뇌혈관 직경측정을 위한 3차원 회전 혈관조영술의 유용성

Usefulness of 3D Rotational Angiography for Cerebral Vascular Diameter Measurement

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류방사선과학

초록

When measuring cerebrovascular with 3D rotational angiography, the accuracy was verified by comparing the actual size and measurement size, respectively. It is intended to help select therapeutic materials and instruments during cerebrovascular intervention by comparing the average error rates for measured values in the 3DRA and CTA methods by examining with protocols such as brain CTA, which are always performed in emergency situations. The mean error rate between the groups of measurers was ±3.655% for radiation technologist and ±3.331% for university students, and the mean error rate of the student group was within tolerance (±10%), and the independent sample T-test result t =0.879, p=0.394 (p>0.05) showed no statistically difference between the two. In addition, the average error rate measured by both groups by 3DRA was measured below ±5% within the tolerance error rate (±10%), and most of CTA was measured within the tolerance range (±10%), but showed an average error rate of up to 5.65%, and the independent sample T-test result was statistically more accurate than 3DRA. Both the 3DRA method and the brain CTA method for measuring cerebrovascular size could be accurately measured within tolerance, but it would be better to measure cerebrovascular blood vessels using a more accurate 3DRA method during cerebrovascular intervention.

Abstract

When measuring cerebrovascular with 3D rotational angiography, the accuracy was verified by comparing the actual size and measurement size, respectively. It is intended to help select therapeutic materials and instruments during cerebrovascular intervention by comparing the average error rates for measured values in the 3DRA and CTA methods by examining with protocols such as brain CTA, which are always performed in emergency situations. The mean error rate between the groups of measurers was ±3.655% for radiation technologist and ±3.331% for university students, and the mean error rate of the student group was within tolerance (±10%), and the independent sample T-test result t =0.879, p=0.394 (p>0.05) showed no statistically difference between the two. In addition, the average error rate measured by both groups by 3DRA was measured below ±5% within the tolerance error rate (±10%), and most of CTA was measured within the tolerance range (±10%), but showed an average error rate of up to 5.65%, and the independent sample T-test result was statistically more accurate than 3DRA. Both the 3DRA method and the brain CTA method for measuring cerebrovascular size could be accurately measured within tolerance, but it would be better to measure cerebrovascular blood vessels using a more accurate 3DRA method during cerebrovascular intervention.

참고문헌 (15)

  1. Yoon PH, "Endovascular Treatment of Cerebral Aneurysm", The Korean Neurocritical Care Society, 2(Supply2), pp.74~79 (2009)
  2. 김승기, "혈관조영장비의 테이블-피사체간 거리 변화에 따른 혈관측정 정확도 연구", 방사선기술과학, 42(6), pp.435~440 (2019), 대한방사선과학회
  3. Hirai T, "Prospective evaluation of suspected stenooculusive disease of the intracranial artery : Combined MR angiography and CT angiography compared with distal subtraction angiography", AJNR Am J Neuroradiol, 23, pp.93~101 (2002)
  4. Chung TS, "Evaluation of cerebral aneurysms with high resolution MR angiography using a section interpolation technique;Correlation with digital subtraction angiography", AJNR Am J Neuroradiol, 20(2), pp.229~235 (1999)
  5. Leung DA, "Contrast-Enhanced, three-dimensional MR angiography", Radiology, 200, pp.569~571 (1996)
  6. 윤종태, "삼차원 뇌혈관조영술에서 테이블 높이와 확대율 조절에 따른 수정체 선량 감소에 대한 연구", 방사선기술과학, 45(4), pp.313~320 (2022), 대한방사선과학회
  7. Hirai T, "Clinical Usefulness of Unsubtracted 3D Digital Angiography Compared with Rotational Digital Angiography in the Pretreatment Evaluation of Intracranial Aneurysms", AJNR Am J Neuroradiol, 24(6), pp.1067~1074 (2003)
  8. Hpchmuth A, "Pancreas Allografts : Comparison of Three-dimensional Rotational Angiography with Digital Subtraction Angiography in the assessment of ruptured cerebral aneurysms", AJNR Am J Neuroradiol, 23(7), pp.1199~1205 (2002)
  9. "Product Manual: Xtravision Calibration and verification", Koninklijke Philips Electronics, N.V, ~ (2008)
  10. Sugahara T, "Comparison of 2D and 3D digital subtraction angiography in evaluation of intracranial aneurysms", AJNR Am J Neuroradiol, 23(9), pp.1545~1552 (2002)
  11. Kiyosue H, "Anatomic features predictive of complete aneurysm occlusion can be determined with three-dimensional digital subtraction angiography", AJNR Am J Neuroradiol, 23(7), pp.1206~1213 (2002)
  12. Hochmuth A, "Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms", AJNR Am J Neuroradiol, 23(7), pp.1199~1205 (2002)
  13. Anxionnat R, "Intracranial aneurysms : Clinical value of 3D digital subtraction angiography", Radiology, 218(3), pp.799~808 (2001)
  14. Kim BJ, "Usefulness of CT Angiography in Patients with Intracranial Occlusive Vascular Disease of the Circle of Willis : Comparison with Conventional Angiography", Journal of the Korean Radiological Society, 35(3), pp.301~306 (1996)
  15. 강현수, "뇌 동맥류 진단에 있어 디지털 감산 혈관조영술과 다중검출기 전산화단층촬영 혈관조영술의 유용성 비교", 의학물리, 22(4), pp.184~189 (2011), 한국의학물리학회

관련 논문AI추천

이 간행물의 다른 논문 (7건)