This study analyzed dose reduction and quality of images through dose reduction tools and shielding board to protect sensitive eye lens in radiation during orbit CT examinations for clinical data use. During CT scans of the phantom, surface dose (CT scanner dosimetry phantom, ion chamber-3 times) and quality of image (radiosurgery head phantom, visual assessment-2 times, HU standard deviation) were evaluated using X-care which is dose reduction tools and bismuth shielding board. The results of experiments of eight conditions showed a relatively reduced dose in all other conditions compared to when no conditions were set. In particular, the area corresponding to the ophthalmic part reduced the surface dose by up to 45.7 %. The visual evaluation of images by specialists and the quality evaluation of images analyzed by HU standard deviation were clinically closest to the use of X-care and shielding board (1 cm in height). Therefore, it is believed that the use of shielding board in a suitable location with dose reduction tools while investigating the optimal radiation dose will reduce the exposure dose of sensitive lens at radiation while maintaining the quality of the images with high diagnostic value.
Abstract
This study analyzed dose reduction and quality of images through dose reduction tools and shielding board to protect sensitive eye lens in radiation during orbit CT examinations for clinical data use. During CT scans of the phantom, surface dose (CT scanner dosimetry phantom, ion chamber-3 times) and quality of image (radiosurgery head phantom, visual assessment-2 times, HU standard deviation) were evaluated using X-care which is dose reduction tools and bismuth shielding board. The results of experiments of eight conditions showed a relatively reduced dose in all other conditions compared to when no conditions were set. In particular, the area corresponding to the ophthalmic part reduced the surface dose by up to 45.7 %. The visual evaluation of images by specialists and the quality evaluation of images analyzed by HU standard deviation were clinically closest to the use of X-care and shielding board (1 cm in height). Therefore, it is believed that the use of shielding board in a suitable location with dose reduction tools while investigating the optimal radiation dose will reduce the exposure dose of sensitive lens at radiation while maintaining the quality of the images with high diagnostic value.
참고문헌 (35)
- Yu L, "Radiation dose reduction in computed tomography : Techniques and future perspective", Imaging Med, 1(1), pp.65~84 (2009)
- McCollough CH, "Strategies for reducing radiation dose in CT", Radiol Clin North Am, 47(1), pp.27~40 (2009)
- Singh S, "CT radiation dose reduction by modifying primary factors", J Am Coll Radiol, 8(5), pp.369~372 (2011)
- May MS, "Current strategies for dosage reduction in computed tomography", Radiologe, 52(10), pp.905~913 (2012)
- Lai CWK, "Reducing the radiation dose to the eye lens region during CT brain examination : The potential beneficial effect of the combined use of bolus and a bismuth shield", Radioprotection, 50(3), pp.195~201 (2015)
- Colletti PM, "To shield or not to shield : Application of bismuth breast shields", Am J Roentgenol, 200(3), pp.503~507 (2013)
- Kim YK, "Reduced radiation exposure of the female breast during low-dose chest CT using organ-based tube current modulation and a bismuth shield : Comparison of image quality and radiation dose", Am J Roentgenol, 200(3), pp.537~544 (2013)
- Hohl C, "Radiation dose reduction to breast and thyroid during MDCT : Effectiveness of an in-plane bismuth shield", Acta Radiologica, 47(6), pp.562~567 (2006)
- Söderberg M, "Automatic exposure control in computed tomography : An evaluation of systems from different manufacturers", Acta Radiol, 51, pp.625~634 (2010)
- Byun JI, "The analysis for the reduction of radiation dose of breast and lens in eyeballs during the CT examination of cranium and chest using Bismuth shields", Journal of Korean Society of Cumputed Tomographic Technology, 10(1), pp.195~201 (2008)
