본문 바로가기
KERD
논문KCI 등재

직류전기장이 인가된 상태에서 쌍둥이 전선을 통해 전파하는 화염들에 대한 상호작용

Interaction of Flame Spread Over Twin Electrical Wires with Applied DC Electric Fields

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

The effect of a direct current (DC) electric field on the characteristics of flame spread over polyethylene (PE) -insulated twin electrical wires was studied by varying wire gap (S) and voltage (VDC). The flame spread rate (FSR) for the wire with negative voltage (SF-) was larger than with positive voltage (SF+) initially and becomes the same in developed region. The FSR could be classified into two regimes; twin flame spread and single flame spread after the extinction of positive voltage (SF+). In each regime, three sub-regimes are identified depending on S and VDC. In each regime, FSR could be characterized by S and VDC The variation of FSR was explained by thermal balance mechanism with ionic wind effect. In high intensive of voltage, the flames were extinguished, at excessive voltages, an electrical short occurred.

Abstract

The effect of a direct current (DC) electric field on the characteristics of flame spread over polyethylene (PE) -insulated twin electrical wires was studied by varying wire gap (S) and voltage (VDC). The flame spread rate (FSR) for the wire with negative voltage (SF-) was larger than with positive voltage (SF+) initially and becomes the same in developed region. The FSR could be classified into two regimes; twin flame spread and single flame spread after the extinction of positive voltage (SF+). In each regime, three sub-regimes are identified depending on S and VDC. In each regime, FSR could be characterized by S and VDC The variation of FSR was explained by thermal balance mechanism with ionic wind effect. In high intensive of voltage, the flames were extinguished, at excessive voltages, an electrical short occurred.

참고문헌 (14)

  1. O. Fujita, "Effect of Low External Flow on Flame Spread over Polyethylene-Insulated Wire in Microgravity", Proceedings of the Combustion Institute, 29, pp.2545~2552 (2002)[DOI]
  2. M. Kikuchi, "Experimental Study on Flame Spread over Wire Insulation in Microgravity", Proceedings of the Combustion Institute, 26, pp.2507~2514 (1998)
  3. Y. Nakamura, "Flame Spread over Electrical in Sub-Atmospheric Pressure", Proceedings of the Combustion Institute, 32, pp.2559~2566 (2009)[DOI]
  4. Y. Nakamura, "Opposed-Wind Effect on Flame Spread of Electric Wire in Sub-Atmospheric Pressure", J. Therm. Sci. Tech., 3, pp.430~441 (2008)[DOI]
  5. A. Umemura, "Physical Model Analysis of Flame Spreading along an Electrical Wire in Microgravity", Proceedings of the Combustion Institute, 29, pp.2535~2543 (2002)[DOI]
  6. S. Takahashi, "Study on Unsteady Molten Insulation Volume Change during Flame Spreading over Wire Insulation", Proceedings of the Combustion Institute, 34, pp.2657~2664 (2013)[DOI]
  7. Y. Nakamura, "Flame Spread over Polymer-Insulated Wire in Sub-Atmospheric Pressure : Similarity to Microgravity Phenomena", Prog. scale modeling, pp.17~27 (2008)
  8. X. Huang, "Ignition-to-Spread Transition of Externally Heated Electrical Wire", Proceedings of the Combustion Institute, 34, pp.2505~2512 (2013)[DOI]
  9. Advanced Spacecraft Fire Safety: Proposed Projects and Program Plan, NASA-CR-185147, "W.W Youngblood", NASA, ~ (1989)
  10. M.K. Kim, "Effect of AC Electric Fields on Spread Rate over Electrical Wire", Proceedings of the Combustion Institute, 33, pp.1145~1115 (2011)[DOI]
  11. S.J. Lim, "Flame Spread over Electrical Wire with AC Electric Fields: Internal Circulation, Fuel Vapor-Jet, Spread Rate Acceleration, and Molten Insulator Dripping", Combust. Flame, 162(4), pp.1167~1175 (2015)[DOI]
  12. 임승재, "교류전기장이 인가된 폴리에틸렌으로 피복된 기울어진 전선을 통해 하향으로 전파하는 화염에 대한 실험적 연구", 한국연소학회지, 19(4), pp.1~7 (2014), 한국연소학회[DOI]
  13. 박순호, "교류전기장이 인가된 상태에서 전선을 통해 전파하는 화염에 대한 전선직경의 영향", 한국연소학회지, 22(3), pp.1~7 (2017), 한국연소학회[DOI]
  14. S.J. Lim, "Flame Spread over Inclined Electrical Wires with AC Electric Fields", Combust. Flame, 185, pp.82~92 (2017)[DOI]

관련 논문AI추천