본문 바로가기
KERD
논문KCI 등재

초 고온·고압 소결 공정으로 제조된 다결정 다이아몬드 컴팩트(PDC)의 미세조직 및 열충격 특성에 미치는 다이아몬드 입자 비율의 영향

Effect of Diamond Particle Ratio on the Microstructure and Thermal Shock Property of HPHT Sintered Polycrystalline Diamond Compact (PDC)

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류금속공학

초록

This study investigates the microstructure and thermal shock properties of polycrystalline diamond compact (PDC) produced by the high-temperature, high-pressure (HPHT) process. The diamond used for the investigation features a 12~22 μm- and 8~16 μm-sized main particles, and 1~2 μm-sized filler particles. The filler particle ratio is adjusted up to 5~31% to produce a mixed particle, and then the tap density is measured. The measurement finds that as the filler particle ratio increases, the tap density value continuously increases, but at 23% or greater, it reduces by a small margin. The mixed particle described above undergoes an HPHT sintering process. Observation of PDC microstructures reveals that the filler particle ratio with high tap density value increases direct bonding among diamond particles, Co distribution becomes even, and the Co and W fraction also decreases. The produced PDC undergoes thermal shock tests with two temperature conditions of 820 and 830, and the results reveals that PDC with smaller filler particle ratio and low tap density value easily produces cracks, while PDC with high tap density value that contributes in increased direct bonding along with the higher diamond content results in improved thermal shock properties.

Abstract

This study investigates the microstructure and thermal shock properties of polycrystalline diamond compact (PDC) produced by the high-temperature, high-pressure (HPHT) process. The diamond used for the investigation features a 12~22 μm- and 8~16 μm-sized main particles, and 1~2 μm-sized filler particles. The filler particle ratio is adjusted up to 5~31% to produce a mixed particle, and then the tap density is measured. The measurement finds that as the filler particle ratio increases, the tap density value continuously increases, but at 23% or greater, it reduces by a small margin. The mixed particle described above undergoes an HPHT sintering process. Observation of PDC microstructures reveals that the filler particle ratio with high tap density value increases direct bonding among diamond particles, Co distribution becomes even, and the Co and W fraction also decreases. The produced PDC undergoes thermal shock tests with two temperature conditions of 820 and 830, and the results reveals that PDC with smaller filler particle ratio and low tap density value easily produces cracks, while PDC with high tap density value that contributes in increased direct bonding along with the higher diamond content results in improved thermal shock properties.

참고문헌 (14)

  1. F. Bellin, , World Oil, 231, pp.41~ (2010)
  2. D. Belnap, , Dia. Rel. Mater., 13, pp.1914~ (2004)
  3. D. E. Scott, , Ind. Diamond Rev., 1, pp.48~ (2006)
  4. D. Jianxin, , Int. J. Refract. Met. Hard Mater., 29, pp.631~ (2011)
  5. M. V. Sneddon, , J. Petroleum Technol., 40, pp.1593~ (1988)
  6. D. Miess, , Mater. Sci. Eng. A, 209, pp.270~ (1996)
  7. H. T. Hall, , Science, 169, pp.868~ (1970)
  8. R. H. Wentorf, , Science, 208, pp.873~ (1980)
  9. C. Liu, , Int. J. Refract. Met. Hard Mater., 31, pp.187~ (2012)
  10. R. L. Mehan, , J. Sci., 24, pp.942~ (1989)
  11. L. Tze-Pin, , Wear, 156, pp.133~ (1992)
  12. S. M. K. Rassouly, , Powder Technol., 103, pp.145~ (1999)
  13. R. M. German, , Metall. Mater. Trans. A, 23, pp.1455~ (1992)
  14. 박희섭, "초고압 소결된 다이아몬드", 실리콘 카바이드 복합재료의 계면특성 및 기계적 특성, 2009, pp.16(6), 416~423[DOI]