Dose Volume Histogram Analysis for Comparison of Usability of Linear Accelerator Flattening Filter

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

The wedge filter has two movements, fixed and dynamic. In this study, the depth dose distribution was analyzed to determine the stability of the dose distribution and dose volume histograms obtained by evaluating the usability of the critical normal tissue dose around the tumor dose. The depth dose was analyzed from the dose distribution from a Linac (6 MV and 10 MV irradiation field of energy 20×20 cm2, wedge filter with a SSD of 100 cm and 15°, 30°, 45° Y1-in (Left -7 cm), Y2-out (Right +7 cm). To analyze the fluctuations of the depth dose, a fixed wedge and dynamic wedge toe portion was examined according to the energy and angle because the size of the fluctuations was included in the error bound and did not show significant differences. The neck, breast, and pelvic dosimetry in tumor tissue are measured more commonly with a dynamic wedge than a fixed wedge presumably due to the error range. On the other hand, dosimetry of the surrounding normal tissue is more common using a fixed wedge than with a dynamic wedge.

Abstract

The wedge filter has two movements, fixed and dynamic. In this study, the depth dose distribution was analyzed to determine the stability of the dose distribution and dose volume histograms obtained by evaluating the usability of the critical normal tissue dose around the tumor dose. The depth dose was analyzed from the dose distribution from a Linac (6 MV and 10 MV irradiation field of energy 20×20 cm2, wedge filter with a SSD of 100 cm and 15°, 30°, 45° Y1-in (Left -7 cm), Y2-out (Right +7 cm). To analyze the fluctuations of the depth dose, a fixed wedge and dynamic wedge toe portion was examined according to the energy and angle because the size of the fluctuations was included in the error bound and did not show significant differences. The neck, breast, and pelvic dosimetry in tumor tissue are measured more commonly with a dynamic wedge than a fixed wedge presumably due to the error range. On the other hand, dosimetry of the surrounding normal tissue is more common using a fixed wedge than with a dynamic wedge.

참고문헌 (11)

  1. Cheng CW, "A computer-aided treatment planning technique for universal wedges", Int. J. Radiat. Oncol. Biol. Phys, 13(12), pp.1927~1935 (1987)
  2. Cross P, "Tangential breast irradiation: simple improvements", Int. J. Radiat. Oncol. Biol. Phys, 23(2), pp.433~442 (1992)
  3. Cumberlin RL, "Carcinogenic effects of scattered dose associated with radiation therapy", Int. J. Radiat. Oncol. Biol. Phys, 17(3), pp.623~629 (1989)
  4. Khan FM, "Dosimetry of asymmetric x-ray collimators", Med. Phys, 13(6), pp.936~941 (1986)
  5. Kijewski PK, "Wedge-shaped dose distributions by computer-controlled collimator motion", Med. Phys, 5(5), pp.426~429 (1978)
  6. Klein EE, "Dosimetry and clinical implementation of dynamic wedge", Int. J. Radiat. Oncol. Biol. Phys, 31(3), pp.583~592 (1995)
  7. Li Z, "Suface and peripheral doses of dynamic and physical wedges", Int. J. Radiat. Oncol. Biol. Phys, 37(4), pp.921~925 (1997)
  8. Marks LB, "Use of normal tissue complication probability models in the clinic", Int. J. Radiat. Oncol. Biol. Phys, 76(3), pp.10~19 (2010)
  9. Oh YT, "Dosimetric characteristics of dynamic wedge technique", J. Korean Soc. Ther. Radial. Oncol, 14(4), pp.323~332 (1996)
  10. Petti PL, "Effective wedge angles with a universal wedge", Phys. Med. Biol, 30(9), pp.985~991 (1985)
  11. Prabhakar R, "Comparison of contralateral breast dose for various tangential field techniques in clinical radiotherapy", Technol. Cancer Res. Treat, 6(2), pp.135~138 (2007)

관련 논문AI추천

고에너지 엑스선의 선속평탄여과판이 조사야의 축이탈비 선량 변화에 미치는 영향곽종길, 김미현, 김성길, 동경래, 정묘영, 지연상(사)한국방사선산업학회 · 방사선산업학회지2019 · 제13권 제3호쐐기필터 사용에 따른 선량증가 영역에서 선량평가김연래, 김진영, 문성공, 서태석, 이정우, 정진범대한방사선과학회 · Journal of Radiological Science and Technology2014 · 제37권 제4호Evaluation of Beam-Matching Accuracy for 8 MV Photon Beam between the Same Model Linear Accelerator강성희, 김연래, 정진범대한방사선과학회 · Journal of Radiological Science and Technology2020 · 제43권 제2호고정형 쐐기(Physical wedge)와 동적 쐐기(Dynamic wedge)의 조사야 주변 선량에 관한 연구고신관, 나경수, 민제순, 박흥득, 이제희, 한동균대한방사선과학회 · Journal of Radiological Science and Technology2008 · 제31권 제4호Performance Evaluation of Stealth Chamber as a Novel Reference Chamber for Measuring Percentage Depth Dose and Profile of VitalBeam Linear Accelerator강상원, 강성희, 김경현, 김연래, 서태석, 신영주, 이정우, 정재용, 정진범대한방사선과학회 · Journal of Radiological Science and Technology2018 · 제41권 제3호쐐기필터 사용 시 레디오크로믹 필름을 이용한 조직에 따른 선량분포 연구김연래, 박병문, 박지연, 서태석, 이정우, 정재용대한방사선과학회 · Journal of Radiological Science and Technology2012 · 제35권 제2호

이 간행물의 다른 논문 (15건)