도시철도 지하터널용 전기집진기 개발을 위한 집진극 형상에 대한 기초연구
A Study on Collecting Electrode Design for Developing Electrostatic Precipitator(ESP) of Urban Railway Underground Tunnels
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this study, the characteristics of turbulent flow and collection efficiency for an one-stage electrostatic precipitator(ESP) with slit type collecting electrode for urban railway underground tunnels were obtained using computational fluid dynamics(CFD) commercial code FLUENT 6.3 and lab-scale experiments. The electrostatic precipitator was operated under high gas velocity(3~12m/s). Five different designs of collecting electrode, flat plate-type and a slit-type of 3mm, 5mm, 7mm and 10mm slit width and four various gas velocity(3, 6, 9, and 12m/s) were used and applied. A standard k-ℇ model in CFD commercial code FLUENT 6.3 was used for flow simulation. The flow simulation results showed that the turbulent intensity of flat plate-type was higher than slit-type under all gas velocity conditions and also the turbulent intensity of flat plate-type was increased continuously, but in case of slit-type was maintained at constant range. And, the turbulent intensity was decreased according to increasing of slit width. The experimental results showed that the collection efficiency of slit-type was higher than flat plate-type under all gas velocity conditions. And, over 6m/s gas velocity condition, the collection efficiency of 5mm and 7mm was highest, when compared to 3mm and 10mm.
Abstract
In this study, the characteristics of turbulent flow and collection efficiency for an one-stage electrostatic precipitator(ESP) with slit type collecting electrode for urban railway underground tunnels were obtained using computational fluid dynamics(CFD) commercial code FLUENT 6.3 and lab-scale experiments. The electrostatic precipitator was operated under high gas velocity(3~12m/s). Five different designs of collecting electrode, flat plate-type and a slit-type of 3mm, 5mm, 7mm and 10mm slit width and four various gas velocity(3, 6, 9, and 12m/s) were used and applied. A standard k-ℇ model in CFD commercial code FLUENT 6.3 was used for flow simulation. The flow simulation results showed that the turbulent intensity of flat plate-type was higher than slit-type under all gas velocity conditions and also the turbulent intensity of flat plate-type was increased continuously, but in case of slit-type was maintained at constant range. And, the turbulent intensity was decreased according to increasing of slit width. The experimental results showed that the collection efficiency of slit-type was higher than flat plate-type under all gas velocity conditions. And, over 6m/s gas velocity condition, the collection efficiency of 5mm and 7mm was highest, when compared to 3mm and 10mm.
참고문헌 (17)
- High velocity Electrostatic Precipitator for Road Tunnel, "Arao, Y.", ICESP-Australia, ~, pp.Paper 10B2 (2006)
- Cooperman, G., "A unified efficiency theory for electrostatic precipitators", Atmospheric Environment, 18, pp.277~285 (1984)
- Feldman, P. L., "Turbulent diffusion in electrostatic precipitator", AIChE, Symp. Ser, 73(165), pp.120~ (1977)
- Han B.W., "Effect oftrain-induced wind on tunnel ventilation in a subway tunnel", Korean Socity for Atmospheric Environment, PA65, pp.514~515 (2010)
- Kim J. R., "Development of road tunnel ventilation system with electrostatic precipitator", Thesocietyof air-conditioning and refrigerating engineers of Korea, pp.80~83 (2008), SAREK
- Kim J. R., "Study on discharge electrode design applied for road tunnel", The society of air-conditioning and refrigerating engineers of Korea, pp.1238~1243 (2009), SAREK
- Kim M.Y., "Evaluation onthe removal effect of PM10 and PM2.5 by operating the dust collection train and the washingtrain", Korean Society for Atmospheric Environment, PB9, pp.421~424 (2003)
- Kim Y. M., "Consideration forimproving ventilation system in subway tunnel after PSD(PlatformScreen Door) installation", Thesociety of air-conditioning andrefrigerating engineers of Korea, pp.666~671 (2009), SAREK
- Launder, B.E., "The numerical computation ofturbulent flows", Comp. Meth. Appl.Mech. Eng, 3, pp.269~ (1974)
- 이태정, "서울시 지하철 승강장의 스크린도어 설치 전∙후 PM10 오염원의 기여도 비교 연구", 한국대기환경학회지, 26(5), pp.543~553 (2010), 한국대기환경학회
- Meng, X., "A general empirical formula ofcurrent-voltag characteristics forpoint-to-plane geometry corona discharges", Journal of Physics D: Applied Physics, 41, pp.0652029~ (2008)
- Development ofElectrostatic Precipitator for Road Tunnel, "Miyake, K.", ICESP-Australia, ~, pp.Paper 10B1 (2006)
- Park S.H., "Effect of the black distance of collecting plate and particle size on the particle deposition efficiency in thetwo- stage electrostatic precipitator", Journal of Korean Society for Atmospheric Environment, 16(2), pp.165~177 (2000)
- 박종헌, "지하철 역사 미세먼지(PM10)의 확산방향과 확산속도 추정 (서울 지하철 5호선 개화산역을 대상으로)", 대한교통학회지, 28(5), pp.55~64 (2010), 대한교통학회
- Roh S. C., "A study on the electrostatic precipitator evolution for PM-10 elimination of subway station", The Korean society for railway, 4, pp.394~402 (2004)
- Transportationbusiness plan for Seoul Metropolitan Rapid Transit corporation, "Seoul Metropolitan Rapid TransitCorporation", ~ (2013)
- Yasumoto, K., "Improving Nano-particle collectionefficiency and suppressing particlere- entrainment in an AC electrostatic precipitator withhole-punched electrode", 11thInternational Conference Electrostatic Precipitation, pp.251~255 (2008)