실리콘 혼합 차폐체의 개발과 성능비교
Development and Performance Comparison of Silicon Mixed Shielding Material
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
A shield was made by mixing materials such as bismuth(Bi) and barium(Ba) with silicon to evaluate its shielding ability. Bismuth was made into a shield by mixing a bismuth oxide(Bi2O3) colloidal solution and a silicon base and applied to a fibrous fabric, and barium was made by mixing lead oxide(PbO) and barium sulfate(BaSO4) with a silicon curing agent and solidifying it to make a shield. The test was conducted according to the lead equivalent test method for X-ray protective products of the Korean Industrial Standard. The experiment was conducted by increasing the shielding body one by one from the test condition of 60 kVp, 200 mA, 0.1sec and 100 kVp, 200 mA, 0.1 sec. At 60 kVp, 2 lead oxide-barium sulfate shields, 2 bismuth oxide 1.5 mm shields, and 5 bismuth oxide 0.3 mm shields showed shielding ability equal to or higher than that of lead 0.5 mm. At 100 kVp, 2 lead oxide-barium sulfate shields and 2 bismuth oxide 1.5 mm shields showed shielding ability equal to or higher than that of lead 0.5 mm. It was confirmed that when using 2 pieces of lead oxide-barium sulfate and 1.5 mm of bismuth oxide, respectively, it has shielding ability equivalent to that of lead. Bismuth oxide and lead oxide-barium sulfate are lightweight and have excellent shielding ability, thus they have excellent properties to be used as an apron for radiation protection or other shielding materials.
Abstract
A shield was made by mixing materials such as bismuth(Bi) and barium(Ba) with silicon to evaluate its shielding ability. Bismuth was made into a shield by mixing a bismuth oxide(Bi2O3) colloidal solution and a silicon base and applied to a fibrous fabric, and barium was made by mixing lead oxide(PbO) and barium sulfate(BaSO4) with a silicon curing agent and solidifying it to make a shield. The test was conducted according to the lead equivalent test method for X-ray protective products of the Korean Industrial Standard. The experiment was conducted by increasing the shielding body one by one from the test condition of 60 kVp, 200 mA, 0.1sec and 100 kVp, 200 mA, 0.1 sec. At 60 kVp, 2 lead oxide-barium sulfate shields, 2 bismuth oxide 1.5 mm shields, and 5 bismuth oxide 0.3 mm shields showed shielding ability equal to or higher than that of lead 0.5 mm. At 100 kVp, 2 lead oxide-barium sulfate shields and 2 bismuth oxide 1.5 mm shields showed shielding ability equal to or higher than that of lead 0.5 mm. It was confirmed that when using 2 pieces of lead oxide-barium sulfate and 1.5 mm of bismuth oxide, respectively, it has shielding ability equivalent to that of lead. Bismuth oxide and lead oxide-barium sulfate are lightweight and have excellent shielding ability, thus they have excellent properties to be used as an apron for radiation protection or other shielding materials.
참고문헌 (20)
- Song SK, "Status of diagnostic X-ray equipment in the Republic of Korea, 2021", Public Health Weekly Report, 15(51), pp.3021~3032 (2022)
- 장동근, "감마선 에너지에 따른 납치마의 차폐효과 분석", 방사선기술과학, 37(4), pp.247~252 (2014), 대한방사선과학회
- Kwon YH, "A study of MSDs and their policy reform for workers in healthcare and medical fields", master, pp.2009
- Matsuda M, "Evaluation of lead aprons and their maintenance and management at our hospital", J Anesth, 30(3), pp.518~521 (2016)
- Park KY, "Modification of lipoproteins by blood lead(Pb)to result skin toxicity and pro-atherogenic effect", master, pp.2014
- Safety policy against lead poisoning, "Korea Industry Society Association", KISA, ~ (1995)
- 김선칠, "몬테카를로 시뮬레이션을 통한 바륨화합물의 의료방사선 차폐능 비교 분석", 한국방사선학회논문지, 7(6), pp.403~408 (2013), 한국방사선학회[DOI]
- 김선칠, "친환경 소재의 의료 방사선 차폐 시트 개발 ; Ⅰ: 섬유, 고무, 실리콘 소재 차폐 시트의 성능 비교평가", 방사선기술과학, 33(2), pp.121~126 (2010), 대한방사선과학회
- 박훈희, "PET", CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가, 2014, pp.37(1), 49~56[DOI]
- 장서구, "액상 실리콘과 금속화합물을 융합한 저선량 방사선 차폐 소재 개발을 위한 사전연구", 방사선기술과학, 40(3), pp.461~467 (2017), 대한방사선과학회[DOI]
- Korea Standard, "Testing method of lead equivalent for x-ray protective devices, No. 2015-0654. KS A 4025", ~ (2017)
- Ngaile JE, "Use of lead shields for radiation protection of superficial organs in patients undergoing head CT examinations", Radiation Protection Dosemetry, 130(4), pp.490~498 (2008)
- "Korean intellectual property office patent gazette(A), Radiation shielding fabric. Number 10-08600332;2008", ~ (2008)
- "Korean intellectual property office patent gazette(A), Radiation shielding fabric. Number 10-2009-0011082;2009", ~ (2009)
- 최태진, "의료영상용 방사선방호를 위한 무납차폐체 개발", 의학물리, 21(2), pp.232~237 (2010), 한국의학물리학회
- 박용순, "납 대체물질 차폐성능 비교평가", 공학기술논문지, 8(1), pp.79~85 (2015), 공학기술연구원[DOI]
- L HR, "Preparation and characterization of X-ray shielding materials by tungsten-silicon composites", master, pp.2014
- Trapp JV, "An introduction to radiation protection in medicine" (2008), Australasian Physical & Engineering Sciences in Medicine
- Jeong HW, "Broad beam transmission properties of some shielding materials for use in diagnostic radiology", Journal of Radiological Science and Technology, 27(4), pp.23~29 (2004)
- Structural shielding design and evaluation for medical use of X rays and gamma rays of energies up to 10 MeV, "National Council on Radiation Protection and Measurements(NCRP)", NCRP, ~ (1976)