유한요소 기법을 활용한 설계검증 및 4M 변경점 관리를 통한 레이더장비 품질 신뢰성 확보에 관한 연구

A Study on the Design Verification by Using Finite Elements Method and Quality Improvement of Radar by Managing Change Points of 4M

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류학제간연구

초록

Purpose: The purpose of this study is to improve the quality of the PGM system by improving the structure and production process of slip-ring rotary joint for radar. Methods: The improvement measures for each cause are established th rough failure analysis of broken items. Specifically, changing in the housing to improve the heating system. Changing the transportation method to prevent damage to equipment during transport. Changing work process of the attenuator ring to prevent damage. etc. Results: The results of this study are as follows; improving the heating system reduces heat generated by the attenuator by about 7 degrees and obtain additional temperature margins. Reduction of defect rate because of adding X-band rotary joint run-out measurement test, ESS of slip-ring rotary joint and Transportation improvement(reinforced flight boxes, tube protection, etc). Getting stable VSWR values by improving work process of attenuator overheating due to a bad bonding process. Conclusion: Through this study, improvements were made to slip-ring rotary joint that failed repeatedly for various reasons. As a result of the application of the improvements, the same fault does not occur until now, so we can see that the quality of PGM has improved.

Abstract

Purpose: The purpose of this study is to improve the quality of the PGM system by improving the structure and production process of slip-ring rotary joint for radar. Methods: The improvement measures for each cause are established th rough failure analysis of broken items. Specifically, changing in the housing to improve the heating system. Changing the transportation method to prevent damage to equipment during transport. Changing work process of the attenuator ring to prevent damage. etc. Results: The results of this study are as follows; improving the heating system reduces heat generated by the attenuator by about 7 degrees and obtain additional temperature margins. Reduction of defect rate because of adding X-band rotary joint run-out measurement test, ESS of slip-ring rotary joint and Transportation improvement(reinforced flight boxes, tube protection, etc). Getting stable VSWR values by improving work process of attenuator overheating due to a bad bonding process. Conclusion: Through this study, improvements were made to slip-ring rotary joint that failed repeatedly for various reasons. As a result of the application of the improvements, the same fault does not occur until now, so we can see that the quality of PGM has improved.

참고문헌 (11)

  1. 최상민, "LST-II급 함정 함수 LCM 거치대 손상에 대한 개선방안 연구", 품질경영학회지, 47(1), pp.139~150 (2019), 한국품질경영학회[DOI]
  2. 엄상철, "2축 X-band 안테나 지향 기구장치의 개발과 검증", 한국항공우주학회지, 46(5), pp.410~418 (2018), 한국항공우주학회
  3. 정영권, "신뢰성 기반의 국방 품질정책 전환을 위한 방안 연구", 품질경영학회지, 46(2), pp.193~210 (2018), 한국품질경영학회[DOI]
  4. 조희진, "레이더장비에 적용되는 저압전력계통의 서지보호장치 기능개선에 관한 연구", 한국산학기술학회논문지, 17(6), pp.400~407 (2016), 한국산학기술학회[DOI]
  5. 조희진, "레이더장비에 적용되는 통신 IC 소비전력 개선을 통한 회로카드조립체 품질 향상에 관한 연구", 한국산학기술학회논문지, 19(12), pp.1~6 (2018), 한국산학기술학회[DOI]
  6. Kang. S. R., "Three-Dimensional Phase Array Antenna for K-MASM Multi Function Radar", The Proceedings of the Korea Electromagnetic Engineering Society, 28(2), pp.20~22 (2017)
  7. 2-Channel Rotary Joint design for improved Phase Noise, "Kim. H. T.", Korean Society for Precision Engineering, 339~340 (2017)
  8. 박진원, "한국형 전술차량 후방밴 강성·강도 보강을 통한 내구성 향상에 관한 연구", 품질경영학회지, 46(2), pp.269~282 (2018), 한국품질경영학회[DOI]
  9. 서상원, "해외 선진국 규정 분석을 통한 국내 정부품질보증 효율성 향상 방안", 품질경영학회지, 45(3), pp.335~348 (2017), 한국품질경영학회[DOI]
  10. 송성찬, "밀리미터파(Ka 밴드) 복합모드 탐색기용 고출력 펄스형 진행파관 증폭기(TWTA) 설계 및 제작", 한국전자파학회 논문지, 30(4), pp.307~313 (2019), 한국전자파학회[DOI]
  11. 송성찬, "낮은 정재파비와 삽입손실을 갖는 밀리미터파(Ka 밴드) 복합모드 탐색기용 2-축 도파관 로터리 조인트 설계 및 제작", 한국전자파학회 논문지, 30(2), pp.173~176 (2019), 한국전자파학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (17건)