연조직 변형에 의한 해부학적 지표와 피부마커의 변위 상관성을 이용한 동작분석 오차 보정 방법의 적용
Application of Compensation Method of Motion Analysis Error Using Displacement Dependency between Anatomical Landmarks and Skin Markers Due to Soft Tissue Artifact
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Of many approaches to reduce motion analysis errors, the compensation method of anatomical landmarks estimates the position of anatomical landmarks during motion. The method models the position of anatomical landmarks with joint angle or skin marker displacement using the data of the so-called dynamic calibration in which anatomical landmark positions are calibrated in ad hoc motions. Then the anatomical landmark positions are calibrated in target motions using the model. This study applies the compensation methods with joint angle and skin marker displacement to three lower extremity motions (walking, sit-to-stand/stand-to-sit, and step up/down) in ten healthy males and compares their performance. To compare the performance of the methods,two sets of kinematic variables were calculated using different two marker clusters, and the difference was obtained. Results showed that the compensation method with skin marker displacement had less differences by 30~60% compared to without compensation. And, it had significantly less difference in some kinematic variables (7 of 18) by 25~40% compared to the compensation method with joint angle. This study supports that compensation with skin marker displacement reduced the motion analysis STA errors more reliably than with joint angle in lower extremity motion analysis.
Abstract
Of many approaches to reduce motion analysis errors, the compensation method of anatomical landmarks estimates the position of anatomical landmarks during motion. The method models the position of anatomical landmarks with joint angle or skin marker displacement using the data of the so-called dynamic calibration in which anatomical landmark positions are calibrated in ad hoc motions. Then the anatomical landmark positions are calibrated in target motions using the model. This study applies the compensation methods with joint angle and skin marker displacement to three lower extremity motions (walking, sit-to-stand/stand-to-sit, and step up/down) in ten healthy males and compares their performance. To compare the performance of the methods,two sets of kinematic variables were calculated using different two marker clusters, and the difference was obtained. Results showed that the compensation method with skin marker displacement had less differences by 30~60% compared to without compensation. And, it had significantly less difference in some kinematic variables (7 of 18) by 25~40% compared to the compensation method with joint angle. This study supports that compensation with skin marker displacement reduced the motion analysis STA errors more reliably than with joint angle in lower extremity motion analysis.
참고문헌 (14)
- Alexander, E.J., "Correction for deformation in skin-based marker systems", Journal of Biomechanics, 34, pp.355~361 (2001)
- Ball, K.A., "Modeling of the pliant surfaces of the thigh and leg during gait", Proceedings of SPIE-the international society for optical engineering, 3254, pp.435~446 (1998)
- Challis, J.H., "A procedure for determining rigid body transformation parameters", Journal of Biomechanics, 28(6), pp.733~777 (1995)
- Cappello, A., "Multiple anatomical landmark calibration for optimal bone pose estimation", Human Movement Science, 16, pp.259~274 (1997)
- Cappello, A., "Soft tissue artifact compensation in knee kinematics by double anatomical landmark calibration : Performance of a novel method during selected motor tasks", IEEE Transactions on Biomedical Engineering, 52, pp.992~998 (2005)
- Cappozzo, A., "Position and orientation in space of bones during movement : anatomical frame definition and determination", Clinical Biomechanics, 10(4), pp.171~178 (1995)
- Cappozzo, A., "Position and orientation in space of bones during movement: experimental artifact", Clinical Biomechanics, 11(2), pp.90~100 (1996)
- Ehara, Y., "Comparison of the performance of 3D camera systems II", Gait and Posture, 5, pp.251~255 (1997)
- Fuller, J., "A comparison of lower-extremity skeletal kinematics measured using skin- and pin-mounted markers", Human Movement Science, 16, pp.219~242 (1997)
- Holden, J.P., "Surface movement error in shank kinematics and knee kinetics during gait", Gait and Posture, 5, pp.217~227 (1997)
- Lucchetti, L., "Skin movement artifact assessment and compensation in the estimation of knee-joint kinematics", Journal of Biomechanics, 31, pp.977~984 (1998)
- Piazza, S. J., "Assessment of the functional method of hip joint center location subject to reduced range of hip motion", Journal of Biomechanics, 37, pp.349~356 (2004)
- Reinschmidt, C., "Tibiofemoral and tibiocalcaneal motion during walking : external vs. Skeletal markers", Gait and Posture, 6, pp.98~109 (1997)
- Ryu, T., "Soft tissue artifact compensation using displacement dependency between anatomical landmarks and skin markers - a preliminary study", INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 39, pp.152~158 (2009), Elsevier