무릎 체중부하 촬영 보조장치 개발
Development of Knee Weight-bearing Radiography Assist Device
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The knee arthritis patients are generally performed standing position radiography. However, patients with pain caused by degenerative diseases or injuries in the knee have difficulty maintaining a standing position. Therefore, this study aims to develop a knee joint standing weight bearing projection assist device to solve these problems when patients undergo knee radiography due to various diseases. The design of the knee joint weight-bearing radiography assist device is carried out with 3D design and drawing production to secure basic data, electric support and frame manufacture. A fixed device for maintaining the patient's knee standing weight-bearing projection, an electric digital height device, a digital pro- tractor, and a safety device were designed. The arm support is made of PVC with a cushion to relieve the impact and make it easier to remove debris. The digital electric device can be moved up and down according to the patient's height, and a remote control is attached. The safety device is made to be adjustable in size by attaching metal hooks on both sides of the frame and to shield the scrotum. A digital protractor was attached to the side frame to set the desired knee angle. When a self-made assist device was used to perform a knee joint standing weight bearing projection, it help- ed maintain arm support and lower extremities position. In addition, the height could be adjusted using an assist device during standing projections, which helped the patient maintain the position.
Abstract
The knee arthritis patients are generally performed standing position radiography. However, patients with pain caused by degenerative diseases or injuries in the knee have difficulty maintaining a standing position. Therefore, this study aims to develop a knee joint standing weight bearing projection assist device to solve these problems when patients undergo knee radiography due to various diseases. The design of the knee joint weight-bearing radiography assist device is carried out with 3D design and drawing production to secure basic data, electric support and frame manufacture. A fixed device for maintaining the patient's knee standing weight-bearing projection, an electric digital height device, a digital pro- tractor, and a safety device were designed. The arm support is made of PVC with a cushion to relieve the impact and make it easier to remove debris. The digital electric device can be moved up and down according to the patient's height, and a remote control is attached. The safety device is made to be adjustable in size by attaching metal hooks on both sides of the frame and to shield the scrotum. A digital protractor was attached to the side frame to set the desired knee angle. When a self-made assist device was used to perform a knee joint standing weight bearing projection, it help- ed maintain arm support and lower extremities position. In addition, the height could be adjusted using an assist device during standing projections, which helped the patient maintain the position.
참고문헌 (15)
- Manlapaz DG, "Risk factors for falls in adults with knee osteoarthritis : A systematic review", Pm&r, 11(7), pp.745~757 (2019)[DOI]
- Leach RE, "Weight-bearing radiography in osteoarthritis of the knee", Radiology, 97(2), pp.265~268 (1970)[DOI]
- Seo SY, "The evaluation of usefulness for new assistant device to observe posterior cruciate ligament rupture and patellofemoral joint injury in emergency patient", Journal of Radiological Science and Technology, 33(2), pp.93~96 (2010)[DOI]
- 공창기, "Rosenberg View 검사를 위한 보조기구의 유용성 평가", 한국방사선학회논문지, 14(2), pp.129~138 (2020), 한국방사선학회[DOI]
- Yoo JH, "The prone kneeling view of the intercondylar notch for radiographic assessment of the femoral tunnel position in anterior cruciate ligament reconstruction", Arthroscopy : The Journal of Arthroscopic & Related Surgery, 24(4), pp.465~471 (2008)[DOI]
- Mars Group, "Radiographic findings in revision anterior cruciate ligament reconstructions from the MARS cohort", The Journal of Knee Surgery, pp.239~248 (2013)[DOI]
- Anderson AF, "Radiographic measurements of the intercondylar notch. Are they accurate?", Arthroscopy:The Journal of Arthroscopic & Related Surgery, 23(3), pp.261~268 (2007)[DOI]
- Cole J, "Radiographic analysis of femoral tunnel position in anterior cruciate ligament reconstruction", The American Journal of Knee Surgery, 13(4), pp.218~222 (2000)[DOI]
- Hobbs DL, "Osteoarthritis and the rosenberg method", Radiological Technology, 77(3), pp.179~182 (2006)[DOI]
- Vignon E, "Measurement of radiographic joint space width in the tibiofemoral compartment of the osteoarthritic knee : Comparison of standing anteroposterior and Lyon schuss views", Arthritis Rheum, 48(2), pp.378~384 (2003)[DOI]
- Tipton SC, "Using the anatomical axis as an alternative to the mechanical axis to assess knee alignment", Orthopedics, 38(12), pp.e1115~e1120 (2015)[DOI]
- Kappel A, "Reliability of stress radiography in the assessment of coronal laxity following total knee arthroplasty", Knee, 27(1), pp.221~228 (2019)[DOI]
- Hashemi J, "The geometry of the tibial plateau and its influence on the biomechanics of the tibiofemoral joint", J Bone Joint Surg Am, 90(12), pp.2724~2734 (2008)[DOI]
- Oosthuizen CR, "The knee osteoarthritis grading system for arthroplasty", J Arthroplasty, 34(3), pp.450~455 (2019)[DOI]
- Rosenberg TD, "The forty-five-degree posteroanterior flexion weight-bearing radiograph of the knee", J Bone Joint Surg Am, 70(10), pp.1479~1483 (1988)[DOI]