초록
Standardization of vitamin analysis continues around the world, and much effort has been made to improve the accuracy of the results. This study analyzed the sigma metrics of the vitamin D test using the external quality assessment (EQA) program. Sigma metrics is used for quantitative tests performed in the laboratory, and the test results can be objectively visualized in terms of quality. This analysis was performed based on the accuracy of the College of American Pathologists (CAP) using the results of the 2019 accuracy-based vitamin D (ABVD) survey, and about 300 laboratories participated in the survey. Reference values were obtained by the Center for Disease Control and Prevention (CDC) reference laboratory. At six different concentrations, the sigma metrics were analyzed to be 1.00, 1.85, 2.42, 1.01, 1.54 and 0.78, respectively. An average of 1.43 sigma metrics was determined. In particular, only positive biases for ABVD-16 and 17 were shown in the liquid chromatography tandem-mass spectrometry (LC-MS/MS), which is the standard method for vitamin D determination when compared to the reference values. The causes of the difference can be explained by cross reactivity to various vitamin D metabolites. Laboratories need to improve their overall performance.
Abstract
Standardization of vitamin analysis continues around the world, and much effort has been made to improve the accuracy of the results. This study analyzed the sigma metrics of the vitamin D test using the external quality assessment (EQA) program. Sigma metrics is used for quantitative tests performed in the laboratory, and the test results can be objectively visualized in terms of quality. This analysis was performed based on the accuracy of the College of American Pathologists (CAP) using the results of the 2019 accuracy-based vitamin D (ABVD) survey, and about 300 laboratories participated in the survey. Reference values were obtained by the Center for Disease Control and Prevention (CDC) reference laboratory. At six different concentrations, the sigma metrics were analyzed to be 1.00, 1.85, 2.42, 1.01, 1.54 and 0.78, respectively. An average of 1.43 sigma metrics was determined. In particular, only positive biases for ABVD-16 and 17 were shown in the liquid chromatography tandem-mass spectrometry (LC-MS/MS), which is the standard method for vitamin D determination when compared to the reference values. The causes of the difference can be explained by cross reactivity to various vitamin D metabolites. Laboratories need to improve their overall performance.
참고문헌 (36)
- MAURICE AUDRAN, "The Physiology and Pathophysiology of Vitamin D", Mayo Clinic Proceedings, 60(12), pp.851~866 (1985), Elsevier BV[DOI]
- Norman AW, "From vitamin D to hormone D : fundamentals of the vitamin D endocrine system essential for good health", Am J Clin Nutr, 88, pp.491~499 (2008)[DOI]
- Michael F. Holick, "Vitamin D Status: Measurement, Interpretation, and Clinical Application", Annals of Epidemiology, 19(2), pp.73~78 (2009), Elsevier BV[DOI]
- Bess Dawson-Hughes, "Estimates of optimal vitamin D status", Osteoporosis International, 16(7), pp.713~716 (2005), Springer Science and Business Media LLC[DOI]
- Carl J. Lavie, "Vitamin D and Cardiovascular Health", Circulation, 128(22), pp.2404~2406 (2013), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Holick MF, "Sunlight and vitamin D for bone health and prevention of autoimmune diseases, cancers, and cardiovascular disease", Am J Clin Nutr, 80, pp.1678s~1688s (2004)[DOI]
- Chantal Mathieu, "Vitamin D and type 1 diabetes mellitus: state of the art", Trends in Endocrinology & Metabolism, 16(6), pp.261~266 (2005), Elsevier BV[DOI]
- B. Dawson-Hughes, "IOF position statement: vitamin D recommendations for older adults", Osteoporosis International, 21(7), pp.1151~1154 (2010), Springer Science and Business Media LLC[DOI]
- Michael F. Holick, "Evaluation, Treatment, and Prevention of Vitamin D Deficiency: an Endocrine Society Clinical Practice Guideline", The Journal of Clinical Endocrinology & Metabolism, 96(7), pp.1911~1930 (2011), The Endocrine Society[DOI]
- Anna Woloszynska-Read, "Vitamin D and cancer: Clinical aspects", Best Practice & Research Clinical Endocrinology & Metabolism, 25(4), pp.605~615 (2011), Elsevier BV[DOI]
- Kazutake Shimada, "Gas chromatography and high-performance liquid chromatography of natural steroids", Journal of Chromatography A, 935(1-2), pp.141~172 (2001), Elsevier BV[DOI]
- 이제훈, "Current Recommendations for Laboratory Testing and Use of Bone Turnover Markers in Management of Osteoporosis", Annals of Laboratory Medicine, 32(2), pp.105~112 (2012), 대한진단검사의학회
