전선 케이블의 전자선 조사에서 몬테칼로 코드를 이용한 선량 계산
Dose Measurement with Monte Carlo Codes in Irradiation of Electrical Cables by Electron Beam
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The reason for crosslinking the insulation polymer in wire and cable by radiation isto improve their performance at elevated temperature, the chemical resistance, toughness, andabrasion resistance to slow crack growth. Radiation process quality depends not only on the doselevel but also on homogeneity of the dose distribution in especially circular objects like cableswhich have different density in core and insulation part, respectively. It is important to optimizecrosslinking processes to reduce the operation cost while sustaining adequate quality of the finalproduct. The computer simulation method becomes a very effective tool for optimization processproviding necessary information in short time and reducing cost in comparison with conventionalapproach based on experimental dosimetry. The availability of several Monte Carlo codes forelectron and photon transport and the advances in the performances of computing systems,make possible to tackle quantitative dosimetry tasks by numerical simulation. With increasedcomputing speed and decreasing hardware cost, it is expected that Monte Carlo based electrondose calculation algorithms will soon become available for routine electron beam dosimetry. Thecomputer simulation of the dose distributions in electric cables was performed for various processparameters, namely level of electron beam energy, irradiation positions, and density of insulatorof cable.
Abstract
The reason for crosslinking the insulation polymer in wire and cable by radiation isto improve their performance at elevated temperature, the chemical resistance, toughness, andabrasion resistance to slow crack growth. Radiation process quality depends not only on the doselevel but also on homogeneity of the dose distribution in especially circular objects like cableswhich have different density in core and insulation part, respectively. It is important to optimizecrosslinking processes to reduce the operation cost while sustaining adequate quality of the finalproduct. The computer simulation method becomes a very effective tool for optimization processproviding necessary information in short time and reducing cost in comparison with conventionalapproach based on experimental dosimetry. The availability of several Monte Carlo codes forelectron and photon transport and the advances in the performances of computing systems,make possible to tackle quantitative dosimetry tasks by numerical simulation. With increasedcomputing speed and decreasing hardware cost, it is expected that Monte Carlo based electrondose calculation algorithms will soon become available for routine electron beam dosimetry. Thecomputer simulation of the dose distributions in electric cables was performed for various processparameters, namely level of electron beam energy, irradiation positions, and density of insulatorof cable.
참고문헌 (25)
- Abe M, "Method for producing electric wire, method for producing molded article, and method for producing resin material containing modified fluororesin", US Patent No. 10,144,792, ~ (2018)
- Fabris FW, "Free radical modification of LDPE with vinyltriethoxysilane", Eur. Polym. J, 40, pp.1119~1126 (2004)
- Gheysari D, "Radiation crosslinking of LDPE and HDPE with 5 and 10 MeV electron beams", Eur. Polym. J, 37, pp.2011~2016 (2001)
- Hussain F, "Polymer-matrix nanocomposites, processing, manufacturing, and application. An Overview", J. Compos. Mater., 40, pp.1511~1575 (2006)
- Iwasaki M, "Crosslinkable halogen-free resin composition, crosslinked insulated wire and cable", US Patent No. 9,627,099, ~ (2017)
- Kaluskab I, "The features of electron dose distributions in circular objects : Comparison of Monte Carlo calculation predictions with dosimetry", Radiat. Phys. Chem, 76, pp.1815~1819 (2007)
- Kango S, "Surface modification of inorganic nanoparticles for development of organic-inorganic nanocomposites. A review", Prog. Polym. Sci., 38, pp.1232~1261 (2013)
- Khonakdar HA, "An investigation of chemical crosslinking effect on properties of high density polyethylene", Polymer, 44, pp.4301~4309 (2003)
- Kosaentor K, "Monte Carlo simulation of electron beam system for natural rubber vulcanization", Proceedings of IPAC2017, pp.4747~4749 (2017)
- Makuuchi K, "radiation processing of polymer materials and its industrial applications", pp.147~153 (2012), A John Wiley & Sons, Inc. Publication
- Mangiacapra L, "A new process simulator for the optimization of electron beam crosslinking processes of polymers isolations in electrical cables", Radiat. Phys. Chem, 84, pp.119~125 (2013)
- Martin CP, "The thermomechanical behaviour of crosslinked polyethylene cable insulation material", Proceedings of the Annual Report Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)., pp.88~91 (2003)
- Mizutani Y, "Wiring harness and connector for electric and hybrid electric vehicles", SEI Tech. Rev, 88, pp.27~31 (2019)
- Pleşa I, "Polyethylene nanocomposites for power cable insulations", Polymers, 11(24), pp.24~21 (2018)
- Rong MZ, "Surface modification of nanoscale fillers for improving properties of polymer nanocomposites. A review", Mater. Sci. Technol., 22, pp.787~796 (2006)
- Sasaki T, "Development of radiation crosslinking process for high voltage power cable", Radiat. Phys. Chem, 14, pp.821~830 (1979)
- Shokoohi S, "Silane coupling agents in polymer-based reinforced composites. A review", J. Reinf. Plast. Compos., 27, pp.473~485 (2008)
- Spencer M, "Composition distribution in poly(ethylene-graftvinyltrimethoxysilane)", Polymers, 44, pp.2015~2023 (2003)
- Steven W, "Radiation curable and cable insulation composition", US Patent No. 6,326,422, ~ (2001)
- Svoboda P, "Influence of branching density in ethylene-octene copolymers on electron beam crosslinkability", Polymers, 7, pp.2522~2534 (2015)
- Ueno K, "Radiation-crosslinked polyethylene for wire and cable applications", Int. J. Radiat. Appl. Instrum. C Radiat. Phys. Chem, 37, pp.89~91 (1991)
- Umit G, "Crosslinkable thermoplastic polyurethane", US Patent No. 9,650,477, ~ (2017)
- Zamore A, "Irradiation conversion of thermoplastic to thermoset polyurethane", US Patent No. 5,900,444, ~ (1999)
- Zimek Z, "Optimization of electron beam crosslinking of wire and cable insulation", Radiat. Phys. Chem, 81, pp.1398~1403 (2012)
- Zimek Z, "Optimization of electron beam crosslinking for cables", Radiat. Phys. Chem, 94, pp.161~165 (2014)
