Health Risk Assessment of Indoor Formaldehyde Exposure in Facilities for Medically Vulnerable People
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
A health risk assessment was conducted using indoor formaldehyde concentrations measured during a four-year period from 2019 to 2022 for 322 facilities within Busan Metropolitan City. In the facilities, the average concentration of formaldehyde was 26.7 μg/m3 for general hospitals, 27.4 μg/m3 for nursing hospitals, 17.8 μg/m3for daycare centers, 42.9 μg/m3 for postpartum care centers, and 14.1 μg/m3 for elderly care facilities. As for the health risk of formaldehyde, workers in hospitals, daycare centers, postpartum care centers, and elderly care facilities had ECR (excess cancer risk) values of 3.54 × 10-5, 2.84 × 10-5, 6.84 × 10-5, and 1.86 × 10-5 for CTE (central tendency exposure), respectively. Based on the Busan City ordinance seven out of 322 facilities in this study were found to be non-compliant. When the risk was calculated for individual data according to the exposure of workers in each facility, 303 ECR values (94%) exceeded 1.0 × 10-5. If excess cancer risk is calculated by assuming a gradual change in formaldehyde concentration, the current maintenance standard (70 μg/m3) is insufficient to provide appropriate safety for workers, patients and residents. Therefore, higher stringent values than 50 μg/m3 are required to obtain indoor air quality standards for formaldehyde that meet an ECR of 1.0 × 10-4.
Abstract
A health risk assessment was conducted using indoor formaldehyde concentrations measured during a four-year period from 2019 to 2022 for 322 facilities within Busan Metropolitan City. In the facilities, the average concentration of formaldehyde was 26.7 μg/m3 for general hospitals, 27.4 μg/m3 for nursing hospitals, 17.8 μg/m3for daycare centers, 42.9 μg/m3 for postpartum care centers, and 14.1 μg/m3 for elderly care facilities. As for the health risk of formaldehyde, workers in hospitals, daycare centers, postpartum care centers, and elderly care facilities had ECR (excess cancer risk) values of 3.54 × 10-5, 2.84 × 10-5, 6.84 × 10-5, and 1.86 × 10-5 for CTE (central tendency exposure), respectively. Based on the Busan City ordinance seven out of 322 facilities in this study were found to be non-compliant. When the risk was calculated for individual data according to the exposure of workers in each facility, 303 ECR values (94%) exceeded 1.0 × 10-5. If excess cancer risk is calculated by assuming a gradual change in formaldehyde concentration, the current maintenance standard (70 μg/m3) is insufficient to provide appropriate safety for workers, patients and residents. Therefore, higher stringent values than 50 μg/m3 are required to obtain indoor air quality standards for formaldehyde that meet an ECR of 1.0 × 10-4.
참고문헌 (14)
- International agency for research on cancer(IARC), "IARC monographs on the evaluation of the carcinogenic risk of chemicals to humans, In: Formaldehyde", ~ (2006)
- US Environmental protection agency, "Indoor Air Quality (IAQ)", ~ (2007)
- 국가우선순위물질 관리방안 마련을 위한 연구(I), "국립환경과학원", ~ (2011)
- "US Environmental protection agency"[URL]
- W. D. Kerns, "Carcinogenicity of formaldehyde in rats and mice after long-term inhalation exposure", Cancer research, 43, pp.4382~4392 (1983)
- 박태현, "서울시 내 민감계층 이용시설에서 오염물질의 분포특성", 실내환경 및 냄새 학회지, 16(4), pp.345~355 (2017), 한국냄새환경학회[DOI]
- 안지희, "보육시설, 산후조리원의 실내공기질 농도 및 위해성평가", 실내환경 및 냄새 학회지, 17(4), pp.337~345 (2018), 한국냄새환경학회[DOI]
- 환경부, "한국노출계수핸드북", ~ (2007)
- 국립환경과학원, "어린이노출계수핸드북", ~ (2016)
- 건강보험통계, "국민건강보험공단", ~ (2021)
- 국민보건의료실태조사, "국민건강보험공단", ~ (2022)
- 2021년 전국보육실태조사-어린이집 조사 보고, "양미선", 보건복지부, ~ (2021)
- 류인철, "다중이용시설 실내공기질 특성 및 건강위해성평가에 대한 연구", 박사, 지구환경공학, pp.2010
- 위해성기준 설정방안 연구(최종보고서), "환경부", ~ (2008)