Comparative Evaluation of Filters for Speckle Noise Reduction in a Clinical Liver Ultrasound Image
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This study aimed to compare filters for reducing speckle noise in ultrasound images using clinical liver images. We acquired the clinical liver ultrasound images, and noisy images were obtained by adding 0.01, 0.05, 0.10, and 0.50 intensity levels of speckle noise to the liver images. The Wiener filter, median modified Wiener filter, gamma filter, and Lee filter were designed for the noisy images by setting window sizes at 3×3, 5×5, and 7×7. The coefficient of variation (COV) and contrast to noise ratio (CNR) were calculated to evaluate noise reduction and various filters. Moreover, the fil- ter with the highest image quality was selected and quantitatively compared to a noisy image. As a result, COV and CNR showed the noise improved result when the Lee filter was applied. Furthermore, the Lee filter image with a window size of 7×7 was noted to possess approximately a minimum of 1.28 to a maximum of 3.38 times better COV and a minimum of 2.18 to a maximum of 5.50 times better CNR than the noisy image. In conclusion, we confirmed that the Lee filter was effective in reducing speckle noise and proved that an appropriate window size needs to be set considering blurring.
Abstract
This study aimed to compare filters for reducing speckle noise in ultrasound images using clinical liver images. We acquired the clinical liver ultrasound images, and noisy images were obtained by adding 0.01, 0.05, 0.10, and 0.50 intensity levels of speckle noise to the liver images. The Wiener filter, median modified Wiener filter, gamma filter, and Lee filter were designed for the noisy images by setting window sizes at 3×3, 5×5, and 7×7. The coefficient of variation (COV) and contrast to noise ratio (CNR) were calculated to evaluate noise reduction and various filters. Moreover, the fil- ter with the highest image quality was selected and quantitatively compared to a noisy image. As a result, COV and CNR showed the noise improved result when the Lee filter was applied. Furthermore, the Lee filter image with a window size of 7×7 was noted to possess approximately a minimum of 1.28 to a maximum of 3.38 times better COV and a minimum of 2.18 to a maximum of 5.50 times better CNR than the noisy image. In conclusion, we confirmed that the Lee filter was effective in reducing speckle noise and proved that an appropriate window size needs to be set considering blurring.
참고문헌 (40)
- "The top 10 causes of death"[URL]
- "Causes of death statistics in 2019"[URL]
- Brancatelli G, "Fibropolycystic liver disease : CT and MR imaging findings", RadioGraphics, 25(3), pp.659~670 (2005)[DOI]
- Boll DT, "Diffuse liver disease : Strategies for hepatic CT and MR imaging", RadioGraphics, 29(6), pp.1591~1614 (2009)[DOI]
- Ballestri S, "Role of ultrasound in the diagnosis and treatment of nonalcoholic fatty liver disease and its complications. Expert Rev. Gastroenterol", Hepatol, 9(5), pp.603~627 (2015)[DOI]
- Gerstenmaier JF, "Ultrasound in chronic liver disease", Insights Imaging, 5, pp.441~455 (2014)[DOI]
- Goyal N, "qNon-invasive evaluation of liver cirrhosis using ultrasound", Clin. Radiol, 64(11), pp.1056~1066 (2009)[DOI]
- Solbiati L, "Guidance and monitoring of radiofrequency liver tumor ablation with contrast-enhanced ultrasound", Eur. J. Radiol, 51, pp.S19~S23 (2004)[DOI]
- Lupşor-Platon ML, "Noninvasive assessment of liver steatosis using ultrasound methods", Med. Ultrason, 16(3), pp.236~245 (2014)[DOI]
- Schwenzer NF, "Non-invasive assessment and quantification of liver steatosis by ultrasound, computed tomography and magnetic resonance", J. Hepatol, 51(3), pp.433~445 (2009)[DOI]
- Acharya UR, "Automated characterization of fatty liver disease and cirrhosis using curvelet transform and entropy features extracted from ultrasound images", Comput. Biol. Med, 79, pp.250~258 (2016)[DOI]
- Nicolau C, "Sonographic diagnosis and hemodynamic correlation in veno-occlusive disease of the liver", J. Ultrasound Med, 12(8), pp.437~440 (1993)[DOI]
- Sagi R, "Nonalcoholic fatty liver disease in overweight children and adolescents", Acta Paediatr, 96(8), pp.1209~1213 (2007)[DOI]
