초록

The trend of x-ray image sensor has been evolved from an amorphous silicon sensor toa crystal silicon sensor. A crystal silicon X-ray sensor, meaning a X-ray CIS (CMOS image sensor),is consisted of three transistors (Trs), i.e., a Reset Transistor, a Source Follower and a SelectTransistor, and a photodiode. They are highly sensitive to radiation exposure. As the frequencyof exposure to radiation increases, the quality of the imaging device dramatically decreases. Themost well known effects of a X-ray CIS due to the radiation damage are increments in the resetvoltage and dark currents. In this study, a pixel array of a X-ray CIS was made of 20×20 pixelsand this pixel array was exposed to a high radiation dose. The radiation source was Co-60 andthe total radiation dose was increased from 1 to 9 kGy with a step of 1 kGy. We irradiated thesmall pixel array to get the increments data of the reset voltage and the dark currents. Also, wesimulated the radiation effects of the pixel by MCNP (Monte Carlo N-Particle) simulation. Fromthe comparison of actual data and simulation data, the most affected location could be determinedand the cause of the increments of the reset voltage and dark current could be found.

Abstract

The trend of x-ray image sensor has been evolved from an amorphous silicon sensor toa crystal silicon sensor. A crystal silicon X-ray sensor, meaning a X-ray CIS (CMOS image sensor),is consisted of three transistors (Trs), i.e., a Reset Transistor, a Source Follower and a SelectTransistor, and a photodiode. They are highly sensitive to radiation exposure. As the frequencyof exposure to radiation increases, the quality of the imaging device dramatically decreases. Themost well known effects of a X-ray CIS due to the radiation damage are increments in the resetvoltage and dark currents. In this study, a pixel array of a X-ray CIS was made of 20×20 pixelsand this pixel array was exposed to a high radiation dose. The radiation source was Co-60 andthe total radiation dose was increased from 1 to 9 kGy with a step of 1 kGy. We irradiated thesmall pixel array to get the increments data of the reset voltage and the dark currents. Also, wesimulated the radiation effects of the pixel by MCNP (Monte Carlo N-Particle) simulation. Fromthe comparison of actual data and simulation data, the most affected location could be determinedand the cause of the increments of the reset voltage and dark current could be found.

참고문헌 (7)

  1. X선 의료영상기기 기술 및 산업동향, "허영", 93~121, pp.KEIT PD Issue Report 11(9) (2011)
  2. El Gamal, "Trends in CMOS image sensor technology and design", IEEE. Electron Devices Meeting. IEDM′02. International, pp.805~808 (2002)
  3. El Gamal A, "CMOS image sensors", IEEE. Circuits and Devices Magazine, 21(3), pp.6~20 (2005)
  4. Goiffon V, "Radiation damages in CMOS image sensors: testing and hardening challenges brought by deep sub-micrometer CIS processes. International Society for Optics and Photonics. In Remote Sensing", 78261S~78261S (2010)
  5. Gordon RH, "Radiation effects on a radiation tolerant CMOS active pixel sensor", IEEE Trans. on Nuclear Science, 51, pp.2753~2762 (2004)
  6. Tan J, "Investigation of x-ray damage effects on 4T CMOS image sensors", IEEE. In Semiconductor Conference Dresden-Grenoble (ISCDG), 2012International, pp.131~134 (2012)
  7. Wuu SG, "A high performance active pixel sensor with 0.18 μm CMOS color imager technology", IEEE. In Electron Devices Meeting 2001. IEDM′01. Technical Digest. International, pp.24~33 (2001)

관련 논문AI추천

센서-회로 분리형 엑스선 DR 검출기를 위한 대면적CMOS 영상센서 모사 연구강동욱, 김명수, 김종열, 김현덕, 김형택, 배준형, 유현준, 이대희, 조규성, 조민식(사)한국방사선산업학회 · 방사선산업학회지2012 · 제6권 제1호전송 게이트가 내장된 Gate/Body-Tied P-Channel Metal-Oxide Semiconductor Field-Effect Transistor 구조 광 검출기를 이용한 감도 가변형 능동 화소 센서최평, 권현우, 서상호, 신장규, 이제원, 장준영한국센서학회 · 센서학회지2021 · 제30권 제2호상보형 신호경로 방식의 CMOS 이미지 센서 픽셀의 하드웨어 구현권보민, 김지만, 박용수, 박주홍, 송한정, 이제원, 정진우한국센서학회 · 센서학회지2009 · 제18권 제6호몬테카를로 영상모의실험 코드를 이용한 Gd2O2S(Tb) 섬광체 및 광센서 어레이 기반 디지털 X-선 영상시스템의 화질평가김신, 김호경, 박주희, 오지은, 이봉수, 정만희, 정인범, 조효성, 한봉수대한의용생체공학회 · 의공학회지2004 · 제25권 제4호이중 샘플링 기반의 넓은 동작 범위 CMOS 이미지 센서의 동작 및 시뮬레이션을 통한 특성 분석공재성, 서상호, 신장규, 이수연, 조성현, 최경화한국센서학회 · 센서학회지2010 · 제19권 제4호출력 전압 피드백을 통한 능동 화소 센서의 동작 범위 확장공재성, 서민웅, 서상호, 신장규한국센서학회 · 센서학회지2009 · 제18권 제4호