This paper deals with relative position estimation using a Kalman filter (KF) based on inertial sensors that have been widely used in various biomechanics-related outdoor applications. In previous studies, the relative position is determined using relative orientationand predetermined segment-to-joint (S2J) vectors, which are assumed to be constant. However, because body segments are influenced by soft tissue artifacts (STAs), including the deformation and sliding of the skin over the underlying bone structures, they are not constant,resulting in significant errors during relative position estimation. In this study, relative position estimation was performed using a KF, where the S2J vectors were adopted as time-varying states. The joint constraint and the variations of the S2J vectors were usedto develop a measurement model of the proposed KF. Accordingly, the covariance matrix corresponding to the variations of the S2J vectors continuously changed within the ranges of the STA-causing flexion angles. The experimental results of the knee flexion testsshowed that the proposed KF decreased the estimation errors in the longitudinal and lateral directions by 8.86 and 17.89 mm, respectively, compared with a conventional approach based on the application of constant S2J vectors.

Abstract

This paper deals with relative position estimation using a Kalman filter (KF) based on inertial sensors that have been widely used in various biomechanics-related outdoor applications. In previous studies, the relative position is determined using relative orientationand predetermined segment-to-joint (S2J) vectors, which are assumed to be constant. However, because body segments are influenced by soft tissue artifacts (STAs), including the deformation and sliding of the skin over the underlying bone structures, they are not constant,resulting in significant errors during relative position estimation. In this study, relative position estimation was performed using a KF, where the S2J vectors were adopted as time-varying states. The joint constraint and the variations of the S2J vectors were usedto develop a measurement model of the proposed KF. Accordingly, the covariance matrix corresponding to the variations of the S2J vectors continuously changed within the ranges of the STA-causing flexion angles. The experimental results of the knee flexion testsshowed that the proposed KF decreased the estimation errors in the longitudinal and lateral directions by 8.86 and 17.89 mm, respectively, compared with a conventional approach based on the application of constant S2J vectors.

참고문헌 (22)

  1. G. Pons-Moll, "Multisensor-fusion for 3D full-body human motion capture", Proc. of IEEE Conf. on Comput. Vis. Pattern Recognit, pp.663~670 (2010)
  2. M. Kok, "An optimizationbased approach to human body motion capture using inertial sensors", Proc. of 19th World Congr. Int. Fed. Autom. Control, pp.79~85 (2014)
  3. A. Atrsaei, "Human arm motion tracking by inertial", magnetic sensors using unscented Kalman filter and relative motion constraint, 2018, pp.90, 161~170
  4. G. Cooper, "Inertial sensor-based knee flexion", extension angle estimation, 2009, pp.42(16), 2678~2685
  5. B. Fasel, "Joint inertial sensor orientation drift reduction for highly dynamic movements", IEEE J. Biomed. Health Inform, 22(1), pp.77~86 (2018)
  6. 전태형, "IMU-Based Joint Angle Estimation Under Various Walking and Running Conditions", 한국정밀공학회지, 35(12), pp.1199~1204 (2018), 한국정밀공학회
  7. J. Favre, "Ambulatory measurement of 3D knee joint angle", J. Biomech, 41(5), pp.1029~1035 (2008)
  8. J. K. Lee, "Magnetic condition-independent 3D joint angle estimation using inertial sensors and kinematic constraints", Sensors, 19(24), pp.5522(1)~5522(14) (2019)
  9. A. Szczęsna, "Model-based extended quaternion Kalman filter to inertial orientation tracking of arbitrary kinematic chains", SpringerPlus, 5, pp.1965(1)~1965(13) (2016)
  10. 윤득선, "GPS와 INS의 센서융합을 이용한 자율항법용 확장형 칼만필터 설계", 센서학회지, 16(4), pp.294~300 (2007), 한국센서학회
  11. H. J. Luinge, "Measuring orientation of human body segments using miniature gyroscopes and accelerometers", Med. Biol. Eng. Comput, 43, pp.273~282 (2005)
  12. Woo-Chang Jung, "Constraint-Combined Adaptive Complementary Filter for Accurate Yaw Estimation in Magnetically Disturbed Environments", 센서학회지, 28(2), pp.81~87 (2019), 한국센서학회
  13. J. K. Lee, "Robust inertial measurement unitbased attitude determination Kalman filter for kinematically constrained links", Sensors, 19(4), pp.768(1)~768(11) (2019)
  14. J. Cameron, "A real-time sequential algorithm for human joint localization", Proc. of ACM SIGGRAPH 2005, pp.107~ (2005)
  15. T. Seel, "Joint axis and position estimation from inertial measurement data by exploiting kinematic constraints", Proc. of IEEE Int. Conf. on Control Appl, pp.45~49 (2012)
  16. 이정근, "Verification of Two Least-Squares Methods for Estimating Center of Rotation Using Optical Marker Trajectory", 센서학회지, 26(6), pp.371~378 (2017), 한국센서학회[DOI]
  17. R. S. McGinnis, "Inertial sensor based method for identifying spherical joint center of rotation", J. Biomech, 46(14), pp.2546~2549 (2013)
  18. M. Gabiccini, "A data-driven kinematic model of the human hand with softtissue artifact compensation mechanism for grasp synergy analysis", Proc. of IEEE, 2013, 3738~3745
  19. R. Dumas, "Soft tissue artifact compensation by linear 3D interpolation and approximation methods", J. Biomech, 42(13), pp.2214~2217 (2009)
  20. V. Camomilla, "A model of the soft tissue artefact rigid component", J. Biomech, 48(10), pp.1752~1759 (2015)
  21. V. Richard, "Comparative assessment of knee joint models used in multi-body kinematics optimisation for soft tissue artefact compensation", J. Biomech, 62, pp.95~101 (2017)
  22. E. Frick, "Joint center estimation using single-frame optimization : Part 1 : Numerical simulation", Sensors, 18(4), pp.1089(1)~1089(17) (2018)