감법을 이용한 실리콘 오일 기반의 2채널 광섬유 온도 센서
Silicon Oil-Based 2-Channel Fiber-Optic Temperature Sensor Using a Subtraction Method
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
We developed a 2-channel fiber-optic temperature sensor (FOTS) using a temperature sensing probe, a fiber-optic coupler, transmitting optical fiber, and an optical time domain reflectometer (OTDR). The temperature sensing probe is divided into a sensing probe and a reference probe for accurate thermometry. A sensing probe is composed of a silicon oil, a FC terminator, a brass pipe, and a single-mode optical fiber and the structure of a reference probe is identical with that of the sensing probe excluding a silicon oil. In this study, we measured the modified optical powers of the light signals reflected from the temperature sensing probe placed inside of the water with a thermal variation from 5 to 70℃. Although the optical power of the reference probe was constant regardless of the temperature change, the optical power of the sensing probe decreased linearly as the temperature increased. As experimental results, the FOTS using a subtraction method showed a small difference (i.e., hysteresis) in its response due to heating and cooling. The reversibility and reproducibility of the FOTS were also evaluated.
Abstract
We developed a 2-channel fiber-optic temperature sensor (FOTS) using a temperature sensing probe, a fiber-optic coupler, transmitting optical fiber, and an optical time domain reflectometer (OTDR). The temperature sensing probe is divided into a sensing probe and a reference probe for accurate thermometry. A sensing probe is composed of a silicon oil, a FC terminator, a brass pipe, and a single-mode optical fiber and the structure of a reference probe is identical with that of the sensing probe excluding a silicon oil. In this study, we measured the modified optical powers of the light signals reflected from the temperature sensing probe placed inside of the water with a thermal variation from 5 to 70℃. Although the optical power of the reference probe was constant regardless of the temperature change, the optical power of the sensing probe decreased linearly as the temperature increased. As experimental results, the FOTS using a subtraction method showed a small difference (i.e., hysteresis) in its response due to heating and cooling. The reversibility and reproducibility of the FOTS were also evaluated.
참고문헌 (12)
- 장재석, "OTDR을 이용한 실리콘 오일 기반의 광섬유 온도 센서", 전기학회논문지, 64(11), pp.1592~1597 (2015), 대한전기학회[DOI]
- 최영, "원자력발전소의 냉각재상실사고 특성DB를 활용한 중대사고 관리체계연구", 한국안전학회지, 29(6), pp.172~178 (2014), 한국안전학회
- 강한옥, "일체형원자로 인쇄기판형 증기발생기 열수력학적 설계", 한국유체기계학회 논문집, 17(6), pp.77~83 (2014), 한국유체기계학회
- Xuming Lv ,, "LEAK-BEFORE-BREAK ANALYSIS OF THERMALLY AGED NUCLEAR PIPE UNDER DIFFERENT BENDING MOMENTS", Nuclear Engineering and Technology, 47(6), pp.712~718 (2015), 한국원자력학회
- 박재학, "ESTIMATION OF LEAK RATE THROUGH CIRCUMFERENTIAL CRACKS IN PIPES IN NUCLEAR POWER PLANTS", Nuclear Engineering and Technology, 47(3), pp.332~339 (2015), 한국원자력학회
- M. Wang, "Research on the leak-rate characteristics of leak-before-break(LBB)in pressurized water reactor(PWR)", Applied Thermal Engineering, 62(1), pp.133~140 (2014)
- T. S. Kim, "Laser-based sensor for a coolant leak detection in a nuclear reactor", Applied Physics B, 100(2), pp.437~442 (2010)
- 심혁인, "광섬유와 OTDR을 이용한 실시간 수위 및 온도 측정", 전기학회논문지, 63(9), pp.1239~1244 (2014), 대한전기학회[DOI]
- W. J. Yoo, "Fabrication and comparison of thermochromic material-based fiber-optic sensors for measuring the temperature of water", Optical review, 18(1), pp.144~148 (2011)
- 신상훈, "사용후핵연료 집합체 모사장치를 이용한 광섬유 체렌코프 방사선 센서 시스템의 성능평가", 센서학회지, 23(4), pp.245~250 (2014), 한국센서학회[DOI]
- Q. Li, "Fiber-optic distributed sensor based on phase-sensitive OTDR and wavelet packet transform for multiple disturbances location", Optik, 125(24), pp.7235~7238 (2014)
- 김대현, "광시간영역 반사계를 이용한 분포형 광섬유 과열 감지 센서", 센서학회지, 22(4), pp.297~301 (2013), 한국센서학회[DOI]