초록

An experimental study on spreading flame over electrical wire, which was insulated by Polyethylene(PE) and had different diameters, was conducted with applied AC electric field. The result showed that the flame spread rate decreased in increase of the diameter of insulator at a fixed electric field. The flame spread rate exhibited increase or decrease tendency with applied AC electric field, having three distinct regimes depending on applied voltage and frequency. In each regime, the flame spread rate was characterized by physical parameters of applied electric fields and wire dimensions, and the behaviors could be explained by a thermal balance mechanism.

Abstract

An experimental study on spreading flame over electrical wire, which was insulated by Polyethylene(PE) and had different diameters, was conducted with applied AC electric field. The result showed that the flame spread rate decreased in increase of the diameter of insulator at a fixed electric field. The flame spread rate exhibited increase or decrease tendency with applied AC electric field, having three distinct regimes depending on applied voltage and frequency. In each regime, the flame spread rate was characterized by physical parameters of applied electric fields and wire dimensions, and the behaviors could be explained by a thermal balance mechanism.

참고문헌 (13)

  1. O. Fujita, "Effect of low external flow on flame spread over polyethyleneinsulated wire in microgravity", Proc. Combuts. Inst., 29, pp.2545~2552 (2002)
  2. M. Kikuchi, "Experimental study on flame spread over wire insulation in microgravity", Proc. Combust. Inst., 26, pp.2507~2514 (1998)
  3. Y. Nakamura, "Flame spread over electrical in subatmospheric pressure", Proc. Combuts. Inst., 32, pp.2559~2566 (2009)
  4. Y. Nakamura, "Opposed-wind effect on flame spread of electric wire in sub-atmospheric pressure", J Therm. Sci. Technol, 3, pp.430~441 (2008)
  5. A. Umemura, "Phisical model analysis of flame spreading along an electrical wire in microgravity", Proc. Combuts. Inst., 29, pp.2535~2543 (2002)
  6. S. Takahashi, "Study on unsteady molten insulation volume change during flame spreading over wire insulation", Proc. Combuts. Inst., 34, pp.2657~2664 (2013)
  7. Y. Nakamura, "Flame spread over polymer-insulated wire in sub-atmospheric pressure : Similarity to microgravity phenomena", Progress in scale modeling, pp.17~27 (2008)
  8. X. Huang, "Ignitionto-spread transition of externally heated electrical wire", Proc. Combuts. Inst., 34, pp.2505~2512 (2013)
  9. NASA Contractor Report 185147, "W.W Youngblood", ~ (1989)
  10. M. K. Kim, "Effect of AC electric fields on spread rate over electrical wire", Proc. Combust. Inst, 33, pp.1145~1115 (2011)
  11. S. J. Lim, "Flame spread over electrical wire with AC electric fields: Internal circulation, fuel vapor-jet, spread rate acceleration, and molten insulator dripping", Combust. Flame, 162(4), pp.1167~1175 (2015)
  12. 임승재, "교류전기장이 인가된 폴리에틸렌으로 피복된 기울어진 전선을 통해 하향으로 전파하는 화염에 대한 실험적 연구", 한국연소학회지, 19(4), pp.1~7 (2014), 한국연소학회[DOI]
  13. "Finite Element Method Magnetics v-4. 2"[URL]

관련 논문AI추천

교류전기장이 인가된 폴리에틸렌으로 피복된 기울어진 전선을 통해 하향으로 전파하는 화염에 대한 실험적 연구박정, 김민국, 임승재, 정석호, Osamu Fujita한국연소학회 · 한국연소학회지2014 · 제19권 제4호AC 전기장이 인가된 구리 전선을 통해 전파하는 화염에 대해 피복재의 두께에 따른 화염 거동에 대한 실험적 연구박정, 강민성, 권오붕, 유춘상, 정석호한국연소학회 · 한국연소학회지2020 · 제25권 제4호직류전기장이 인가된 상태에서 쌍둥이 전선을 통해 전파하는 화염들에 대한 상호작용박정, 권오붕, 김희준, 박순호, 정석호한국연소학회 · 한국연소학회지2018 · 제23권 제2호층류 부상 화염의 화염부상 높이 감소 구간에서 교류 전기장이 인가된 화염에 관한 영향박정, 길상인, 김경택, 반규호, 서보현, 정석호한국연소학회 · 한국연소학회지2017 · 제22권 제3호직류 전기장을 인가한 층류부착화염에서 물질-열 확산 및 부력에 의한 화염진동 비교에 관한 연구박정, 길상인, 김영주, 서상일, 윤성환, 윤진한, 한종규한국연소학회 · 한국연소학회지2011 · 제16권 제3호직류전기장이 인가된 층류제트화염에서 물질-열 확산과 부력에 의한 진동비교에 관한 연구박정, 권오붕, 김태현, 박종호, 윤성환, 한종규한국연소학회 · 한국연소학회지2012 · 제17권 제1호