Quantitative Analysis of Bone Mineral Measurements in Different Types of Dual-energy Absorptiometry Systems:Comparison of CT vs DEXA

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Generally assessing bone mineral density (BMD) were performed on dual energy X-ray absorptiometry (DEXA) the same as dual energy CT (DECT) with a rapid-kVp switching. The purpose of this study is to compare the different of BMD value between DEXA and DECT method, and evaluate usefulness of DECT method. Using scanner for BMD measurements were GE, Healthcare Discovery 750 HD for DECT and Hologic QDR 4500W for DEXA. For compare BMD value in each method, scanned lumbar spine phantom and subjects visiting Korean National Cancer Center from April 2015 to December 2015, records of 50 patients. This study was approved by the Institutional Review Board. The mean BMD value measures for spine phantom and for subjects in each scanners presented strong correlation (r=0.948 with p<0.05 for phantom; r=0.635 with p<0.05 and Kendall's tau (τ)=0.46 with p<0.05 for subjects) and linear relationship between DECT and conventional DEXA. DECT technique for BMD measurement will provide a very useful methodology without additional radiation dose.

Abstract

Generally assessing bone mineral density (BMD) were performed on dual energy X-ray absorptiometry (DEXA) the same as dual energy CT (DECT) with a rapid-kVp switching. The purpose of this study is to compare the different of BMD value between DEXA and DECT method, and evaluate usefulness of DECT method. Using scanner for BMD measurements were GE, Healthcare Discovery 750 HD for DECT and Hologic QDR 4500W for DEXA. For compare BMD value in each method, scanned lumbar spine phantom and subjects visiting Korean National Cancer Center from April 2015 to December 2015, records of 50 patients. This study was approved by the Institutional Review Board. The mean BMD value measures for spine phantom and for subjects in each scanners presented strong correlation (r=0.948 with p<0.05 for phantom; r=0.635 with p<0.05 and Kendall's tau (τ)=0.46 with p<0.05 for subjects) and linear relationship between DECT and conventional DEXA. DECT technique for BMD measurement will provide a very useful methodology without additional radiation dose.

참고문헌 (9)

  1. Karaaltıncaba M, "Dual-energy CT revisited with multidetector CT : review of principles and clinical applications", Diagn Interv Radiol, 17(3), pp.181~194 (2011)
  2. Jimenez-Mendoza D, "Single X-ray transmission system for bone mineral density determination", Rev Sci instrum, 82(12), pp.125105~ (2011)[DOI]
  3. Liu X, "Quantitative imaging of element composition and mass fraction using dual-energy CT : Three-material decomposition", Med phys, 36(5), pp.1602~1609 (2009)
  4. Philipp H, "Phantomless bone mineral density (BMD) measurement using dual energy computed tomography-based 3 material decomposition", SPIE (2016)[DOI]
  5. Wait JM, "Performance evaluation of material decomposition with rapid-kilovoltage–switching dual-energy CT and implication for assessing bone mineral density", AJR, 204(6), pp.1234~1241 (2015)
  6. Matsumoto K, "Virtual monochromatic spectral imaging with fast kilovoltage switching : improved image quality as compared with that obtained with conventional 120-kVp CT", Radiology, 259(1), pp.257~262 (2011)
  7. Islamian JP, "Comparison between the MDCT and the DEXA scanners in the evaluation of BMD in the lumbar spine densitometry", The Eguptian journal of radiology and nuclear medicine, 47, pp.961~967 (2016)
  8. Damilakis J, "An update on the assessment of osteoporosis using radiologic techniques", Eur Radiology, 17, pp.1591~1602 (2007)
  9. Graser A, "Dual energy CT : preliminary observations and potential clinical applications in the abdomen", European Radiology, 19(13) (2009)

관련 논문AI추천

국산 이중에너지 방사선흡수 골밀도 장치와 GE Lunar Prodigy의 교차분석 식 도출에 관한 연구김경아, 김정민, 김정수, 노영훈, 이인자, 이인주(사)한국방사선산업학회 · 방사선산업학회지2017 · 제11권 제1호정량적 전산화 단층촬영법(QCT)과 이중에너지 방사선 흡수법(DXA)에 의한 골밀도 측정값 상관분석 연구조동헌한국지식정보기술학회 · 한국지식정보기술학회 논문지2012 · 제7권 제5호Result of Proficiency Test and Comparison of Accuracy Using a European Spine Phantom among the Three Bone Densitometries강현, 김덕윤, 김서화, 김하영, 박기정, 박승환, 박애자, 최지혜, 하용찬대한골대사학회 · 대한골대사학회지2015 · 제22권 제2호이중에너지 X선 흡수계측법(Dual-energy X-ray Absorptiometry, DXA) 골밀도 장비의방사선 피폭선량 평가 및 진단 참고 준위(DRL) 설정김호성(사)한국방사선산업학회 · 방사선산업학회지2025 · 제19권 제2호이중에너지엑스선흡수기 (Dual energy X-ray Absorptiometry: DXA)를 이용한 골밀도검사 결과분석에서 수동분석법의 유용성 평가곽종길, 김은혜, 김호성(사)한국방사선산업학회 · 방사선산업학회지2018 · 제12권 제4호전산화단층영상검사에서 단일에너지와 이중에너지를 이용한 뼈 부피측정의 비교김연민, 김영균, 박상훈대한방사선과학회 · Journal of Radiological Science and Technology2017 · 제40권 제2호

이 간행물의 다른 논문 (19건)