This paper addresses experimental methodologies to measure the temperature-dependent thermal conductivity of the insulation materials popularly used for LNG cargo containment systems. The measurement techniques considered in this paper are the guarded hot plate (GHP) method and heat flow method (HFM). The former is based on the power supplied to the hot plate to keep the temperature constant, and the latter is based on a direct heat flux measurement. In order to improve the accuracy of the HFM, the thermal conductivity obtained by GHP was cross-compared with the HFM results, and a calibration factor was derived. It was found that the thermal conductivities measured by the two methods corresponded well under room temperature, but the deviation tended to slightly increase as the temperature decreased. Because of the easy installation and operability of HFM, it can be used to measure thermal conductivity in a large scale mock-up test or unit insulation panel test, where the GHP method is difficult to apply.
Abstract
This paper addresses experimental methodologies to measure the temperature-dependent thermal conductivity of the insulation materials popularly used for LNG cargo containment systems. The measurement techniques considered in this paper are the guarded hot plate (GHP) method and heat flow method (HFM). The former is based on the power supplied to the hot plate to keep the temperature constant, and the latter is based on a direct heat flux measurement. In order to improve the accuracy of the HFM, the thermal conductivity obtained by GHP was cross-compared with the HFM results, and a calibration factor was derived. It was found that the thermal conductivities measured by the two methods corresponded well under room temperature, but the deviation tended to slightly increase as the temperature decreased. Because of the easy installation and operability of HFM, it can be used to measure thermal conductivity in a large scale mock-up test or unit insulation panel test, where the GHP method is difficult to apply.
참고문헌 (14)
- Standard Test Method for Steady-State Thermal Transmission Properties by Mean of the Heat Flow Meter Apparatus, "ASTM", American Society for Testing and Materials, ~, pp.ASTM C518-02 (2004)
- Bomberg, M., "Comments on Calibration and Design of a Heat Flow Meter. American Society for Testing and Materials(ASTM)", American Society for Testing and Materials(ASTM), STP 789, pp.277~292 (1983)
- 장철웅, "멤브레인 LNG 선박용 강화 폴리우레탄폼의 극저온 거동 연구", 한국해양공학회지, 27(1), pp.74~79 (2013), 한국해양공학회
- Kim, B. S., "Fabrication and Calibration of Micro Heat Flux Sensor for Heat Flux Measurement", Proceedings of KSME 2005 Autumn Annual Meeting, pp.195~199 (2005)
- Kim, J. G., "A Study on Unsteady Temperature Distribution Analysis of Moss Type LNG Carrier by Insulation System", Journal of Ocean Engineering and Technology, 11(4), pp.159~168 (1997)
- 이장현, "LNG 화물창 방열재 균열에 따른 액화천연가스의 확산 및 온도 예측을 위한 수치 모델", 한국해양공학회지, 28(6), pp.517~526 (2014), 한국해양공학회
- 이진성, "LNG CCS적용을 위한 고망간강의 극저온 피로성능 평가", 대한조선학회 논문집, 51(3), pp.246~253 (2014), 대한조선학회
- 이진성, "An experimental study on fatigue performance of cryogenic metallic materials for IMO type B tank", International Journal of Naval Architecture and Ocean Engineering, 5(4), pp.580~597 (2013), 대한조선학회
- "Heat Flow Meter" (2014)[URL]
- "Heat flux Sensors" (1999)[URL]
- 한기철, "단열 파우더를 채용한 LNGCC의 BOR예측에 관한 연구", 한국전산구조공학회논문집, 24(2), pp.193~200 (2011), 한국전산구조공학회
- Haruyama, T., "Performance of Peltier Elements as a Cryogenic Heat Flux Sensor at Temperatures down to 60K", Cryogenics, 41, pp.335~339 (2001)
- "Thermal Conductivity and Resistance/<" (2005)[URL]
- Yang, H. C., "Development of Micro-machined Heat Flux Sensor by Using MEMS Technology", Proceedings of KSME 2004 Spring Annual Meeting, pp.1364~1369 (2004)