In recent years, demand for examination of bone mineral density (BMD) is increasing in Korea according aging society. Therefore, it is required to develop an efficient management program that can increase the safety and reliability of Dual Energy X-ray Absorptiometry (DXA) that can be applied to the criteria of the World Health Organization. It is necessary to develop a management program that can design a program to improve the accuracy and precision of the results of the analysis and to improve the accuracy of diagnosis of osteoporosis by development a high quality DXA report. It is recommended to prepare the examination manuals and to establish procedures of standard operating including the program to prevent the pitfalls during the examination, the compatibility evaluation of the examination data, and the contents of the radiation safety. In addition, relevant regulations on the production of high-quality DXA reports are required and government and related agencies should introduce individual and facility recognition programs through DXA measurement and education programs and training. It is considered that efforts should be made to prepare high quality DXA report by guidelines on all aspects of BMD for preparation about aging society.

Abstract

In recent years, demand for examination of bone mineral density (BMD) is increasing in Korea according aging society. Therefore, it is required to develop an efficient management program that can increase the safety and reliability of Dual Energy X-ray Absorptiometry (DXA) that can be applied to the criteria of the World Health Organization. It is necessary to develop a management program that can design a program to improve the accuracy and precision of the results of the analysis and to improve the accuracy of diagnosis of osteoporosis by development a high quality DXA report. It is recommended to prepare the examination manuals and to establish procedures of standard operating including the program to prevent the pitfalls during the examination, the compatibility evaluation of the examination data, and the contents of the radiation safety. In addition, relevant regulations on the production of high-quality DXA reports are required and government and related agencies should introduce individual and facility recognition programs through DXA measurement and education programs and training. It is considered that efforts should be made to prepare high quality DXA report by guidelines on all aspects of BMD for preparation about aging society.

참고문헌 (42)

