본문 바로가기
KERD
논문KCI 등재

Comparison of Setup Deviations for Two Thermoplastic Immobilization Masks in Glottis Cancer

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

The purpose of this study was compare to the patient setup deviation of two different type thermoplastic immobilization masks for glottis cancer in the intensity-modulated radiation therapy (IMRT). A total of 16 glottis cancer cases were divided into two groups based on applied mask type: standard or alternative group. The mean error (M), three-dimensional setup displacement error (3D-error), systematic error (Σ), random error (σ) were calculated for each group, and also analyzed setup margin (mm). The 3D-errors were 5.2 ± 1.3 mm and 5.9 ± 0.7 mm for the standard and alternative groups, respectively; the alternative group was 13.6% higher than the standard group. The systematic errors in the roll angle and the x, y, z directions were 0.8°, 1.7 mm, 1.0 mm, and 1.5 mm in the alternative group and 0.8°, 1.1 mm, 1.8 mm, and 2.0 mm in the alternative group. The random errors in the x, y, z directions were 10.9%, 1.7%, and 23.1% lower in the alternative group than in the standard group. However, absolute rotational angle (i.e., roll) in the alternative group was 12.4% higher than in the standard group. For calculated setup margin, the alternative group in x direction was 31.8% lower than in standard group. In contrast, the y and z direction were 52.6% and 21.6% higher than in the standard group. Although using a modified thermoplastic immobilization mask could be affect patient setup deviation in terms of numerical results, various point of view for an immobilization masks has need to research in terms of clinic issue.

Abstract

The purpose of this study was compare to the patient setup deviation of two different type thermoplastic immobilization masks for glottis cancer in the intensity-modulated radiation therapy (IMRT). A total of 16 glottis cancer cases were divided into two groups based on applied mask type: standard or alternative group. The mean error (M), three-dimensional setup displacement error (3D-error), systematic error (Σ), random error (σ) were calculated for each group, and also analyzed setup margin (mm). The 3D-errors were 5.2 ± 1.3 mm and 5.9 ± 0.7 mm for the standard and alternative groups, respectively; the alternative group was 13.6% higher than the standard group. The systematic errors in the roll angle and the x, y, z directions were 0.8°, 1.7 mm, 1.0 mm, and 1.5 mm in the alternative group and 0.8°, 1.1 mm, 1.8 mm, and 2.0 mm in the alternative group. The random errors in the x, y, z directions were 10.9%, 1.7%, and 23.1% lower in the alternative group than in the standard group. However, absolute rotational angle (i.e., roll) in the alternative group was 12.4% higher than in the standard group. For calculated setup margin, the alternative group in x direction was 31.8% lower than in standard group. In contrast, the y and z direction were 52.6% and 21.6% higher than in the standard group. Although using a modified thermoplastic immobilization mask could be affect patient setup deviation in terms of numerical results, various point of view for an immobilization masks has need to research in terms of clinic issue.

참고문헌 (23)

