A Fusion Study on the Selection of Cyberknife Technique according to the Location of the Pulmonary Tumors
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Depending on the location of the lung tumor, the choice of treatment technique should be considered when treating the Cyberknife. The 4DCT images of 18 lung cancer patients were analyzed, and location error values were extracted through application program. The evaluation result was lower than the average position error only in the upper and the inner. These results suggest that the Vertebral tracking technique is effective when it is close to the pulmonary attachment or near the vertebral body, and the Synchrony technique is effective at other positions. In the future, we would like to study cyber knife treatment technique according to the position of the tumor as well as the volume of the lung and the respiratory cycle.
Abstract
Depending on the location of the lung tumor, the choice of treatment technique should be considered when treating the Cyberknife. The 4DCT images of 18 lung cancer patients were analyzed, and location error values were extracted through application program. The evaluation result was lower than the average position error only in the upper and the inner. These results suggest that the Vertebral tracking technique is effective when it is close to the pulmonary attachment or near the vertebral body, and the Synchrony technique is effective at other positions. In the future, we would like to study cyber knife treatment technique according to the position of the tumor as well as the volume of the lung and the respiratory cycle.
참고문헌 (24)
- 김용배, "특집", 방사선치료의 진화: 고정밀방사선치료, 2008, pp.51(7), 604~611[DOI]
- Philippe Giraud, "Respiratory Gating Techniques for Optimization of Lung Cancer Radiotherapy", Journal of Thoracic Oncology, 6(12), pp.2058~2068 (2011), Elsevier BV[DOI]
- T. Biswas, "SU‐E‐T‐422: Lung SBRT Using Cyberknife: Technique and Treatment Outcome", Medical physics, 39(6Part16), pp.3801~3802 (2012)[DOI]
- P. C. Gerszten, "CyberKnife Frameless Stereotactic Radiosurgery for Spinal Lesions: Clinical Experience in 125 Cases", Neurosurgery, 55(1), pp.89~99 (2004), Ovid Technologies (Wolters Kluwer Health)[DOI]
- 서선열, "중증외상환자 CT 검사 시 검사보조자의 방사선피폭 경감을 위한 융합적 망토 차폐체의 유용성 연구", 한국융합학회논문지, 8(9), pp.211~216 (2017), 한국융합학회[DOI]
- 전영준, "사이버나이프에서 Xsight spine tracking system을 이용한 3D 표적위치보정의 유용성 평가", 디지털융복합연구, 13(1), pp.331~339 (2015), 한국디지털정책학회[DOI]
- 한범희, "진단용 X선 장치에서 방사선출력의 재현성 평가(IEC 60601-2-54 표준규격을 기반으로)", 디지털융복합연구, 12(2), pp.555~561 (2014), 한국디지털정책학회[DOI]
- 이강연, "종양치료용 고주파 열치료 인체적용 시뮬레이션", 한국융합학회논문지, 9(3), pp.257~263 (2018), 한국융합학회[DOI]
- Thomas Rockwell Mackie, "Image guidance for precise conformal radiotherapy", International Journal of Radiation Oncology*Biology*Physics, 56(1), pp.89~105 (2003), Elsevier BV[DOI]
- S. Webb, "Optimization by simulated annealing of three-dimensional conformal treatment planning for radiation fields defined by a multileaf collimator", Physics in medicine and biology, 36(9), pp.1201~ (1991)[DOI]
- L Leksell, "Stereotactic radiosurgery", Journal of Neurology, Neurosurgery & Psychiatry, 46(9), pp.797~803 (1983), BMJ[DOI]
- 김정호, "Improvement of Beam-Quality Evaluation Method for Medical Linear Accelerator Using Magnetic Field", Journal of Magnetics, 20(2), pp.120~128 (2015), 한국자기학회
- Kenneth H. Wong, "Quantitative Measurement of CyberKnife Robotic Arm Steering", Technology in Cancer Research & Treatment, 6(6), pp.589~594 (2016), SAGE Publications[DOI]
- Mehrdad Sarfaraz, "CyberKnife® Robotic Arm Stereotactic Radiosurgery", Journal of the American College of Radiology, 4(8), pp.563~565 (2007), Elsevier BV[DOI]
- 김연실, "특집", 사이버나이프 로봇형 방사선수술장치를 이용한 암 치료, 2008, pp.51(7), 630~637[DOI]
- Tae Suk Suh, "Physical and Biological Background of Radiosurgery", Journal of the Korean Medical Association, 51(1), pp.16~26 (2008), Korean Medical Association (KAMJE)[DOI]
- Achim Schweikard, "Robotic Motion Compensation for Respiratory Movement during Radiosurgery", Computer Aided Surgery, 5(4), pp.263~277 (2010), Informa UK Limited[DOI]
- Kei Kitamura, "Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions", International Journal of Radiation Oncology*Biology*Physics, 53(5), pp.1117~1123 (2002), Elsevier BV[DOI]
- A. Schweikard, "Respiration tracking in radiosurgery", Medical physics, 31(10), pp.2738~2741 (2004)[DOI]
- W. Kilby, "The CyberKnife® Robotic Radiosurgery System in 2010", Technology in Cancer Research & Treatment, 9(5), pp.433~452 (2010), SAGE Publications[DOI]
- Mischa Hoogeman, "Clinical Accuracy of the Respiratory Tumor Tracking System of the CyberKnife: Assessment by Analysis of Log Files", International Journal of Radiation Oncology*Biology*Physics, 74(1), pp.297~303 (2009), Elsevier BV[DOI]
- Cihat Ozhasoglu, "Synchrony – Cyberknife Respiratory Compensation Technology", Medical Dosimetry, 33(2), pp.117~123 (2008), Elsevier BV[DOI]
- R. Shirazi, "CyberKnife stereotactic body radiation therapy for palliation and local control in patients with advanced pancreatic cancer: A retrospective review.", Journal of Clinical Oncology, 29(15_suppl), pp.e14506~e14506 (2011), American Society of Clinical Oncology (ASCO)[DOI]
- Jan-Martin Kuhnigk, "New Tools for Computer Assistance in Thoracic CT. Part 1. Functional Analysis of Lungs, Lung Lobes, and Bronchopulmonary Segments", RadioGraphics, 25(2), pp.525~536 (2005), Radiological Society of North America (RSNA)[DOI]
