, targeting 32 subjects who underwent the diffusion-weighted imaging of the temporal bone. To compare the distortion, existing SS-EPI technique and the new SS-TSE technique were both applied on the temporal bone area. As a result of the study, applying the new SS-TSE technique appeared to lower the distortion of images by 87.44, 46.13 and 42.35 % on the b-value 0, 800 and the ADC images, respectively. In conclusion, when using the new SS-TSE technique on the temporal bone DWI, distortion can be reduced, and thus images with high diagnostic value can be obtained.

참고문헌 (21)

  1. Burke JF, "Wide variation and rising utilization of stroke magnetic resonance imaging : Data from 11 states", Annals of Neurology, 71(2), pp.179~185 (2012)
  2. Simonsen CZ, "Sensitivity of diffusion-and perfusion-weighted imaging for diagnosing acute ischemic stroke is 97.5%", Stroke, 46(1), pp.98~101 (2015)
  3. Thian YL, "Readout-segmented Echo-planar imaging for diffusion-weighted imaging in the pelvis at 3T—A feasibility study", Academic Radiology, 21(4), pp.531~537 (2014)
  4. 최관우, "자기공명 확산강조영상검사 시 영상왜곡 감소에 관한 연구", 한국방사선학회논문지, 10(4), pp.279~284 (2016), 한국방사선학회[DOI]
  5. Yeom KW, "Comparison of readout-segmented echo-planar imaging(EPI)and single-shot EPI in clinical application of diffusion-weighted imaging of the pediatric brain", American Journal of Roentgenology, 200(5), pp.437~443 (2013)
  6. Holdsworth SJ, "Diffusion-weighted imaging with dual-echo echo-planar imaging for better sensitivity to acute stroke", American Journal of Neuroradiology, 35(7), pp.1293~1302 (2014)
  7. 구노현, "뇌줄기 확산강조 자기공명영상검사 시 뒤틀림을 줄이기 위한 SS-TSE 기법의 신호대잡음비 연구", 한국방사선학회논문지, 10(4), pp.241~246 (2016), 한국방사선학회[DOI]
  8. Porter DA, "High resolution diffusion‐weighted imaging using readout segmented echo‐planar imaging, parallel imaging and a two‐dimensional navigator‐based reacquisition", Magnetic Resonance in Medicine, 62(2), pp.468~475 (2009)
  9. Bammer R, "Basic principles of diffusion-weighted imaging", European Journal of Radiology, 45(3), pp.169~184 (2003)
  10. De Foer B, "Single-shot, turbo spin-echo, diffusion-weighted imaging versus spin-echo-planar, diffusion-weighted imaging in the detection of acquired middle ear cholesteatoma", American Journal of Neuroradiology, 27(7), pp.1480~1482 (2006)
  11. Ishihara T, "Clinical application of multi-shot diffusion EPI in neurological disease", Rinsho Shinkeigaku Clinical Neurology, 38(5), pp.453~456 (1998)
  12. Zhang JS, "Multishot diffusion-weighted MR imaging features in acute trauma of spinal cord", European Radiology, 24(3), pp.685~692 (2014)
  13. Bammer R, "Basic principles of diffusion-weighted imaging", European Journal of Radiology, 45(3), pp.169~184 (2003)
  14. Buonocore MH, "Ghost artifact reduction for echo planar imaging using image phase correction", Magnetic Resonance in Medicine, 38(1), pp.89~100 (1997)
  15. Hennel F, "Image-based reduction of artifacts in multishot echo-planar imaging", Journal of Magnetic Resonance, 134(2), pp.206~213 (1998)
  16. 최관우, "갑상선의 확산강조영상 검사 시 실리콘 이용한 뒤틀림 감소에 관한 연구", 한국산학기술학회논문지, 15(7), pp.4380~4386 (2014), 한국산학기술학회[DOI]
  17. Lövblad KO, "Turbo spi n-echo di ffusion-weighted MR of ischemic stroke", American Journal of Neuroradiology, 19(2), pp.201~208 (1998)
  18. De Graaf P, "Single-shot turbo spin-echo diffusion-weighted imaging for retinoblastoma : Initial experience", American Journal of Neuroradiology, 33(1), pp.110~118 (2012)
  19. Verhappen MH, "Diffusion-weighted MR imaging in head and neck cancer : Comparison between half-fourier acquired single-shot turbo spin-echo and EPI techniques", American Journal of Neuroradiology, 33(7), pp.1239~1246 (2012)
  20. 손순룡, "자기공명영상검사 시 26cm 이하 영상영역의 Multi-Transmit 기법의 유용성", 방사선기술과학, 38(4), pp.429~435 (2015), 대한방사선과학회[DOI]
  21. 최관우, "다중채널코일과 병렬영상기법 이용 시 두영역측정법을 사용한 신호대잡음비 측정의 문제점", 방사선기술과학, 38(4), pp.403~410 (2015), 대한방사선과학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (7건)