삼차원 뇌혈관조영술에서 테이블 높이와 확대율 조절에 따른 수정체 선량 감소에 대한 연구

Radiation Dose Reduction of Lens by Adjusting Table Height and Magnification Ratio in 3D Cerebral Angiography

0

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Both angiography and interventional procedures accompanied by angiography provide many diagnostic and therapeutic benefits to patients and are rapidly increasing. However, unlike general radiography or computed tomography using the same X-ray, the amount of radiation is quite high, but the dose range can vary considerably for each patient and operator. The high sensitivity of the lens to radiation during cerebral angiography and neurointervention is already well known, and although there are many related studies, it is insufficient to easily reduce radiation in diagnosis and treatment. In this situation, in particular, by adding three-dimensional rotational angiography (3D-RA) to the existing two-dimensional (2D) angiography, it is now possible to make an accurate diagnosis. However, since this 3D-RA acquires images through projection of more radiation than before, the exposure dose of the lens may be higher. Therefore, we tried to analyze whether the radiation dose of the lens can be reduced by moving the lens out of the field range by adjusting the table height and magnification ratio during the examination using 3D-RA. The surface dose was measured using a rando phantom and a radiophotoluminescent glass dosimeter (PLD) and the radiation dose was compared by adjusting the table height and magnification ratio based on the central point. As a result, it was found that the radiation dose of the lens decreased as the table height increased from the central point, that is, as the lens was out of the field of view. In conclusion, in 3D-RA, moving the table position of about 2 cm in height will make a significant contribution to the dose reduction of the lens, and it was confirmed that adjusting the magnification ratio can also reduce the surface dose of the lens.

Abstract

Both angiography and interventional procedures accompanied by angiography provide many diagnostic and therapeutic benefits to patients and are rapidly increasing. However, unlike general radiography or computed tomography using the same X-ray, the amount of radiation is quite high, but the dose range can vary considerably for each patient and operator. The high sensitivity of the lens to radiation during cerebral angiography and neurointervention is already well known, and although there are many related studies, it is insufficient to easily reduce radiation in diagnosis and treatment. In this situation, in particular, by adding three-dimensional rotational angiography (3D-RA) to the existing two-dimensional (2D) angiography, it is now possible to make an accurate diagnosis. However, since this 3D-RA acquires images through projection of more radiation than before, the exposure dose of the lens may be higher. Therefore, we tried to analyze whether the radiation dose of the lens can be reduced by moving the lens out of the field range by adjusting the table height and magnification ratio during the examination using 3D-RA. The surface dose was measured using a rando phantom and a radiophotoluminescent glass dosimeter (PLD) and the radiation dose was compared by adjusting the table height and magnification ratio based on the central point. As a result, it was found that the radiation dose of the lens decreased as the table height increased from the central point, that is, as the lens was out of the field of view. In conclusion, in 3D-RA, moving the table position of about 2 cm in height will make a significant contribution to the dose reduction of the lens, and it was confirmed that adjusting the magnification ratio can also reduce the surface dose of the lens.

참고문헌 (19)

  1. Song Y, "Estimated radiation dose according to the craniocaudal angle in cerebral digital subtraction angiography : Patient and phantom study", J Neuroradiol, 46, pp.345~350 (2019)
  2. Moritake T, "Dose measurement on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters", AJNR Am J Neuroradiol, 29(10), pp.1910~1917 (2008)
  3. Lakhan SE, "The interventionalism of medicine : Interventional radiology, cardiology, and neuroradiology", Int Arch Med, 2(1), pp.27~ (2009)
  4. Stewart FA, "ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs–threshold doses for tissue reactions in a radiation protection context", Annals of the ICRP, 41, pp.1~322 (2012)
  5. Sandborg M, "Local skin and eye lens equivalent doses in interventional neuroradiology", Eur Radiol, 20(3), pp.725~733 (2010)
  6. Van Strijen MJ, "Evaluation of a noise reduction imaging technology in iliac digital subtraction angiography: Noninferior clinical image quality with lower patient and scatter dose", J Vasc Interv Radiol, 26(5), pp.642~650.e1 (2015)[DOI]
  7. Safari MJ, "Real-time eye lens dose monitoring during cerebral angiography procedures", Eur Radiol, 26(1), pp.79~86 (2016)
  8. Sanchez RM, "Radiation Doses in Patient Eye Lenses during Interventional Neuroradiology Procedures", AJNR Am J Neuroradiol, 37(3), pp.402~407 (2016)
  9. 송윤선, "Low-Dose Fluoroscopy Protocol for Diagnostic Cerebral Angiography", Neurointervention, 15(2), pp.67~73 (2020), 대한신경중재치료의학회[DOI]
  10. Anam C, "The impact of head miscentering on the eye lens dose in CT scanning : Phantoms study", Journal of Physics : Conference Series, 1204(1), pp.012022~ (2019)
  11. 권대철, "엑스선의 조사시간에 따른 형광유리선량계의 빌드업 특성", 의공학회지, 38(5), pp.256~263 (2017), 대한의용생체공학회
  12. Kim S, "Kerma area product method for effective dose estimation during lumbar epidural steroid injection procedures : Phantom study", AJR Am J Roentgenol, 192(6), pp.1726~1730 (2009)
  13. Büermann L, "Air-kerma cavity standards", Metrologia, 46(2), pp.S24~ (2009)
  14. Guenego A, "Proposed achievable levels of dose and impact of dose-reduction systems for thrombectomy in acute ischemic stroke:An international, multicentric, retrospective study in 1096 patients", Eur Radiol, 29(7), pp.3506~3515 (2019)
  15. 주영철, "늑골 방사선검사 시 X선관 초점-영상수신체간 거리에 따른 환자선량과 화질의 연관성 평가", 방사선기술과학, 41(5), pp.391~396 (2018), 대한방사선과학회[DOI]
  16. Schernthaner RE, "Characteristics of a New X-Ray Imaging System for Interventional Procedures : Improved Image Quality and Reduced Radiation Dose", Cardiovasc Intervent Radiol, 41(3), pp.502~508 (2018)
  17. Quantities and Units in Radiation Protection Dosimetry, , ICRU, ~, pp.ICRU Report 51 (1993)
  18. 이나래, "다중소자 열형광선량계에 의한 수정체 등가선량 평가의 적정성 연구", 방사선방어학회지, 37(2), pp.96~102 (2012), 테스트학회[DOI]
  19. 김계선, "Digital Chest Tomosynthesis에서 부가필터에 따른 화질 및 유효선량", 방사선기술과학, 38(4), pp.347~353 (2015), 대한방사선과학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (7건)