- Amitrano L, "Risk factors and clinical presentation of portal vein thrombosis in patients with liver cirrhosis", J. Hepatol, 40(5), pp.736~741 (2004)[DOI]
- Mwanza T, "Ultrasonography and angiographic examination of normal canine liver vessels", Jpn. J. Vet. Res, 44(3), pp.179~188 (1996)[DOI]
- Zhou, JH, "Haemodynamic parameters of the hepatic artery and vein can detect liver metastases:Assessment using contrast-enhanced ultrasound", Br. J. Radiol, 81(962), pp.113~119 (2008)[DOI]
- Marzouni HZ, "Diagnostic value of hepatic vein ultrasound in early detection of liver cirrhosis", Galen Med. J, 7, pp.e1140~ (2018)
- Jeyalakshmi TR, "A modified method for speckle noise removal in ultrasound medical images", Int. J. Comput. Electr. Eng, 2(1), pp.54~ (2010)
- Karthikeyan K, "Speckle noise reduction of medical ultrasound images using bayesshrink wavelet threshold", Int. J. Comput. Appl, 22(9), pp.8~14 (2011)[DOI]
- Krissian K, "Speckle-constrained of ultrasound images", 2005IEEE Computer Society Conference on Computer Vision and Pattern Recognition(CVPR' '05), 2, pp.547~552 (2005)
- Singh K, "A hybrid algorithm for speckle noise reduction of ultrasound images", Comput. Method. Programs Biomed, 148, pp.55~69 (2017)[DOI]
- Outtas M, "Speckle noise reduction in ultrasound image based on A Multiplicative Multiresolution Decomposition (MMD)", Eighth ed. of Int. Symp. On Sugnal, Image, Video and Communications (2014)
- Leal AS, "A new wavelet family for speckle noise reduction in medical ultrasound images", Measurement, 140, pp.572~581 (2019)[DOI]
- Podilchuk C, "Speckle reduction using stepped-frequency continuous wave ultrasound", 2012 IEEE Signal Processing in Medicine and Biology Symposium(SPMB), pp.1~4 (2012)
- Lopes A, "Adaptive speckle filters and scene heterogeneity", IEEE Trans. Geosci. Remote Sensing, 28(6), pp.992~1000 (1990)[DOI]
- Sudha S, "Speckle noise reduction in ultrasound images by wavelet thresholding based on weighted variance", Int. J. Comput. Theor. Eng, 1(1), pp.7~ (2009)
- Cannistraci CV, "Median modified wiener filter for nonlinear adaptive spatial denoising of protein NMR multidimensional spectra", Sci. Rep, 5(1), pp.8017~ (2015)[DOI]
- 박찬록, "Median modified wiener filter for improving the image quality of gamma camera images", Nuclear Engineering and Technology, 52(10), pp.2328~2333 (2020), 한국원자력학회[DOI]
- Lee JS, "Digital image enhancement and noise filtering by use of local statistics", IEEE Trans. Pattern Anal. Mach. Intell, 2, pp.165~168 (1980)[DOI]
- Chen J, "New insights into the noise reduction Wiener filter", IEEE Trans. Aud. Speech Lang. Process, 14(4), pp.1218~1234 (2006)[DOI]
- Rodriguez-Molares A, "The generalized contrast-to-noise ratio: A formal definition for lesion detectability", IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 67(4), pp.745~759 (2019)[DOI]
- 조진영, "초음파검사에서 비알콜성 지방간과 국소지방회피영역에 대한 GLCM Algorithm 영상분석", 방사선기술과학, 40(2), pp.205~211 (2017), 대한방사선과학회[DOI]
- 김도형, "초음파팬텀(ATS-539)을 이용한 의료용 초음파장비의 성능검사(대구지역을 중심으로)", 방사선기술과학, 37(4), pp.295~305 (2014), 대한방사선과학회
- Khan MN, "Experimental evaluation of filters used for removing speckle noise and enhancing ultrasound image quality", Biomed. Signal Process. Control, 73, pp.103399~ (2022)[DOI]
- Jabarulla MY, "Speckle reduction in ultrasound liver image based on sparse representation over a learned dictionary", Applied Sciences, 8(6), pp.903~ (2018)[DOI]
- Ramamoorthy S, "An efficient method for speckle noise reduction in ultrasound liver images for e-health applications", Distributed Computing and Internet Technology:10th International Conference, pp.311~321 (2014), ICDCIT
- Pregitha RE, "Speckle noise reduction in ultrasound fetal images using edge preserving adaptive shock filters", Int. J. Sci. Res. Publ, 2(3), pp.1~3 (2012)
- Islam MA, "Speckle noise reduction from ultrasound image using modified binning method and fuzzy inference system", 20132nd International Conference on Advances in Electrical Engineering(ICAEE), pp.359~362 (2013)
- Loupas T, "Noise reduction in ultrasonic images by digital filtering", Br. J. Radiol, 60(712), pp.389~392 (1987)[DOI]
- Gupta S, "Dealing with noise problem in machine learning data-sets: A systematic review", Procedia Comput. Sci, 161, pp.466~474 (2019)[DOI]