Evaluation of TlBr semiconductor detector in gamma camera imaging: Monte Carlo simulation study
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Among the detector materials available at room temperature, thallium bromide (TlBr), which has a relatively high atomic number and density, is widely used for gamma camera imaging. This study aimed to verify the usefulness of TlBr through quantitative evaluation by modeling detectors of various compound types using Monte Carlo simulations. The Geant4 application for tomographic emission was used for simulation, and detectors based on cadmium zinc telluride and cadmium telluride materials were selected as a comparison group. A pixel-matched parallel-hole collimator with proven excellent performance was modeled, and phantoms used for quality control in nuclear medicine were used. The signal-to-noise ratio (SNR), contrast to noise ratio (CNR), sensitivity, and full width at half maximum (FWHM) were used for quantitative analysis to evaluate the image quality. The SNR, CNR, sensitivity, and FWHM for the TlBr detector material were approximately 1.05, 1.04, 1.41, and 1.02 times, respectively, higher than those of the other detector materials. The SNR, CNR and sensitivity increased with increasing detector thickness, but the spatial resolution in terms of FWHM decreased. Thus, we demonstrated the feasibility and possibility of using the TlBr detector material in comparison with commercial detector materials.
Abstract
Among the detector materials available at room temperature, thallium bromide (TlBr), which has a relatively high atomic number and density, is widely used for gamma camera imaging. This study aimed to verify the usefulness of TlBr through quantitative evaluation by modeling detectors of various compound types using Monte Carlo simulations. The Geant4 application for tomographic emission was used for simulation, and detectors based on cadmium zinc telluride and cadmium telluride materials were selected as a comparison group. A pixel-matched parallel-hole collimator with proven excellent performance was modeled, and phantoms used for quality control in nuclear medicine were used. The signal-to-noise ratio (SNR), contrast to noise ratio (CNR), sensitivity, and full width at half maximum (FWHM) were used for quantitative analysis to evaluate the image quality. The SNR, CNR, sensitivity, and FWHM for the TlBr detector material were approximately 1.05, 1.04, 1.41, and 1.02 times, respectively, higher than those of the other detector materials. The SNR, CNR and sensitivity increased with increasing detector thickness, but the spatial resolution in terms of FWHM decreased. Thus, we demonstrated the feasibility and possibility of using the TlBr detector material in comparison with commercial detector materials.
참고문헌 (36)
- H. O. Anger, "Scintillation camera", Review of Scientific Instruments, 29, pp.27~33 (1958)
- M. T. Madsen, "Recent advances in SPECT imaging", Journal of Nuclear Medicine, 48, pp.661~673 (2007)
- R. J. Jaszczak, "The early years of single photon emission computed tomography (SPECT): an anthology of selected reminiscences", Physics in Medicine and Biology, 51, pp.99~115 (2006)[DOI]
- K. Ogawa, "Image distortion and correction in single photon emission CT", Annals of Nuclear Medicine, 18, pp.171~185 (2004)
- 이영진, "The Effect of High-resolution Parallel-hole Collimator Materials with a Pixelated Semiconductor SPECT System at Equivalent Sensitivities: Monte Carlo Simulation Studies", Journal of the Korean Physical Society, 64(7), pp.1055~1062 (2014), 한국물리학회
- T. E. Peterson, "SPECT detectors: The Anger camera and beyond", Physics in Medicine and Biology, 26, pp.R145~ (2011)[DOI]
- B. D. Milbrath, "Radiation detector materials : An overview", Journal of Materials Re-search, 23, pp.2561~2581 (2008)
- M. Khoshakhlagh, "Development of scintillators in nuclear medicine", World journal of Nuclear Medicine, 14, pp.156~159 (2015)
- I. Mroi, "The CdTe detector module and its imaging performance", Annals of Nuclear Medicine, 15, pp.487~494 (2001)
- M. Rizzi, "Semiconductor detectors and principles of radiation-mater interaction", Journal of Applied Sciences, 10, pp.3141~3155 (2010)
- S. Del Sordo, "Progress in the development of CdTe and CdZnTe semiconductor radiation detectors for astrophysical and medical applications", Sensors, 9, pp.3491~3526 (2009)