  1. "Daily Medi" (2017)[URL]
  2. Kanis JA, "Assessment of fracture risk and its application to screening for postmenopausal osteoporosis: synopsis of a WHO report. WHO Study Group", Osteoporos Int, 4, pp.368~381 (1994)[DOI]
  3. Bouxsein ML, "Quantifying the material and structural determinants of bone strength", Best Pract Res Clin Rheumatol, 23, pp.741~753 (2009)[DOI]
  4. Lenchik L, "Executive summary International Society for Clinical Densitometry position development conference Denver, Colorado July 20-22, 2001", J Clin Densitom, 5, pp.S1~S3 (2002)[DOI]
  5. Lewiecki EM, "Official positions of the international society for clinical densitometry", The Journal of Clinical Endocrinology & Metabolism, 89(8), pp.3651~3655 (2004)[DOI]
  6. Lewiecki EM, "Common mistakes in the clinical use of bone mineral density testing", Nat Clin Pract Rheumatol, 4, pp.667~674 (2008)[DOI]
  7. Lewiecki EM, "DXA quality matters", J Clin Densitom, 9, pp.388~392 (2006)[DOI]
  8. Watts NB, "Fundamentals and pitfalls of bone densitometry using dual-energy X-ray absorptiometry (DXA)", Osteoporos Int, 15, pp.847~854 (2004)[DOI]
  9. Messina C, "Prevalence and type of errors in dual-energy X-ray absorptiometry", Eur Radiol, 25, pp.1504~1511 (2015)[DOI]
  10. Kim TY, "Variability in DXA Reporting and other challenges in osteoporosis evaluation", JAMA Intern Med, 176, pp.393~395 (2016)[DOI]
  11. Fenton JJ, "Osteoporosis overtreatment in a regional health care system", JAMA Intern Med, 176, pp.391~393 (2016)
  12. 이윤홍, "DEXA를 이용한 골밀도 측정시 검사자의 ROI 변화에 따른 골밀도 측정값의 오차에 관한 연구", 방사선기술과학, 35(1), pp.1~7 (2012), 대한방사선과학회
  13. 김정수, "이중에너지 방사선흡수 골밀도 장치의 품질관리 현황", 방사선기술과학, 39(4), pp.527~534 (2016), 대한방사선과학회[DOI]
  14. Faulkner KG, "Osteoporosis, Two-Volume Set" (2001), Academic Press
  15. "The Writing Group for the International Society for Clinical Densitometry Position Development Conference. Technical standardization for dualenergy X-ray absorptiometry", J Clin Densitom, 7, pp.27~36 (2004)[DOI]
  16. Khan AA, "Standards and guidelines for technologists performing central dualenergy X-ray absorptiometry", J Clin Densitom, 10, pp.189~195 (2007)[DOI]
  17. Bonnick SL, "Bone Densitometry for Technologists" (2013), Springer
  18. Pearson D, "Long-term quality control of DXA: a comparison of Shewhart rules and Cusum charts", Osteoporos Int, 7, pp.338~343 (1997)[DOI]
  19. Bonnick SL, "Bone Densitometry in Clinical Practice: Application and Interpretation" (2010), Humana
  20. Damilakis J, "Radiation exposure in X-ray-based imaging techniques used in osteoporosis", Eur Radiol, 20, pp.2707~2714 (2010)[DOI]
  21. Guglielmi G, "Quality assurance in bone densitometry", Current Radiology Reports, 2(2), pp.1~6 (2014)
  22. Leslie WD, "Minimum sample size requirements for bone density precision assessment produce inconsistency in clinical monitoring", Osteoporos Int, 17, pp.1673~1680 (2006)[DOI]
  23. "International Society for Clinical Densitometry: 2017 ISCD Official Positions;The new official positions of the ISCD as updated in 2017 about phantom scanning, precision assessment and cross-calibration of DXA machines"[URL]
  24. Donnelly LF, "Improving patient safety: effects of a safety program on performance and culture in a department of radiology", AJR Am J Roentgenol, 193, pp.165~171 (2009)[DOI]
  25. Damilakis J, "Embryo", fetus radiation dose and risk from dual X-ray absorptiometry examinations, 2002, pp.13, 716~722
  26. Masud T, "Effect of spinal osteophytosis on bone mineral density measurements in vertebral osteoporosis", BMJ, 307, pp.172~173 (1993)[DOI]
  27. Svendsen OL, "Impact of soft tissue on in vivo accuracy of bone mineral measurements in the spine, hip and forearm: a human cadaveric study", J Bone Miner Res, 10, pp.868~873 (1995)
  28. Phillipov G, "Reproducibility of DXA: potential impact on serial measurements and misclassification of osteoporosis", Osteoporos Int, 12, pp.49~54 (2001)[DOI]
  29. Faulkner KG, "Osteoporosis, Two-Volume Set" (2001), Academic Press
  30. Shepherd JA, "Cross-calibration and minimum precision standards for dual-energy X-ray absorptiometry: the 2005 ISCD official positions", J Clin Densitom, 9, pp.31~36 (2006)[DOI]
  31. Larkin A, "QA", acceptance testing of DEXA X-ray systems used in bone mineral densitometry, 2008, pp.129, 279~283
  32. Blake GM, "Comparison of effective dose to children and adults from dual X-ray absorptiometry examinations", Bone, 38, pp.935~942 (2006)[DOI]
  33. Boudousq V, "Total Dose incurred by patients and staff from BMD measurement using a new 2D digital bone densitometer", Osteoporos. Int., pp.263~269 (2003)
  34. EUROPEAN COMMISSION, "Council Directive 97", 43, Official Journal of the European Communities, pp.1996[DOI]
  35. "EU 2000; Publication 118: Referral Guidelines", ~
  36. "EU 1998; Research Guidelines, Publication 99", ~
  37. Huda W, "Patient doses in bone mineral densitometry", Br. J. Radiol, 69, pp.422~425 (1996)[DOI]
  38. Lewiecki EM, "Best practices for dual-energy X-ray absorptiometry measurement and reporting: International Society for Clinical Densitometry Guidance", J Clin Densitom, 19, pp.127~140 (2016)[DOI]
  39. 김호성, "수도권 지역 병원에서 이중에너지 X-선 흡수측정법 (DXA)을 이용한 골밀도측정기 및 검사자의 정도관리에 관한 연구", 방사선산업학회지, 11(4), pp.283~289 (2017), (사)한국방사선산업학회[DOI]
  40. Watts NB, "Fundamentals and pitfalls of bone densitometry using dual-energy X-ray absorptiometry (DXA)", Osteoporos Int, 15, pp.847~854 (2004)[DOI]
  41. Jergas M, "Current methods and recent advances in the diagnosis of Osteoporosis", Arthritis Rheum, 36, pp.1649~1662 (1993)[DOI]
  42. Johnston CC, "Clinical use of bone densitometry", N Engl J Med, 324, pp.1105~1109 (1991)[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (9건)