- N. Binkley, "Assay Variation Confounds the Diagnosis of Hypovitaminosis D: A Call for Standardization", The Journal of Clinical Endocrinology & Metabolism, 89(7), pp.3152~3157 (2004), The Endocrine Society[DOI]
- Heinz Jürgen Roth, "Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography–tandem mass spectrometry as a reference", Annals of Clinical Biochemistry, 45(2), pp.153~159 (2008), SAGE Publications[DOI]
- P Glendenning, "Current assays overestimate 25-hydroxyvitamin D<SUB>3<", SUB> and underestimate 25-hydroxyvitamin D<SUB>2<, Annals of Clinical Biochemistry, pp.2006, 43(1)[DOI]
- Westgard JO, "The quality of laboratory testing today:an assessment of sigma metrics for analytic quality using performance data from proficiency testing surveys and the CLIA criteria for acceptable performance", Am J Clin Pathol, 125, pp.343~354 (2006)
- Neda Milinković, "Uncertainty of Measurement in Laboratory Medicine", Journal of Medical Biochemistry, 37(3), pp.279~288 (2018), Centre for Evaluation in Education and Science (CEON[DOI]
- "ABVD Participant Summary" (2013)[URL]
- Westgard JO, "Basic method validation" (2003), Westgard QC Inc
- Rukiye Nar, "The Evaluation of Analytical Performance of Immunoassay Tests by Using Six-Sigma Method", Journal of Medical Biochemistry, 36(4), pp.301~308 (2017), Centre for Evaluation in Education and Science (CEON[DOI]
- Patrick Erdman, "Accuracy-Based Vitamin D Survey: Six Years of Quality Improvement Guided by Proficiency Testing", Archives of Pathology & Laboratory Medicine, 143(12), pp.1531~1538 (2019), Archives of Pathology and Laboratory Medicine[DOI]
- Lind C, "Enzyme immunoassay for measuring 25-hydroxyvitamin D3 in serum", Clin Chem, 43, pp.943~949 (1997)
- Rosemary L. Schleicher, "Isotope dilution ultra performance liquid chromatography-tandem mass spectrometry method for simultaneous measurement of 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in human serum", Clinica Chimica Acta, 412(17-18), pp.1594~1599 (2011), Elsevier BV[DOI]
- Huiping Chen, "Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method", Clinica Chimica Acta, 391(1-2), pp.6~12 (2008), Elsevier BV[DOI]
- Zoë Maunsell, "Routine Isotope-Dilution Liquid Chromatography–Tandem Mass Spectrometry Assay for Simultaneous Measurement of the 25-Hydroxy Metabolites of Vitamins D2 and D3", Clinical Chemistry, 51(9), pp.1683~1690 (2005), Oxford University Press (OUP)[DOI]
- Mark M. Kushnir, "Rapid Analysis of 25-Hydroxyvitamin D 2 and D 3 by Liquid Chromatography–Tandem Mass Spectrometry and Association of Vitamin D and Parathyroid Hormone Concentrations in Healthy Adults", American Journal of Clinical Pathology, 134(1), pp.148~156 (2010), Oxford University Press (OUP)[DOI]
- Amy K. Saenger, "Quantification of Serum 25-Hydroxyvitamin D 2 and D 3 Using HPLC-Tandem Mass Spectrometry and Examination of Reference Intervals for Diagnosis of Vitamin D Deficiency", American Journal of Clinical Pathology, 125(6), pp.914~920 (2005), Oxford University Press (OUP)[DOI]
- Michael Vogeser, "Quantification of circulating 25-hydroxyvitamin D by liquid chromatography–tandem mass spectrometry", The Journal of Steroid Biochemistry and Molecular Biology, 121(3-5), pp.565~573 (2010), Elsevier BV[DOI]
- Carsten S. Højskov, "High-throughput liquid–liquid extraction and LCMSMS assay for determination of circulating 25(OH) vitamin D3 and D2 in the routine clinical laboratory", Clinica Chimica Acta, 411(1-2), pp.114~116 (2010), Elsevier BV[DOI]
- Laura A. G. Armas, "Vitamin D 2 Is Much Less Effective than Vitamin D 3 in Humans", The Journal of Clinical Endocrinology & Metabolism, 89(11), pp.5387~5391 (2004), The Endocrine Society[DOI]
- Houghton LA, "The case against ergocalciferol(vitamin D2)as a vitamin supplement", Am J Clin Nutr, 84, pp.694~697 (2006)[DOI]
- Bruce W. Hollis, "Assessment and Interpretation of Circulating 25-Hydroxyvitamin D and 1,25-Dihydroxyvitamin D in the Clinical Environment", Endocrinology and Metabolism Clinics of North America, 39(2), pp.271~286 (2010), Elsevier BV[DOI]
- Lanja Saleh, "Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS", MS) and three other automated assays, 2016, pp.54(4), 617~625[DOI]
- Sara P. Wyness, "Performance characteristics of six automated 25-hydroxyvitamin D assays: Mind your 3s and 2s", Clinical Biochemistry, 48(16-17), pp.1089~1096 (2015), Elsevier BV[DOI]
- Christopher-John L Farrell, "State-of-the-Art Vitamin D Assays: A Comparison of Automated Immunoassays with Liquid Chromatography–Tandem Mass Spectrometry Methods", Clinical Chemistry, 58(3), pp.531~542 (2012), Oxford University Press (OUP)[DOI]
- Marcel J.W. Janssen, "Multicenter comparison study of current methods to measure 25-hydroxyvitamin D in serum", Steroids, 77(13), pp.1366~1372 (2012), Elsevier BV[DOI]