본문 바로가기
KERD
논문KCI 등재

순음 청력검사를 위한 원격진단 모니터링 시스템

Remote Patient Monitoring System for Diagnostic Pure-tone Audiometry

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류공학일반

초록

This paper presents a remote patient monitoring system for diagnostic pure-tone audiometry. A pure-tone audiometer was developed for basic hearing screening; its performance was evaluated according to international standards in terms of linearity, accuracy, and total harmonic distortion. Pure-tone audiometry has a maximum hearing level of 104.9 dB HL that is comparable with other commercial products. The audiometer shows satisfactory linearity with a deviation of ±0.4 dB, an accuracy of ±0.025%, and a total harmonic distortion(THD) of 0.21%. The remote patient monitoring systems include remote control devices based on wide area network (WAN) connections and an audiometer connected in series. Through experimentation, we successfully performed real-time diagnostic communication without delay in transferring audiometric data. This system is expected to supply domestic equipment in the audiometric market and to improve the quality of life of patients in non-clinical environments.

Abstract

This paper presents a remote patient monitoring system for diagnostic pure-tone audiometry. A pure-tone audiometer was developed for basic hearing screening; its performance was evaluated according to international standards in terms of linearity, accuracy, and total harmonic distortion. Pure-tone audiometry has a maximum hearing level of 104.9 dB HL that is comparable with other commercial products. The audiometer shows satisfactory linearity with a deviation of ±0.4 dB, an accuracy of ±0.025%, and a total harmonic distortion(THD) of 0.21%. The remote patient monitoring systems include remote control devices based on wide area network (WAN) connections and an audiometer connected in series. Through experimentation, we successfully performed real-time diagnostic communication without delay in transferring audiometric data. This system is expected to supply domestic equipment in the audiometric market and to improve the quality of life of patients in non-clinical environments.

참고문헌 (13)

  1. 정승원, "청각장애인의 장애수용이 자아존중감에 미치는 전망적 효과에 관한 연구", 장애와 고용, 24(1), pp.167~197 (2014), 한국장애인고용공단 고용개발원[DOI]
  2. 고민석, "장애노인의 사회참여가 일상생활만족도에 미치는 영향: 주관적 건강상태와 자아존중감의 매개효과", 보건의료산업학회지, 9(3), pp.221~232 (2015), 보건의료산업학회
  3. M. R. Dix, "Modern developments in pure tone audiometry and their application to the clinical diagnosis of end-organ deafness", J. Laryngol. Otol., 67(6), pp.343~357 (1953)
  4. C. Raymond, "Preferred method for clinical determination of pure-tone thresholds", J. Speech Hear. Disord., 24(4), pp.330~345 (1959)
  5. S. A. Gelfnd, "Essentials of Audiology" (2009), Thieme Medical Publishers
  6. Ji-Young Oh, "Current Status and Progress of Telemedicine in Korea and Other Countries", Healthcare Informatics Research, 21(4), pp.239~243 (2015), 대한의료정보학회[DOI]
  7. M. Marcin, "Hearing tests on mobile devices : evaluation of the reference sound level by means of biological calibration", J. Med. Internet Res., 18(5), pp.1~12 (2016)
  8. N. Nakamura, "Development of"MobileAudiometer"for screening using mobile phones", The 26th Ann. Int. Conf. IEEE Eng. in Med. Biol. Soc., pp.3369~3372 (2004)
  9. F. N. Martin, "Introduction to Audiology" (2014), Pearson Education
  10. Accredited Standartds Committee S3, "Specification for audiometers", ANSI, 2010
  11. 이강호, "청력선별형 순음 청력검사기의 개발", Audiology and Speech Research, 12(3), pp.144~149 (2016), 한국청각언어재활학회
  12. IEC technical committee 29, "Electroacoustics-Audiometric equipment-Part 1: Equipment for pure-tone audiometry", IEC 60645-1, filing date, ~ (2012)

관련 논문AI추천

이 간행물의 다른 논문 (11건)