본문 바로가기
KERD
논문KCI 등재

저작운동으로 인한 진동 잡음 신호의 경감을 위한 측두골 이식형 마이크로폰의 설계

The Design of Temporal Bone Type Implantable Microphone for Reduction of the Vibrational Noise due to Masticatory Movement

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류공학일반

초록

A microphone for fully implantable hearing device was generally implanted under the skin of the temporal bone. So, the implanted microphone’s characteristics can be affected by the accompanying noise due to masticatory movement. In this paper, the implantable microphone with 2-channels structure was designed for reduction of the generated noise signal by masticatory movement. And an experimental model for generation of the noise by masticatory movement was developed with considering the characteristics of human temporal bone and skin. Using the model, the speech signal by a speaker and the artificial noise by a vibrator were supplied simultaneously into the experimental model, the electrical signals were measured at the proposed microphone. The collected signals were processed using a general adaptive filter with least mean square(LMS) algorithm. To confirm performance of the proposed methods, the correlation coefficient and the signal to noise ratio(SNR) before and after the signal processing were calculated. Finally, the results were compared each other.

Abstract

A microphone for fully implantable hearing device was generally implanted under the skin of the temporal bone. So, the implanted microphone’s characteristics can be affected by the accompanying noise due to masticatory movement. In this paper, the implantable microphone with 2-channels structure was designed for reduction of the generated noise signal by masticatory movement. And an experimental model for generation of the noise by masticatory movement was developed with considering the characteristics of human temporal bone and skin. Using the model, the speech signal by a speaker and the artificial noise by a vibrator were supplied simultaneously into the experimental model, the electrical signals were measured at the proposed microphone. The collected signals were processed using a general adaptive filter with least mean square(LMS) algorithm. To confirm performance of the proposed methods, the correlation coefficient and the signal to noise ratio(SNR) before and after the signal processing were calculated. Finally, the results were compared each other.

참고문헌 (12)

  1. N. Yazdi, "Micromachined inertial sensors", Proc. IEEE, 86(8), pp.1640~1659 (1998)
  2. N. Barbour, "Inertial sensor technology trends", IEEE Sensors Journal, 1(4), pp.332~339 (2001)
  3. A. A. Seshia, "A vacuum packaged surface micromachined resonant accelerometer", J. Microelectromech. Syst., 11(6), pp.784~793 (2002)
  4. S. X. P. Su, "A resonant accelerometer with two-stage microleverage mechanisms fabricated by SOI-MEMS technology", IEEE Sensors Journal, 5(6), pp.1214~1223 (2005)
  5. L. He, "A CMOS readout circuit for SOI resonant accelerometer with 4-μg bias stability and 20-μg", √Hz resolution, 2008, pp.43, 1480~1490
  6. O. Le Traon, "Monolithic differential vibrating beam accelerometer within an isolating system between the two resonators", Proc. IEEE Sensors Conf., pp.648~651 (2005)
  7. S. Seok, "Inertial-grade in-plane resonant silicon accelerometer", Electronics Letters, 42(19), pp.1092~1093 (2006)
  8. W. C. Young, "Roark's Formulas for Stress and Strain (7th Edition)", pp.229~ (2002), McGraw-Hill
  9. W. D. Sawyer, "SOI bonded wafer process for high precision MEMS inertial sensors", J. Micromech. Microeng., 15, pp.1588~1593 (2005)
  10. C. A. Choi, "Stress characteristics of multilayer polysilicon for the fabrication of micro resonators", J. Kor. Sensors Soc., 8(1), pp.53~62 (1999)
  11. 최범규, "SOG(Sillicon On Glass)공정을 이용한 수평형 미소가속도계의 제작에 관한 연구", 센서학회지, 13(6), pp.430~435 (2004), 한국센서학회
  12. X. Ding, "Residual stress and mechanical properties of boron-doped p+- silicon films", Sensors and Actuators A: Physical, 23, pp.866~871 (1990)

관련 논문AI추천

피부에 의한 이득 감쇠를 줄이기 위한 FEA 시뮬레이션 기반의 이식형 마이크로폰 설계 및 구현김동욱, 김민우, 박일용, 성기웅, 조성목, 조진호, 한지훈대한의용생체공학회 · 의공학회지2008 · 제29권 제1호완전 이식형 보청기 기술 평가 기반의 새로운 이식형 음향센서 제안성기웅, 우승탁, 이승하, 이정현, 임형규, 정의성, 조진호한국센서학회 · 센서학회지2014 · 제23권 제3호Design of an Implantable Microphone for Artificial Middle Ear System김명남, 김민교, 박일용, 송병섭, 윤영호, 이정현, 임형규, 조진호대한의용생체공학회 · 의공학회지2005 · 제26권 제3호이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰김동욱, 김명남, 성기웅, 이장우, 이정현, 임형규, 정의성, 조진호한국센서학회 · 센서학회지2010 · 제19권 제5호중이 이식형 보청기에서 DFMT의 진동에 의한 등골 및 고막 방향으로 전달되는 진동력 측정김동욱, 김민우, 성기웅, 이규엽, 이명원, 이상흔, 이장우, 이정현, 임형규, 정의성, 조진호한국센서학회 · 센서학회지2009 · 제18권 제4호이소골에 장착된 전자기 플로팅매스 진동체에 대한 집중 질량-스프링 모델의 제안김동욱, 김명남, 김민우, 박일용, 성기웅, 이규엽, 이명원, 이상흔, 이장우, 이정현, 임형규, 정의성, 조진호대한의용생체공학회 · 의공학회지2009 · 제30권 제2호

이 간행물의 다른 논문 (11건)