본문 바로가기
KERD
논문KCI 등재

황산바륨을 이용한 친환경 X선 차폐체의 개발 및 성능평가

Development and Performance Evaluation of Eco-Friendly X-Ray Shields using BaSO4

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

At present, the most common substance used in radiation protection is lead. However,lead is a heavy metal that is harmful to the human body and causes environmental pollution. BaSO4 is an excellent material for X-Ray shielding because it has good X-Ray shielding abilityand it is cheap. In this study, we fabricated Gypsum-BaSO4 (G-B) shields with gypsum and BaSO4and Cement-BaSO4 (C-B) shields with cement and BaSO4 and conduct two tests (X-Ray shieldingtest, Strength test) to evaluate the performance of the shields. First of all, G-B, C-B Shields at 15mm thickness were fabricated to evaluate X-Ray shielding performance, including 1.0, 1.5 mmthickness lead and IKEN Board. To achieve X-Ray shielding capability of 1.5 mm lead at 100 kVX-Ray tube voltage, BaSO4 content 66% G-B shield and 68% C-B shield were required. Secondly,flexural strength test was conducted for G-B and C-B shields. Test results show that at the sameBaSO4 content, C-B shields were stronger than G-B shields. BaSO4 content 68% C-B shield was 3.5times stronger than 66% G-B shield.

Abstract

At present, the most common substance used in radiation protection is lead. However,lead is a heavy metal that is harmful to the human body and causes environmental pollution. BaSO4 is an excellent material for X-Ray shielding because it has good X-Ray shielding abilityand it is cheap. In this study, we fabricated Gypsum-BaSO4 (G-B) shields with gypsum and BaSO4and Cement-BaSO4 (C-B) shields with cement and BaSO4 and conduct two tests (X-Ray shieldingtest, Strength test) to evaluate the performance of the shields. First of all, G-B, C-B Shields at 15mm thickness were fabricated to evaluate X-Ray shielding performance, including 1.0, 1.5 mmthickness lead and IKEN Board. To achieve X-Ray shielding capability of 1.5 mm lead at 100 kVX-Ray tube voltage, BaSO4 content 66% G-B shield and 68% C-B shield were required. Secondly,flexural strength test was conducted for G-B and C-B shields. Test results show that at the sameBaSO4 content, C-B shields were stronger than G-B shields. BaSO4 content 68% C-B shield was 3.5times stronger than 66% G-B shield.

참고문헌 (15)

  1. 국내 납, 카드뮴 유통 및 배출현황 기초조사, "국립환경과학원", ~ (2011)
  2. 국토교통부, "X선 차폐공사, KS 41 70 06", ~ (2016)
  3. 김선칠, "몬테카를로 시뮬레이션을 통한 바륨화합물의 의료방사선 차폐능 비교 분석", 한국방사선학회논문지, 7(6), pp.403~408 (2013), 한국방사선학회[DOI]
  4. 김유현, "진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구", 의학물리, 16(1), pp.10~15 (2005), 한국의학물리학회
  5. 예신희, "리뷰 : 화재현장에서 노출될 수 있는 화학적 유해물질과 파킨슨병 간의 관련성", 생물정신의학, 24(1), pp.19~25 (2017), 대한생물정신의학회[DOI]
  6. 원자력안전위원회, "원자력안전위원회 고시 제2019-10호", ~ (2019)
  7. 이익진, "납 사업장내 토양오염에 관한 연구", 한국산업보건학회지, 14(3), pp.290~300 (2004), 한국산업보건학회
  8. 질병관리본부, "환자 촬영종류별 진단참고수준 마련: 치과촬영장치", ~ (2019)
  9. 한국산업표준, "진단용 X선 방사선에 대한 방어용구-제1부: 재료와 감쇠 특성 결정", KS C IEC 61331-1, ~ (2013)
  10. 한국산업표준, "섬유강화 시멘트판", KS L 5114, ~ (2014)
  11. ICRP, "Radiation and Your Patient: A Guide for medical Practitioners", ICRP committee 3, ~ (2001)
  12. Katoh Y, "Shielding Evaluation of Lead-free Boards for Diagnostic X-Rays", JSRT, 66, pp.1555~1560 (2010)
  13. 장태원, "Evaluation and management of lead exposure", Annals of Occupational and Environmental Medicine, 27(4), pp.1~9 (2015), 대한직업환경의학회[DOI]
  14. McCaffrey JP, "Radiation attenuation by lead and nonlead materials used in radiation shielding garments", Med. Phys, 34(2), pp.530~537 (2007)
  15. Western Australia Radiation Health Branch, "General shielding requirement for diagnostic X-Ray facilities", ~ (2004)

관련 논문AI추천

이 간행물의 다른 논문 (12건)