본문 바로가기
KERD
논문KCI 등재

몬테카를로 시뮬레이션 기반 밀도에 따른 다양한 검출기 물질을 적용한 획득 영상 평가

Evaluation of Image Quality by Using Various Detector Materials according to Density : Monte Carlo Simulation Study

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

The detector performance is important role in acquiring the gamma rays from patients. Among parameters of detector performances, there is density, which relates to respond to gamma rays. Therefore, we confirm the detection efficiency according to various detector materials based on the density parameter using GATE (geant4 application for emission tomography) simulation tool. The NaI (density: 3.67 g/cm3), CZT (Cadimium Zinc Telluride) (density: 5.80 g/cm3), CdTe (Cadmium Telluride) (5.85 g/cm3), and GAGG (Gadoinium Aluminum Gallium Garnet) (density g/cm3) were used as detector materials. In addition, the point source and quadrant bar phantom, which is modeled for 0.5, 1.0, 1.5, and 2.0 mm thicknesses, were modeled to confirm the quatitative analysis using sensitivity (cps/MBq) and the full width at half maximum (FWHM, mm) at the 2.0 mm bar thickness containing visual evaluation. Based on the results, the sensitivity for NaI, CZT, CdTe, and GAGG detector materials were 0.12, 0.15, 0.16, and 0.18 cps/MBq. In addition, the FWHM for quadrant bar phantom in the 2.0 mm bar thickness is 3.72, 3.69, 3.70, and 3.73 mm for NaI, CZT, CdTe, and GAGG materials, respectively. Compared with performance of detector materials according to density, the high density can improve detection efficiency in terms of sensitivity and mean count. Among these detector materials, the GAGG material is efficient for detection of gamma rays.

Abstract

The detector performance is important role in acquiring the gamma rays from patients. Among parameters of detector performances, there is density, which relates to respond to gamma rays. Therefore, we confirm the detection efficiency according to various detector materials based on the density parameter using GATE (geant4 application for emission tomography) simulation tool. The NaI (density: 3.67 g/cm3), CZT (Cadimium Zinc Telluride) (density: 5.80 g/cm3), CdTe (Cadmium Telluride) (5.85 g/cm3), and GAGG (Gadoinium Aluminum Gallium Garnet) (density g/cm3) were used as detector materials. In addition, the point source and quadrant bar phantom, which is modeled for 0.5, 1.0, 1.5, and 2.0 mm thicknesses, were modeled to confirm the quatitative analysis using sensitivity (cps/MBq) and the full width at half maximum (FWHM, mm) at the 2.0 mm bar thickness containing visual evaluation. Based on the results, the sensitivity for NaI, CZT, CdTe, and GAGG detector materials were 0.12, 0.15, 0.16, and 0.18 cps/MBq. In addition, the FWHM for quadrant bar phantom in the 2.0 mm bar thickness is 3.72, 3.69, 3.70, and 3.73 mm for NaI, CZT, CdTe, and GAGG materials, respectively. Compared with performance of detector materials according to density, the high density can improve detection efficiency in terms of sensitivity and mean count. Among these detector materials, the GAGG material is efficient for detection of gamma rays.

참고문헌 (18)

  1. Zai P, "Role of optimal quantification of FDG PET imaging in the clinical practice of radiology", RadioGraphics, 36, pp.481~496 (2016)
  2. Tsubakimoto M, "Quantitative CT density histogram values and standardized uptake values of FDG-PET", CT with respiratory gating can distinguish solid adenocarcinomas from squamous cell carcinomas of the lung, 2018, pp.100, 108~115
  3. Anger HO, "Scitillation camera with multichannel collimatgors", Journal of Nuclear Medicine, 5, pp.515~531 (1964)
  4. Townsed DW, "Multimodality imaging of structure and function", Physics in Medicine & Biology, 53, pp.1~39 (2008)
  5. Madsen MT, "Recent advances in SPECT imaging", Journal of Nuclear Medicine, 48, pp.661~673 (2007)
  6. 김정수, "GAGG 섬광체 물질을 적용한 감마카메라 영상의 유용성 평가: 몬테 카를로 시뮬레이션 연구", 한국방사선학회논문지, 14(5), pp.511~515 (2020), 한국방사선학회[DOI]
  7. Erlandsson K, "Performance evaluation of D-SPECT : A novel SPECT system for nuclear cardiology", Physics in Medicine & Biology, 54, pp.2635~ (2009)
  8. Lamare F, "Validation of a Monte Carlo simulation of the Philips Allegro", GEMINI PET systems using GATE, 2006, pp.51, 943~
  9. Chen CL, "Integration of SimSET photon history generator in GATE for efficient Monte Carlo simulations of pinhole SPECT", Medical Physics, 35, pp.3278~3284 (2008)
  10. Takahashi A, "A Monte Carlo study on 223Ra imaging for unsealed radionuclide therapy", Medical Physics, 43, pp.2965~2974 (2016)
  11. Mok GSP, "Development and validation of a Monte Carlo simulation tool for multi-pinhole SPECT", Molecular Imaging and Biology, 12, pp.295~304 (2010)
  12. 박찬록, "Similarity analysis of gamma images based on a pixelated CdTe semiconductor detector system using a quadrant bar phantom for nuclear medicine: Monte Carlo simulation study", Nuclear Engineering and Technology, 53(6), pp.1947~1954 (2021), 한국원자력학회[DOI]
  13. Starck S, "The use of detective quantum efficiency(DQE)in evaluaing the performance of gamma camera systems", Physics in Medicine & Biology, 50, pp.1601~ (2005)
  14. 배상일, "몬테칼로 시뮬레이션을 활용한 양성자가속기 단기사용 시 구성품의 방사화 평가", 방사선기술과학, 43(5), pp.389~395 (2020), 대한방사선과학회
  15. 장은성, "몬테카를로 시뮬레이션에서의 다양한 환경 샘플에 대한 Marinelli 비이커 측정 및 자기 흡수 보정과 적용", 방사선기술과학, 40(4), pp.605~611 (2017), 대한방사선과학회[DOI]
  16. Staelens S, "Monte Carlo simulations of a scintillation camera using GATE : Validation and application modelling", Physics in Medicine and Biology, 48, pp.3021~ (2003)
  17. Ashoor M, "Evaluation of crystals' morphology on detection efficiency using modern classification criterion and Monte Carlo method in nuclear medicine", Proceedings of the National Academy of Sciences of the United States of America, 89, pp.579~585 (2019)
  18. Wagennar DJ, "Planar image quality comparison between a CdZnTe prototype and a standard NaI(Tl)gamma camera", Nuclear Instruments and Methods in Physics Research A, 505, pp.586~589 (2003)

관련 논문AI추천