- Oh HS, "The study of dose reduction effect for eyeball and breast and image evaluation when using X-CARE", Journal of Korean Society of Cumputed Tomographic Technology, 13(2), pp.151~160 (2011)
- Lee K, "Dose reduction and image quality assessment in MDCT using AEC(D-DOM & Z-DOM)and in-plane bismuth shielding", Radiat Prot Dosim, 141(2), pp.162~167 (2010)
- Matsubara K, "A head phantom study for intraocular dose evaluation of 64-slice multidetector CT examination in patients with suspected cranial trauma", Eur J Radiol, 79(2), pp.283~287 (2011)
- Perisinakis K, "Reduction of eye lens radiation dose by orbital bismuth shielding in pediatric patients undergoing CT of the head : a Monte Carlo study", Med Phys, 32(4), pp.1024~1030 (2005)
- 조평곤, "Head CT 검사 시 안구 차폐용 Bismuth사용에 의한 수정체 선량 감소에 대한 평가", 방사선기술과학, 31(2), pp.171~176 (2008), 대한방사선과학회
- Hooper T, "Dose reduction in CT imaging for facial bone trauma in adults : A narrative literature review", J Med Radiat Sci, 66(2), pp.1~11 (2019)
- Lee MY, "CT radiation dose reduction and image quality evaluation in superficial organ:By using bismuth shield and X-care", Journal of Korean Society of Computed Tomographic Technology, 14(2), pp.39~47 (2012)
- Tawfik HA, "Computed tomography of the orbit-A review and an update", Saudi Journal of Ophthalmology, 26(4), pp.409~418 (2012)
- "U.S. exposure to medical radiation soars, ACR issues new white paper on dosage" (2007)[URL]
- Thomton FJ, "Single versus multi-detector row CT : Comparison of radiation doses and dose profiles", Acad Radiol, 10, pp.379~385 (2003)
- Colombo P, "Evaluation of the efficacy of a bismuth shield during CT examinations", Radiol Med, 108, pp.560~568 (2004)
- Goenka AH, "Effect of reduced radiation exposure and iterative reconstruction on detection of low-contrast low-attenuation lesions in an anthropomorphic liver phantom : An 18-reader study", Radiology, 272(1), pp.154~163 (2014)
- Heaney DE, "A comparison of reduction in CT dose through the use of gantry angulations or bismuth shields", Australas Phys Eng Sci Med, 29(2), pp.172~178 (2006)
- Mannudeep K. Kalra, "In-Plane Shielding for CT: Effect of Off-Centering, Automatic Exposure Control and Shield-to-Surface Distance", Korean Journal of Radiology, 10(2), pp.156~163 (2009), 대한영상의학회
- Vollmar SV, "Reduction of dose to the female breast in thoracic CT : A comparison of standard-protocol, bismuth-shielded, partial and tube-current-modulated CT examinations", Eur Radiol, 18(8), pp.1674~1682 (2008)
- Vorona GA, "The use of adaptive statistical iterative reconstruction in pediatric head CT : A feasibility study", Am J Neuroradiol, 34(1), pp.205~211 (2013)
- Owlia M, "Head CT scan overuse in frequently admitted medical patients", American Journal of Medicine, 127(5), pp.406~410 (2014)
- Liao YL, "Bismuth shield affecting CT image quality and radiation dose in adjacent and distant zones relative to shielding surface : A phantom study", Biomedical J, 42(5), pp.343~351 (2019)
- "ICRP Publication 103. The 2007 recommendations of the international commission on radiological protection", Ann ICRP, 37(2-4), pp.1~332 (2007)
- 김민정, "통증 치료에서의 방사선 노출에 의한 눈의 영향과 보호", Anesthesia and Pain Medicine, 12(4), pp.297~305 (2017), 대한마취통증의학회
- Hopper KD, "Orbital, thyroid, and breast superficial radiation shielding for patients undergoing diagnostic CT", Seminars Ultrasound, CT MRI, 23, pp.423~427 (2002)
- Nikupaavo U, "Lens dose in routine head CT : Comparison of different optimization methods with anthropomorphic phantoms", AJR, 204, pp.117~123 (2015)
- Reimann AJ, "Organ-based computed tomographic(CT)radiation dose reduction to the lenses : Impact on image quality for CT of the head", J Comput Assist Tomogr, 36, pp.334~338 (2012)
- 곽영곤, "전산화 단층검사 시 Bismuth와 CARE kV System을 이용한 선량 저감화에 대한 연구", 한국콘텐츠학회 논문지, 14(8), pp.233~242 (2014), 한국콘텐츠학회[DOI]
- 윤재혁, "두경부(Head & Neck) CT 검사 시 장기의 유효선량 측정", 방사선기술과학, 34(2), pp.105~116 (2011), 대한방사선과학회