본문 바로가기
KERD
논문KCI 등재

Hexokinase 방법을 이용한 Heparin 혈장과 NaF 혈장 시료의 혈당 분석치 비교

Comparison of Li-heparinized Versus Na-fluorinated Plasma for Routine Blood Glucose Determination Using Hexokinase Procedure

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기타자연과학

초록

.

Abstract

In this study, the two sampling methods for blood glucose measurement were evaluated in order to reduce pre-analytical error. For this purpose, glucose levels of Li-heparinized plasma (LHP) and Na-fluorinated plasma (NFP) in blood collected from healthy volunteers were determined by using routine hexokinase procedures. The percentage range of pre-analytical error was quantitated by comparing LHP glucose values with NFP glucose values according to delaying analytical time (0, 60, and 120 min). LHP glucose values were decreased by 6.6% in 60 min., 17.7% in 120 min, whereas NFP glucose values decreased by 1.1% in 60 min, 2.0% in 120 min. Therefore it may be recommended that the NFP sampling method should be used for routine blood glucose determination in diabetes mellitus diagnosis.

관련 논문AI추천

이 간행물의 다른 논문 (8건)