This study aimed to found out the effect of patellofemoral overlap distance by changing femur thickness and center X-ray angles in Merchant method images. Based on the femur thickness, it suggested tube angle minimizes overlap. It was conducted by Merchant method, a knee tangential view, and the image was obtained by changing the thigh thickness from 14 to 20 ㎝ and the center ray angle from 60°, 57°, 55°. The images were measured by five researchers using a method of measuring the overlap, which was designed by them. The results showed at 60°, 57°, 55° angle, the patellofemoral overlap distance resulted in 0.47±0.66 to 20.89±0.65 ㎝, 2.26±0.28 to 15.73±0.62 ㎝, 1.39 ± 0.83 to 12.49 ± 0.37 ㎝. However, for 57° and 55°, no overlap in thickness under 14.5 and 14 to 15.5 didn't appear. it showed high correlation between femur thickness and overlap. The difference in the mean value of overlap in each group showed a statistically significant difference (p<0.01), all were classified as independent groups in the post-hoc test. In all images, the patellofemoral overlap distance increased as the thickness increased, and at the average thickness of Korean men and women, overlap decreased when reducing center ray. When conducting Merchant tests on Koreans, it was suggested it would be useful to use 57° angle because it minimize the effects of overlap and intrusions of tibia.

Abstract

This study aimed to found out the effect of patellofemoral overlap distance by changing femur thickness and center X-ray angles in Merchant method images. Based on the femur thickness, it suggested tube angle minimizes overlap. It was conducted by Merchant method, a knee tangential view, and the image was obtained by changing the thigh thickness from 14 to 20 ㎝ and the center ray angle from 60°, 57°, 55°. The images were measured by five researchers using a method of measuring the overlap, which was designed by them. The results showed at 60°, 57°, 55° angle, the patellofemoral overlap distance resulted in 0.47±0.66 to 20.89±0.65 ㎝, 2.26±0.28 to 15.73±0.62 ㎝, 1.39 ± 0.83 to 12.49 ± 0.37 ㎝. However, for 57° and 55°, no overlap in thickness under 14.5 and 14 to 15.5 didn't appear. it showed high correlation between femur thickness and overlap. The difference in the mean value of overlap in each group showed a statistically significant difference (p<0.01), all were classified as independent groups in the post-hoc test. In all images, the patellofemoral overlap distance increased as the thickness increased, and at the average thickness of Korean men and women, overlap decreased when reducing center ray. When conducting Merchant tests on Koreans, it was suggested it would be useful to use 57° angle because it minimize the effects of overlap and intrusions of tibia.

참고문헌 (18)

  1. The Korean Orthopedic Association, , Orthopedics, 6(2), pp.686~694 (1995)
  2. DeHaven KE, "Chondromalacia patellae in athletes. Clinical presentation and conservative management", Am J Sports Med, 7, pp.5~11 (1979)
  3. Hughston JCL, "Subluxation of the patella", J Bone Joint Surg, 50A, pp.1003~ (1968)
  4. Greenspan A, "Musculoskeletal orthopedic imaging : A practical approach", Garvey Medicine, 4, pp.243~248 (2008)
  5. Merchant AC, "Roentgenographic analysis of patellofemoral congruence", J. Bone Joint Surg., 56A, pp.1391~ (1974)
  6. Mc Alindon T, "Determinanats of disability in osteoarthritis of the knee", Annals of the Rheumatic Diseases, 52(4), pp.258~262 (1993)
  7. Settegast, "Typische roentgenbilder von normalen menschen", Lehmans Med Atlanten, 5, pp.211~223 (1921)
  8. Ficat RP, "Disorder of the patellofemoral joint" (1977), Williams & Wilkins
  9. 서선열, "응급환자에서 후방십자인대 손상 및 슬대퇴 관절을 관찰하기 위한 보조기구 제작 및 유용성 평가", 방사선기술과학, 33(2), pp.93~96 (2010), 대한방사선과학회
  10. Keats TE, "Atlas of Radiologic Measurement:Lower Extermity", pp.268~271 (2001)
  11. "South Korea Human Body Index" (2019)[URL]
  12. Martinew S, "Diagnosis of patellofemoral malalignment by computed tomography", J Comput Assist Tomogr, 7, pp.1050~1053 (1983)
  13. Dupuy DE, "Kinematic CT of the patellofemoral joint", AJR Am J Roentgenol, 169, pp.211~215 (1997)
  14. Shellok FG, "Patellar tracking abnormalitites: Clinical experience with kinematic MR imaging in 130 patients", Radiology, 172, pp.799~804 (1989)
  15. Brossmann J, "Patellar tracking patterns during active and passive knee extension: Evaluation with motion-triggered cine MR imaging", Radiology, 187, pp.205~212 (1993)
  16. Chung YK, "A clinical study of traumatic dislocation of the knee joint : Analysis of 7 cases", Journal of the Korean Orthopaedic Association, 21(4), pp.703~708 (1986)
  17. 김현진, "슬대퇴관절의 Merchant View에서 중심 X선 위치에 따른 일치각 평가", 방사선기술과학, 42(6), pp.423~428 (2019), 대한방사선과학회
  18. Aglietti P, "Patellar pain and incongruence. I: Measurements of incongruence", Clinical Orthopaedics and Related Research, 176, pp.217~224 (1983)

관련 논문AI추천