AC 전기장이 인가된 구리 전선을 통해 전파하는 화염에 대해 피복재의 두께에 따른 화염 거동에 대한 실험적 연구

Effects of Insulation Thickness on Flame Spread over Electrical Copper Wire with Applied AC Electric Fields

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Effects of insulation thickness on flame spread over electrical copper wires with applied AC electric fields were experimentally investigated. The AC volrage and frequency varied in ranges of 0-5 kV and 10-1000 Hz, respectively. A one electrode configuration was used such that the electric potential was applied to one wire end and thus the infinite ambience could be a ground. The results showed that the flame shape and the tilting direction were significantly influnced by applied voltage and frequency. The flame spread rate decreased in an increase of insulation thickness as well as varied sensitively with applied votage and frequency. Additionally, the molten polyethylene (PE) experienced various dynamic behaviors such as dripping of molten PE, electrospray, di-electro-phoresis, and rotation of molten PE, essentially affecting the flame spread rate. These complicated phenomena were systematically analyzed and discussed.

Abstract

Effects of insulation thickness on flame spread over electrical copper wires with applied AC electric fields were experimentally investigated. The AC volrage and frequency varied in ranges of 0-5 kV and 10-1000 Hz, respectively. A one electrode configuration was used such that the electric potential was applied to one wire end and thus the infinite ambience could be a ground. The results showed that the flame shape and the tilting direction were significantly influnced by applied voltage and frequency. The flame spread rate decreased in an increase of insulation thickness as well as varied sensitively with applied votage and frequency. Additionally, the molten polyethylene (PE) experienced various dynamic behaviors such as dripping of molten PE, electrospray, di-electro-phoresis, and rotation of molten PE, essentially affecting the flame spread rate. These complicated phenomena were systematically analyzed and discussed.

참고문헌 (15)

  1. O. Fujita, "Effect of low external flow on flame spread over polyethyleneinsulated wire in microgravity", Proc. Combuts. Inst, 29, pp.2545~2552 (2002)
  2. M. Kikuchi, "Experimental study on flame spread over wire insulation in microgravity", Proc. Combust. Inst, 26, pp.2507~2514 (1998)
  3. Y. Nakamura, "Flame spread over electrical in subatmospheric pressure", Proc. Combuts. Inst, 32, pp.2559~2566 (2009)
  4. Y. Nakamura, "Opposed-wind effect on flame spread of electric wire in sub-atmospheric pressure", Journal of thermal science and technology, 3, pp.430~441 (2008)
  5. A. Umemura, "Phisical model analysis of flame spreading along an electrical wire in microgravity", Proc. Combuts. Inst, 29, pp.2535~2543 (2002)
  6. S. Takahashi, "Study on unsteady molten insulation volume change during flame spreading over wire insulation", Proc. Combuts. Inst, 34, pp.2657~2664 (2013)
  7. Y. Nakamura, "Flame spread over polymer-insulated wire in sub-atmospheric pressure : Similarity to microgravity phenomena", Progress in scale modeling, pp.17~27 (2008)
  8. X. Huang, "Ignitiontospread transition of externally heated electrical wire", Proc. Combuts. Inst, 34, pp.2505~2512 (2013)
  9. NASA Contractor Report 185147, "W.W Youngblood", ~ (1989)
  10. M. K. Kim, "Effect of AC electric fields on spread rate over electrical wire", Proc. Combust. Inst, 33, pp.1145~1115 (2011)
  11. S. J. Lim, "Flame spread over electrical wire with AC electric fields: Internal circulation, fuel vapor-jet, spread rate acceleration, and molten insulator dripping", Combust. Flame, 162(4), pp.1167~1175 (2015)
  12. 임승재, "교류전기장이 인가된 폴리에틸렌으로 피복된 기울어진 전선을 통해 하향으로 전파하는 화염에 대한 실험적 연구", 한국연소학회지, 19(4), pp.1~7 (2014), 한국연소학회[DOI]
  13. "Finite Element Method Magnetics v-4. 2"[URL]
  14. S. H. Park, "Effect of AC electric field on flame spread in electrical wire : Variation in polyethylene insulation thickness and di-electrophoresis phenomenon", Combust. Flame, 202, pp.107~118 (2019)
  15. S. H. Park, "Flame spread over twin electrical wires with applied DC electric fields", Combust. Flame, 210, pp.350~359 (2019)