- O. Limousin, "New trends in CdTe and CdZnTe detectors for X-and gamma-ray applications", Nuclear Instruments and Methods in Physics Research Section A, 504, pp.24~37 (2003)
- R. N. Beck, "Aspects of imaging and counting in nuclear medicine using scintillation and semiconductor detectors", IEEE Transactions on Nuclear Science, 3, pp.173~178 (1972)
- H. B. Barber, "Applications of semiconductor detectors to nuclear medicine", Nuclear Instruments and Methods in Physics Research Section A, 436, pp.102~110 (1999)
- C. Scheiber, "Medical applications of CdTe and CdZnTe detectors", Nuclear Instruments and Methods in Physics Research Section A, 458, pp.12~25 (2001)
- P. J. Sellin, "Recent advances in compound semiconductor radiation detectors", Nuclear Instruments and Methods in Physics Research Section A, 513, pp.332~339 (2003)
- J. J. Griesmer, "Performance evaluation of a new CZT detector for nuclear meidicne: Soltice", 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310), 2002, pp.1050~1054 (2002)
- L. K. Jambi, "Evaluation of XRI-UNO CdTe detector for nuclear medical imaging", Journal of Instrumentation, 10, pp.P06012~ (2015)
- K. Erlandsson, "Performance evaluation of D-SPECT : a novel SPECT system for nuclear cardiology", Physics in Medicine and Biology, 54, pp.2635~2649 (2009)
- 이영진, "Optimization of a High-resolution Collimator for a CdTe Detector: Monte Carlo Simulation Studies", Journal of the Korean Physical Society, 60(5), pp.862~868 (2012), 한국물리학회
- T. Takahashi, "Recent progress in CdTe and CdZnTe detectors", IEEE Transactions on Nuclear Science, 48, pp.950~959 (2001)
- K. Ogawa, "Development of an ultra-high resolution SPECT system with a CdTe semiconductor detector", Annals of Nuclear Medicine, 23, pp.763~770 (2009)
- L. Verger, "Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications", Nuclear Instruments and Methods in Physics Research Section A, 458, pp.297~309 (2001)
- 박수진, "Ultra-high-resolution SPECT with CdTe for Small-animal Imaging Applications: A Monte Carlo Simulation Study Using A Voxelized Phantom", Journal of the Korean Physical Society, 60(7), pp.1145~1149 (2012), 한국물리학회[DOI]
- K. Hitomi, "Recent development of TlBr Gamma-Ray detectors", IEEE Transactions on Nuclear Science, 58, pp.1987~1991 (2011)
- D. Ari~no-Estrada, "Development of TlBr detectors for PET imaging", Physics in Medicine and Biology, 63, pp.13~ (2018)[DOI]
- H. Kim, "Developing larger TlBr detec-tors-detector performance", IEEE Transactions on Nuclear Science, 56, pp.819~823 (2009)
- K. Hitomi, "A methods for suppressing polarization phenomena in TlBr detectors", Nuclear Instruments and Methods in Physics Research Section A, 585, pp.102~104 (2008)
- C. R. Park, "Similarity analysis of pixelated CdTe semiconductor gamma camera image using a quadrant bar phantom for nuclear medicine : Monte Carlo simulation simulation study", Nuclear Engineering and Technology, 53, pp.1947~1954 (2001)
- J. S. Nabipour, "Spectroscopy and optimizing semiconductor detector data under X and g photons using im-age processing technique", Journal of Medical Imaging and Radiation Sciences, 49, pp.194~200 (2018)
- S. Abbaspour, "Cadmium telluride semiconductor detector for improved spatial and energy resolution radioisotopic imaging", World Journal of Nuclear Medicine, 16, pp.101~107 (2017)
- K. Hitomi, "Advances in TlBr detector development", Journal of Crystal Growth, 379, pp.93~98 (2013)
- C. R. Park, "Optimization of mask size with median modified Wiener filter algorithm for gamma imag-es using pixelated semiconductor detector : Monte Carlo simulation study", Nuclear Instruments and Methods in Physics Research Section A, 980, pp.164472~ (2020)
- 류현주, "Design of a High-resolution Small-animal SPECT-CT System Sharing a CdTe Semiconductor Detector", Journal of the Korean Physical Society, 61(1), pp.130~134 (2012), 한국물리학회[DOI]
- 이영진, "Comparison of Photon Counting and Conventional Scintillation Detectors in a Pinhole SPECT System for Small Animal Imaging: Monte Carlo Simulation Studies", Journal of the Korean Physical Society, 62(9), pp.1317~1322 (2013), 한국물리학회
- M. Kolstein, "Simulation of charge transport in pixelated CdTe", Journal of Instrumentation, 9, pp.C12027~ (2014)
