In this study, we developed a separated two-stage electrostatic precipitator applicable in a subway air conditioning system. We studied the characteristics of collection efficiency of 0.3 μm particle and ozone generation at different charger sizes and gaps of collector plates. Also, we compared the performance of the two-stage ESP to the MERV 10 filter with the removal efficiency of 10% used in actual subway air conditioning system. The maximum collection efficiency of 0.3 μm particle was 93% at A charger (600 mm⨯250 mm⨯600 mm) and 84% at B charger (330 mm⨯280 mm⨯330 mm). Especially, with voltages applied to chargers with collection efficiency of about 80% or more, the ozone concentration of two different chargers was 5 ppb to 35 ppb. Finally, the filter quality of the collector developed in this study was 400 times higher than that of the MERV 10 filter. Therefore, it was concluded that the two-stage ESP could be a promising PM removal device suitable for subway air conditioning system.

Abstract

In this study, we developed a separated two-stage electrostatic precipitator applicable in a subway air conditioning system. We studied the characteristics of collection efficiency of 0.3 μm particle and ozone generation at different charger sizes and gaps of collector plates. Also, we compared the performance of the two-stage ESP to the MERV 10 filter with the removal efficiency of 10% used in actual subway air conditioning system. The maximum collection efficiency of 0.3 μm particle was 93% at A charger (600 mm⨯250 mm⨯600 mm) and 84% at B charger (330 mm⨯280 mm⨯330 mm). Especially, with voltages applied to chargers with collection efficiency of about 80% or more, the ozone concentration of two different chargers was 5 ppb to 35 ppb. Finally, the filter quality of the collector developed in this study was 400 times higher than that of the MERV 10 filter. Therefore, it was concluded that the two-stage ESP could be a promising PM removal device suitable for subway air conditioning system.

참고문헌 (14)

  1. Han, D. H., "Performance of respirator filters using quality factor in Korea", Industrial Health 2000, 38, pp.380~384 (2000)
  2. High air-flow aerosol filtration testing, "Hubbard, J. A.", ~, pp.SAND2018-10748 (2018)
  3. Kim, H. J., "Ozone emission and electrical characteristics of ionizers with different electrode materials, numbers, and diameters", IEEE Transactios on Industry Applications, 53, pp.459~465 (2016)
  4. Kim, J., "Integrated air quality management system for subway station and main line tunnel", Air Cleaning Technology, 23(2), pp.28~34 (2010)
  5. Kim, Y. S., "A study of improvement on the air filtering system of the subway", The Korean Society For Railway, pp.1075~1082 (2008)
  6. Kyung, D., "Fine dust treatment principle and trend of technology development", Korea Research Institute for Human Settlements, 452, pp.34~41 (2019)
  7. 이은선, "서울시 지하철 터널 내 입자상물질의 농도 특성 및 오염형태 분류", 한국대기환경학회지, 33(6), pp.593~604 (2017), 한국대기환경학회[DOI]
  8. Melody, S. M., "Maternal exposure to fine particulate matter from a large coal mine fire is associated with gestational diabetes mellitus : A prospective cohort study", Environmental Research, 183, pp.108956~ (2019)
  9. Noh, H., "The real-time air quality control system for subway stations and tunnels", Society of Air-Conditioning and Refrigerating Engineers of Korea, 42(5), pp.50~54 (2013)
  10. Petkus, A. J., "Exposure to fine particulate matter and temporal dynamics of episodic memory and depressive symptoms in older women", Environment International, 135, pp.105196~ (2020)
  11. "Status of public transportation use in Seoul" (2020)[URL]
  12. Hinds, W. C., "Aerosol Technology: properties, behavior, and measurement of airborne particles", pp.330~ (1999), John Wiley & Sons
  13. Zhang, Y., "Ambient fine particulate matter exposure induces cardiac functional injury and metabolite alterations in middle-aged female mice", Environmental Pollution, 248, pp.121~132 (2019)
  14. Zhao, Y., "Ambient fine and coarse particulate matter pollution and respiratory morbidity in Dongguan, China", Environmental Pollution, 222, pp.126~131 (2017)

관련 논문AI추천

이 간행물의 다른 논문 (4건)