  1. Mendenhall BWM, "T1-T2N0 Squamous cell carcinoma of the glottic larynx treated with radiation therapy", Journal of Clinical Oncology, 19(20), pp.4029~4036 (2006)
  2. Tiong A, "Outcome following IMRT for T2 glottic cancer: the potential impact of image-guidance protocols on local control", Journal Radiation Oncology, 3(3), pp.267~275 (2014)
  3. Ruchala KJ, "Megavoltage CT on a tomotherapy system", Physics in Medicine and Biology, 44(10), pp.2597~2621 (1999)
  4. Osman SOS, "On-line cone beam CT image guidance for vocal cord tumor targeting", Radiotherapy and Oncology, 93(1), pp.8~13 (2009)
  5. Kaiser A, "Pitch, roll, and yaw variations in patient positioning", International Journal of Radiation Oncology*Biology*Physics, 66(3), pp.949~955 (2006)
  6. Georg D, "Is mask-based stereotactic head-and-neck fixation as precise as stereotactic head fixation for precision radiotherapy?", International Journal of Radiation Oncology*Biology*Physics, 66(4), pp.61~66 (2006)
  7. Gilbeau L, "Comparison of setup accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumors", Radiotherapy and Oncology, 58(2), pp.155~162 (2001)
  8. Fuss M, "Repositioning accuracy of a commercially available thermoplastic mask system", Radiotherapy and Oncology, 71(3), pp.339~345 (2004)
  9. Kim S, "An immobilization system for claustrophobic patients in head-and-neck intensity-modulated radiation therapy", International Journal of Radiation Oncology*Biology*Physics, 59(5), pp.1531~1539 (2004)
  10. Sharp L, "Randomized trial on two types of thermoplastic masks for patient immobilization during radiation therapy for headand-neck cancer", International Journal of Radiation Oncology*Biology*Physics, 61(1), pp.250~256 (2005)
  11. Article O, "Comparison of geometric uncertainities using electronic portal imaging device in focal three-dimensional conformal radiation therapy using different head supports", Journal of Cancer Research and Therapeutics, 4(2) (2008)
  12. Velec M, "Cone-Beam CT Assessment of Interfraction and Intrafraction Setup Error of Two Head-and-Neck Cancer Thermoplastic Masks", International Journal of Radiation Oncology*Biology*Physics, 76(3), pp.949~955 (2010)
  13. Inata H, "Development of a phantom to evaluate the positioning accuracy of patient immobilization systems using thermoplastic mask and polyurethane cradle", Medical Physics, 39(7), pp.4219~4227 (2012)
  14. Amelio D, "Analysis of inter- and intrafraction accuracy of a commercial thermoplastic mask system used for image-guided particle radiation therapy", Journal of Radiation Research, 54(1) (2013)
  15. Li G, "Migration from full-head mask to “ open- face ” mask for immobilization of patients with head and neck cancer", Journal of Applied Clinical Medical Physics, 14(5), pp.1~11 (2013)
  16. 김영록, "Analysis of Automatic Rigid Image-Registration on Tomotherapy", 방사선기술과학, 37(1), pp.37~47 (2014), 대한방사선과학회
  17. Van Herk M, "Errors and Margins in Radiotherapy", Seminars in Radiation Oncology, 14(1), pp.52~64 (2004)
  18. 정재홍, "토모테라피를 이용한 두경부암 방사선치료에서Aid-pillow 사용에 따른 Pitch와 Yaw의 변화 분석", 의학물리, 24(1), pp.54~60 (2013), 한국의학물리학회
  19. 정재홍, "Relevant Reduction Effect with a Modified Thermoplastic Mask of Rotational Error for Glottic Cancer in IMRT", Journal of the Korean Physical Society, 70(3), pp.308~316 (2017), 한국물리학회
  20. van Kranen S, "Setup Uncertainties of Anatomical Sub-Regions in Head-and-Neck Cancer Patients After Offline CBCT Guidance", International Journal of Radiation Oncology*Biology*Physics, 73(5), pp.1566~1573 (2009)
  21. Giske K, "Local setup errors in image-guided radiotherapy for head and neck cancer patients immobilized with a custom-made device", International Journal of Radiation Oncology*Biology*Physics, 80(2), pp.582~589 (2011)
  22. Van Asselen B, "Intrafraction motions of the larynx during radiotherapy", International Journal of Radiation Oncology*Biology*Physics, 56(2), pp.384~390 (2003)
  23. Zhang Q, "Rotation effects on the target-volume margin determination", Physica Medica, 31(1), pp.80~84 (2015)

관련 논문AI추천

Effect of Cooling Temperature on Shrinkage and Pressure-Induced Discomfort in Thermoplastic Head and Neck Immobilization Masks for Radiotherapy김명수, 김영민, 박소현, 신윤성대한체질인류학회 · 해부·생물인류학2025 · 제38권 제4호용적변조회전 방사선치료 시 Set-up 오차에 따른선량 전달 정확성의 평가김상현, 나권우, 박성아, 이주훈, 하광은(사)한국방사선산업학회 · 방사선산업학회지2018 · 제12권 제1호Development of a Tongue Immobilization Device Using a 3D Printer for Intensity Modulated Radiation Therapy of Nasopharyngeal Cancer Patients권동렬, 김동현, 김영비, 김철종, 나초희, 박승규, 안용찬, 오동렬, 주상규, 최유미, 홍채선대한암학회 · Cancer Research and Treatment2021 · 제53권 제1호Carotid-Sparing TomoHelical 3-Dimensional Conformal Radiotherapy for Early Glottic Cancer김진성, 노재명, 서태석, 안용찬, 오동렬, 정광주, 주상규, 홍채선대한암학회 · Cancer Research and Treatment2016 · 제48권 제1호두경부 IMRT 및 VMAT 시 체적 감소가 전산화치료계획에 미치는 영향김가중, 백금문, 엄기천대한방사선과학회 · Journal of Radiological Science and Technology2023 · 제46권 제3호Analysis of Automatic Rigid Image-Registration on Tomotherapy김영록, 김용호, 김은석, 문성권, 민정환, 민철기, 배선현, 서태석, 안재억, 여승구, 임광채, 정재홍, 정주영, 조광환, 최보영대한방사선과학회 · Journal of Radiological Science and Technology2014 · 제37권 제1호

이 간행물의 다른 논문 (19건)