중환자실에 근무하는 의료인의 전비강에서 PBP2a Rapid Kit와 직접 Coagulase 검사를 이용한 Methicillin-resistant Staphylococcus aureus의 검출
Detection of Methicillin-resistant Staphylococcs aureus from the Anterior Nares of Healthcare Workers in a Intensive Care Unit by Using PBP2a Rapid Kit and Direct Coagulase Test
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
.
Abstract
We evaluated the performance of a novel screening test, PBP2a MRSA rapid kit (Dinona Inc., Iksan, Korea), for methicillin-resistant Staphylococcus aureus (MRSA) based on a immunochromatographic assay. The test is able to detect penicillin-binding protein 2a (PBP2a) using the nasal specimens from health care workers. The nasal specimens were obtained from 69 healthcare workers and were incubated in enrichment broth followed eight hours incubatin in BHI with cefoxitin 4 μg/mL. These broth were tested by PBP2a Rapid Kit. The enrichment broths were also directly tested for tube coagulase using the conventional identification method. 19 of 22 MRSA showed positive results by PBP2a rapid test and direct coagulase test (the sensitivity for detection of MRSA, 86.36%). While, 8 of 47 non-MRSA showed false positive results for the two tests. All of the 8 non-MRSA which showed false positive were co-colonizing isolates with MRCNS and MSSA. In addition, 46 of 49 methicillin-resistant staphylococci (MRS) showed positive results for PBP2a MRSA rapid kit (the sensitivity for detection of MRS, 93.8%), and all of 20 non-MRS showed negative results (specificity, 100%). The combination of PBP2a MRSA rapid kit and direct coagulase test showed the good sensitivity for detection of MRSA from anterior nares but frequently showed false positive results from the co-colonizing carrier with MRCNS and MSSA.
참고문헌 (18)
- Ahn DH, "Evaluation of MRSASelect for detecting methicillinresistant Staphylococcus aureus from surveillance specimens", Korean J Nosocomial Infect Control, 12, pp.28~35 (2007)
- Becker K. Pagnier I, "Does nasal cocolonization by methicillin-resistant Coagulase-negative Staphylococci and methicillin-susceptible Staphylococcus aureus strains occur frequently enough to represent a risk of false-positive methicillin-resistant S. aureus determinations by molecular methods?", J Clin Microbiol, 44, pp.229~231 (2006)
- Bennett K, "Rapid differentiation of methicillin-resistant Staphylococcus aureus and methicillin-susceptible Staphylococcus aureus from blood cultures by use of a direct cefoxitin disk diffusion test", J Clin Microbiol, 46, pp.3836~3838 (2008)
- Cassandra D, "Communityacquired methicillin-resistant Staphylococcus aureus a meta-analysis of prevalence and risk factors", Clin Infect Dis, 36, pp.131~139 (2003)
- Chaix C, "Control of endemic methicillin-resistant Staphylococcus aureus: a cost-benefit analysis in anintensive care unit", JAMA, 282, pp.1745~1751 (1999)
- Clinical and Laboratory Standards Institute Performance standards for antimicrobial susceptibility testing. Sixteenth informational supplement, , ~, pp.CLSI document M100-S19 (2009)
- Cosgrove SE, "Comparison of mortality associated with methicillin-resistant and methicillin-susceptible Staphylococcus aureus bacteremia: a meta-analysis", Clin Infect Dis, 36(1), pp.53~59 (2003)
- Harbath SO, "Impact of methicillin resistance on the outcome of patients with bacteremia caused by Staphylococcus aureus", Arch Intern Med, 158, pp.182~189 (1998)
- Huletsky A, "New real-time PCR assay for rapid detection of methicillin-resistant Staphylococcus aureus directly from specimens containing a mixture of staphylococci", J Clin Microbiol, 42, pp.1875~1884 (2004)
- Kluytmans J, "Performance of CHROMagar selective medium and oxacillin resistance screening agar base for identifying Staphylococcus aureus and detecting methicillin resistance", J Clin Microbiol, 40, pp.2480~2482 (2002)
- Lee SO, "The investigation of surveillance culture for methicillinresistant Staphylococcus aureus in the nasal cavity of the patient at intensive care unit and the medical staffs", Korean J Clin Microbiol, 10(S1), pp.S84~ (2007)
- Louie L, "Rapid detection of methicillinresistant staphylococci from blood culture bottles by using a multiplex PCR assay", J Clin Microbiol, 40, pp.2786~2790 (2002)
- Perry JD, "Development and evaluation of a chromogenic agar medium for methicillinresistant Staphylococcus aureus", J Clin Microbiol, 42, pp.4519~4523 (2004)
- Rubinovitch B, "Screening for methicillinresistant Staphylococcus aureus in the endemic hospital:what have we learned?", J Hosp Infect, 47, pp.9~18 (2001)
- Ryoo NH, "Prevalence and epidemiological evaluations of nasal carriage of methicillin-resistant Staphylococcus aureus in hospital staffs", Korean J Clin Microbiol, 10(S1), pp.S83~ (2007)
- Sewell DL, "Sensitivity of surveillance cultures for the detection of methicillin-resistant Staphylococcus aureus in a nursing-home-care unit", Diagn Microbiol Infect Dis, 17, pp.53~56 (1993)
- Shin KS, "Development and evaluation of EZ-Step MRSA PBP2a rapid Kit for rapid detection of methicillin resistant Staphylococcus aureus from blood culture specimens", Korean Soc Lab Med 50th Congress P-MB-39 (2009)
- Stratidis J, "Use of real-time polymerase chain reaction for identification of methicillin-resistant Staphylococcus aureus directly from positive blood culture bottles", Diagn Microbiol Infect Dis, 58, pp.199~202 (2007)